ion science GAS-CHECK SF6 Instruction Manual

INSTRUCTION MANUAL
GAS-CHECK SF
6
AN INSTRUMENT FOR THE LOCATION AND
MEASUREMENT OF LEAKS IN SF6 FILLED
User Manual iss 01 Software-Version V1.39BB
Page 1
Contents: Software version V1.39BB
Subject Description Page
3.0 General 2
3.1 Safety 2
4.0 System Properties/introduction 3
4.1 Console controls 3
5.0 Handgun displays and controls 4
5.1 Handgun analogue display 4
5.2 Handgun display LED’s 4
6.0 Handgun buttons 5
6.1 Top Caps 5
6.2 Filters 5
7.0 Getting started 6
7.1 Measuring operation 6
7.2 Possible fault conditions during operation 6
7.3 Low flow error 7
7.4 Flare stall 7
7.3 Low battery voltage 7
7.5 Switching OFF 7
8.0 Switching OFF in case of fault 7
8.1 User setup 8
8.2 Set volume/Contrast 8
9.0 Open Operator Level 8
9.1 Operator ID 8
9.2 Data printout 9
9.3 Clear data memory 9
9.4 Open Supervisor Level 9
9.5 Set alarm levels 9
9.6 Operator ID mode 9
10.0 Do not force operator ID 9
10.1 Force operator ID by name 9
10.2 Force operator ID by key code 10
10.3 Access codes 10
10.4 Changing passwords 10
10.5 Terminate and lock supervisor level 10
10.6 Open Tech level 10
11.0 Calibration 11
11.1 Set clock 11
Page 2
12.0 User setup 12
12.1 Peak hold (gauge) 12
12.2 Peakhold (screen) 12
12.3 Display units 12
13.0 Desen Factor 1 13
13.1 Desen Factor 2 13
13.2 Standby mode 13
14.0 Standby delay 13
14.1 RS232 Protocol 13
14.2 Sound type 14
14.3 Sound begins at 14
14.4 Live tick 14
14.5 Filter threashold 14
14.6 Filter count 14
15.0 Tech data readout 14
15.1 Probe/Sensor/Filter life 15
15.2 Changing the Probe 15
16.0 Known problems. 15
16.1 Power Up During Transport. 15
16.2 Power Up after fuse has been removed 15
16.3 Pre set passwords on delivery 15
16.4 Settings on despatch 16
16.5 Citizen printer 16
16.6 Spares and consummables 16
3.0 GENERAL:
This manual is addressed to those responsible for and using this instrument and applies to software version V1.37BB
3.1 SAFETY:
Please read this paragraph carefully before operating the instrument. Do not open any part of the instrument, there are no user-serviceable parts inside. Protect from moisture and water. Use in dry conditions. Use only to leak test on voltage-free and grounded switchgear. Touching a finger gently to the screen surface operates the touch screen.
DO NOT USE TOOLS TO TOUCH THE SCREEN.
Page 3
4.0 SYSTEM PROPERTIES: Introduction:
GAS-CHECK SF6 is a portable, mains-independent instrument for leak detection and leak measurement of SF6 gas. Although designed for SF6, other gases with a high affinity for electrons, such as refrigerant R12 may also be detected.
Although designed for operation without training, we recommend that this manual be read before use. This manual and the instrument have been designed to be understood by users whose first language is not English. Please advise us of any changes, which will make this easier.
Two modes of operation are available, volume loss/time cc/sec (leak-detection) and (ppm) concentration of SF6 in air.
All controls and displays required for detection are found in the hand unit. Accurate and clear measurement is achieved from the console touch screen display.
Measurements can be stored in the instrument and later transferred to a printer or computer. A battery-powered printer is available. Results may also be downloaded to a computer via the RS2323 link.
The only item, which needs to be replaced in normal use, is the ‘Smart Sensor’ probe. Smart Sensors contain a microchip programmed with specific sensor information. At Switch ON, the console automatically reads sensor information.
Smart Sensors are not radioactive and contain nothing harmful. Life is approximately 200hours. Sensors are changed by switching OFF the instrument and plugging in a replacement. Three (3) are supplied and available as exchange items.
