TROUBLE-SHOOTING
DEEP CLEANING
Noisy functioning (audible lou d buzzing sound) is a sign that
your Ionic Pro® Compact ionic air purifier is overdue fo r a co mplete
clean-up of the collection blades and the internal ionizing wires.
The internal ionizing wires must be kept cl ean to ensure silent
and normal operation.
To Deep Clean:
1. Before be ginning, make sure you have read all of the safety
precautions and cleaning instruc tions located in the “SAFETY
INSTRUCTION”, “IMPORTANT WARNINGS”, and “CLEANING
& MAINTENANCE” sections of this owner ’s manua l.
2. First, turn O FF and unplug your Ionic Pro® Compact ionic
air purifier.
3. Let it rest for a minute b efore removing the collection blades
as described in the “To Clean the Collectio n Blades” section of
this manual.
4. Use a cloth and warm, suds y water to wipe away dirt particles
on the blades’ surfaces and edges.
5. R inse and let the blades dry thoroughly for 24 hours before
re-inserting the m into your Ionic Pro® Co mpact ionic air purifier.
If desired, you can purchase a second se t of collection blades to
use while the original blades are dr ying to allow for virtually
uninterrupted air purification. (See the “O RDERING EXTRA
COLLECTION BLADE S” section of this owner’s manual for details.)
6. Clean the ionizing w ires as described in the “To Clean the Ionizing
Wires” section of this manual.
Cleaning External Surfaces
Over time, some particles an d dust may accumulate on the
external surfa ces o f yo ur Ionic Pro® Co mpact ionic air purifier.
If this happens:
1. Turn off and unplug the unit.
2. Mix one ounce of so ap or detergent with five ounces of water
and apply sparingly with a moist sp onge to wipe the outer
case surfaces.
3. Do not allow any water to slip into the internal par ts of the Ionic Pro®
Compact ionic air purifier as this could dam age its functioning and
may result in injury to you.
4. Allow the unit to dr y for at least 24 hours before resuming use.
CLEANING & MAINTENANCE
TROUBLE REASON TROUBLE-SHOOTING
Indication/Setting light
does not turn on .
Machine is unplugged.
ON/OFF button has not
been pressed.
Check if plug is loose.
Press the ON/OFF button.
Red CLEAN light i s on or
the unit shuts down.
Too much dust has
accumulated.
AC input unstable or
overloaded.
Moisture on collection blades.
Red light may go on if the unit
just needs to be “reset”.
Turn off, unplug & lift the lever
to the wire cleaning mechanism
to clean the ionizing wires.
Turn off, allow unit to rest
a while to return to normal.
Temperature & moisture level
and then turn on again.
Press “ON” button to reset.
Excessive noise
generated.
Collection blades are not
installed properly.
Too much dust has
accumulated.
Internal parts are wet.
Remove & replace collection
blades & press “On” button.
Clean and dry blades and
ionizing wires thoroughly.*
Keep the machine dry.
Collection blades
do not go back in.
Improper orientation. Reverse blade orientation.
Indication light
does not go on.
Collection blades are not
completely inserted
Wire Cleaning Mechanism is
not completely inserted.
Check to see that the blades are
completely seated in housing
Check to see that Wire Cleaning
Mechanism is completely seated
in housing.
*See “CLEANING & MAINTENANCE” section.