Ion Technologies SEH50M-23, SEH50M-21, SEH50M-03, SEH50M-43, SEH100M-21 Operation Manual

...
SEH50-SEH100-SEH200
Heavy Duty High Head Sewage Pumps
OPERATION MANUAL
Dated: 03/22/2018 Document Name: SEH50-SEH100-SEH200_OM
Page 1 of 12
Marks & Meanings
CAUTION: Keep the pump equipment out of
the reach of children! Warns that the failure to follow the directions given could cause serious risk to individuals or objects.
WARNING: This sign warns the operator that
the failure to follow an instruction may damage the pump and/or the system.
Safety Warnings
CAUTION: Read these safety warnings rst
before installing, servicing, or operating any
pump.
Introduction
Check the nameplate for your pump’s specication,
refer to the table list.
Be careful not to exceed the given specications in
the use of your pump.
Each pump is individually factory tested to ensure proper performance. Closely following these instructions will eliminate potential operating problems assuring years of trouble-free service.
Most accidents can be avoided by using common sense.
Before Installation
This manual contains important information for the safe use of this product. Read this manual completely and follow the instructions carefully. Reasonable care and safe methods relating to the installation and operation of this product should be practiced. Check local codes and requirements before installation.
WARNING: Risk of Electrical Shock or
Electrocution. May result in serious injury or
death or re hazard. Installer must disconnect all electrical sources prior to installation, handling or servicing. Only qualied personnel may install this
system. NFPA 70/National Electric Code (NEC) or local codes must be followed. System must be properly grounded according to NEC. Do not lift pump by power cord.
WARNING: Risk of Fire or Explosion. Do not
smoke or use open ames in or around this
system. This system is not intended for use in
hazardous locations per NFPA 70 National Electric Code. Do not pump ammable liquids. Consult factory for optional equipment rated for hazardous location
use.
IMPORTANT: Ion Technologies is not responsible for losses, injury or death resulting from failure to observe these safety precautions, misuse, abuse or misapplication of pumps or equipment.
www.ionproducts.net
CAUTION: Rotating machinery,
amputation or severe lacerations can result. Keep clear of suction and discharge openings. DO NOT insert fingers into pump with power connected. Risk of serious cutting or
SEH50-SEH100-SEH200
Heavy Duty High Head Sewage Pumps
OPERATION MANUAL
Dated: 03/22/2018 Document Name: SEH50-SEH100-SEH200_OM
Page 2 of 12
amputation exists. Disconnect all power sources prior to servicing pump. Pump may start without warning.
CAUTION: Do not modify the cord and plug.
When using the cord and plug, plug into a
grounded outlet only. When wiring to a system control,
connect the pump ground lead to the system ground.
CAUTION: Do not run the pump dry. Dry running can overheat the pump (causing burns
to anyone handling it) and will void the warranty.
CAUTION: The pump normally runs hot. To
avoid burns, allow it to cool for 30 minutes after
shutdown before handling it.
CAUTION: Submersible sewage pumps are
not approved for use in swimming pools,
recreational water installations, decorative fountains or
any installation where human contact with the pumped
uid is common. Pump designed to be installed in a
sewage pit or wet location where drainage collects.
WARNING: Do not throw away or lose this
manual. Keep it in a safe place so that you may refer to it often for the continued safe operation of the product.
CAUTION: All returned products must be
cleaned, sanitized, or decontaminated prior to shipment, to insure employees will not be exposed to health hazards in handling said materials. All applicable laws and regulations shall apply.
WARNING: Bronze/brass fitted pumps may
contain lead levels higher than considered safe for potable water systems. Government agencies have determined that leaded copper alloys should not be used in potable water applications.
WARNING: Installation, wiring, and junction
connections must be in accordance with the National Electric Code and all applicable state and local codes. Requirements may vary depending on usage and location.
WARNING: Installation and servicing is to be
conducted by qualied personnel only.
CAUTION: Rotating machinery,
amputation or severe lacerations can result. Keep clear of suction and discharge openings. DO NOT insert fingers into pump with power connected.
WARNING: Always wear eye protection when
working on pumps. Do not wear loose clothing that may become entangled in moving parts.
WARNING: Pumps build up heat and
pressure during operation. Allow time for pumps to cool before handling or servicing.
CAUTION: Hazardous Voltage can shock,
burn or cause death. This pump is not
intended for use in swimming pools or water installations where human contact with pumped fluid is possible.
CAUTION: Risk of electrical shock. To
reduce risk of electrical shock, always
disconnect pump from source before handling. Lock out power & tag.
WARNING: Do not use these pumps in
water over 104°F. Do not exceed manufactures recommended maximum
performance, as this could cause the motor to
overheat.