The operation of the instrument and sensor require permanent and precise control by software. Any faults give immediate error messages, which are then displayed on the touch screen. This in conjunction with the sample flow monitoring function, ensures the instrument reliably determines and displays all fault conditions.
All vital user parameters are password protected against unauthorised entry. Access to the touch-screen is required for set-up only. If used outside or in difficult
conditions the transparent cover over touch-screen can be left locked.
4.1 CONSOLE CONTROLS:
1 Touch-screen for numeric leak rate display and parameter entry. Two red on/off buttons located at the front and right side panel. Both are lit when the
instrument is on. White light combines mains supply and battery charge control. This flashes while on charge and is permanently on when the battery is full.
A Key allows the transparent front cover to be locked during use.
Page 4
5.0 Handgun Displays and Controls:
%
A
l
a
r
m
O
F
F
90
80
70
60
50
40
30
20
10
0
The following controls are found on the hand unit:
5.1 Analogue gauge: displays the response to leaks in %, rather than an absolute value (displayed on the touch-screen), and shows the leak rate in the form of a percentage of the alarm value. This is clearer and easier for an operator.
5.2 Handgun Six LEDs indicate status.
COLOUR No DESCRIPTION
Green
1
READY TO MEASURE. Normal operation. If ON, you may confidently measure. This is OFF whenever the instrument is in standby or programming mode, error condition, or the
actual reading is above 20% of the alarm level.
Red
2
NOT READY. This light is on whenever the instrument is in the programming mode, or an error condition exists. It flashes during standby mode.
Green
3
SPECIAL. Desensitise functions, flashes when one of them is active.
Yellow
4
SIGNAL. Switches on whenever a reading above 20% alarm level was taken. Reset by STORE or CLEAR key.
Red
5
ALARM. This light is on as long as a reading equal to or above the alarm level is taken.
Yellow
6
MESSAGE. Prompts the operator to read a message that is present on the LCD screen.
Page 5
6.0 HANDGUN BUTTONS:
SQUARE: This has two functions: MEASURE MODE and SEARCH (bar graph) MODE. On power-up the SEARCH mode is automatically selected, the touch screen displays a bar graph. This is ideal for fast and ultra low-level leak detection (~10 E-8cc/sec). In this mode high accuracy is not possible, just leak detection and location.
When a leak is discovered, the audible alarm sounds and the bar graph as well as the handgun analogue gauge responds, usually full scale.
To change from SEARCH to MEASURE mode, press and hold the SQUARE button for 2 seconds, the RED light comes on and the display changes to 0.00. You are now in the MEASURE high accuracy mode. If you have selected ‘Peak Hold Console’ leaks will be measured and held ready for printing if required.
Pressing SQUARE once gives desensitise x1. The second press gives desensitise x2, as pre set in USER SET-UP section in touch-screen. The LED marked SPECIAL flashes slowly with x1, and faster with x2.
CIRCLE: This zeroes and cancels desensitise and may be used at any time. During the short zero time the lights change from RED to GREEN. Do not leak test during this time.
During normal use it is recommended to press the CIRCLE key occasionally to zero the detector to ambient conditions.
TRIANGLE: The RESULT STORE key. The peak reading shown on the touch-screen is transferred to memory for later printout.
6.1: TOP CAPS: A choice of top caps are available, Standard (P1-100-0003),
extended (P1-100-0004), and extended with a Stainless Steel tip (P1-100-0005). This has a 5mm diameter and is designed for leak searching in enclosed spaces or where rough (welded) surfaces must be checked.
6.2 FILTERS: It is essential that FILTER (P1-100-0005) is always fitted. This
provides a small micron filter and provides a seal for the secondary sinter. This sinter forms part of the detector vacuum cell and is critical to good stable and accurate operation. The flow down the top cap past the filter and into the vacuum chamber is constantly monitored. The vacuum automatically compensates for filter restriction, to a point when accuracy is threatened. At this time the LOW FLOW ERROR is displayed and the filter should be changed.
All these items are available ex stock from ISL or your local agent.