WARNING: Make sure lifting handles are
securely fastened each time before lifting.
CAUTION: Do not lift, carry or hang pump
by the electrical cables. Damage to the
electrical cables can cause shock, burns or death.
Never handle connected power cords with wet hands. Use appropriate lifting device.
WARNING: Sump and sewage pumps often
handle materials which could cause illness or disease. Wear adequate protective clothing when working on a used pump or piping. Never enter a basin after it has been used.
CAUTION: Failure to permanently ground
the pump, motor and controls before connecting to power can cause shock, burns or
death.
www.ionproducts.net
SEH50-SEH100-SEH200
Heavy Duty High Head Sewage Pumps
OPERATION MANUAL
Dated: 03/22/2018 Document Name: SEH50-SEH100-SEH200_OM
Page 3 of 12
CAUTION: These pumps are NOT to be installed in locations classified as
hazardous in accordance with the National Electric Code, ANSI/NFPA 70.
WARNING: Do not introduce into any sewer,
either directly, or through a kitchen waste disposal unit or toilet: Seafood Shells, Aquarium Gravel, Cat Litter, Plastic Objects, Sanitary Napkins or Tampons, Diapers, Rags, Disposable Wipes or Cloth, Medications, Flammable Material, Oil or Grease, Strong Chemicals, Gasoline.
• Operation against a closed discharge valve will cause premature bearing and seal failure on any pump.
• Any wiring of pumps should be performed by a
qualied electrician.
• Cable should be protected at all times to avoid
punctures, cuts, bruises, and abrasions-inspect
frequently.
• Never handle connected power cords with wet hands.
• Never let cords or plugs lie in water outside the pit.
Performance
80
70
60
50
40
30
20
10
Total Dynamic Head (ft.)
0 20 40 60 80 100 120 140 160 180
SEH100
SEH50
Capacity (GPM)
SEH200
Dimensions
10.77"
2.91"
These pumps are o󰀨ered in a three phase and single phase wiring conguration. Voltages will
vary according to the application and can be seen in the tables in this manual.
Pump Installation
These important instructions must be followed for satisfactory performance of your pump. Before
installation, check your local electrical and plumbing
codes.
The sump or basin shall be sealed and vented in accordance with local plumbing codes. This pump is
designed to pump domestic wastewater, nonexplosive
and noncorrosive liquids and shall NOT be installed in
locations classied as hazardous in accordance with
the National Electrical Code (NEC) ANSI/ NFPA 70 or Canadian Electric Code (CEC). The pump should
never be installed in a trench, ditch, or hole with a dirt
bottom. The legs will sink into the dirt and the suction will become plugged.
20.2"
6.24"
13.1"
2” NPT Flanged Discharge 3” NPT Optional
7"
2"
www.ionproducts.net
SEH50-SEH100-SEH200
Heavy Duty High Head Sewage Pumps
Important 1 Phase Models Model Number:
Prior to installation, record Model Number, MFG Date, Amps, Voltage, Phase and HP, from pump
nameplate for future reference. Also record the voltage and current readings at startup.
Specifications
OPERATION MANUAL
Dated: 03/22/2018 Document Name: SEH50-SEH100-SEH200_OM
Amps: Volts: MFG Date:
3 Phase Models Phase:
Amps L1-2: Volts L1-2:
Amps L2-3: Volts L2-3:
Amps L3-3: Volts L3-3:
HP:
SN:
Page 4 of 12
Model HP Volt Ph
SEH50M-11 0.5 60 115/1 3450 12.0 SOW 16/3 0.43
SEH50M-21 0.5 60 230/1 3450 6.0 SOW 16/3 0.43
SEH50M-03 0.5 60 208/3 3450 4.2 SOW 16/4 0.46
SEH50M-23 0.5 60 230/3 3450 4.0 SOW 16/4 0.46
SEH50M-43 0.5 60 460/3 3450 2.0 SOW 16/4 0.46
SEH100M-21 1 60 230/1 3450 11.0 SOW 16/3 0.43
SEH100M-03 1 60 208/3 3450 6.8 SOW 16/4 0.46
SEH100M-23 1 60 230/3 3450 6.6 SOW 16/4 0.46
SEH100M-43 1 60 460/3 3450 3.3 SOW 16/4 0.46
Nema Start
Code
FLA Cord Size Cord Type
Cord O.D.
Inches
SEH200M-21 2 60 230/1 3450 18.0 SOW 14/3 0.575
SEH200M-03 2 60 208/3 3450 10.4 SOW 16/4 0.46
SEH200M-23 2 60 230/3 3450 9.0 SOW 16/4 0.46
SEH200M-43 2 60 460/3 3450 4.5 SOW 16/4 0.46
www.ionproducts.net