NOTE: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if
not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected.
—Consult the dealer or an experienced radio/ TV technician for help.
Changes or modifications not expressly approved by the party responsible for
compliance could void the user‘s authority to operate the equipment.
You are cautioned that any change or modifications to the equipment not
expressly approve by the party responsible for compliance could void your
authority to operate such equipment.
The manufacturer is not responsible for any radio or TV Interference caused by
unauthorized modifications to this equipment. Such modifications could void the user's
authority to operate the equipment.
The antenna(s) used for this transmitter must not be co-located or operating in
conjunction with any other antenna or transmitter
This device complies with part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) This device may not cause
harmful interference, and (2) this device must accept any interference
received ,including interference that may
cause undesired operation.
2
Page 3
Gemini MI (P)
ⅠSCOPE
The purpose of this specification is to define the electrical and
mechanical characteristics of the “ Gemini MI P “.
Ⅱ GENERAL
Description
The “Gemini MI P” keyboard and Mouse Combination has an
enhanced NetMedia design and can work with any IBM PC
PS/2 compatible computer. Utilizing the latest in rubber
mechanical key switch technology, the Scorpius MVII offers
durability and style that will enhance any system for years to
come. 16 Extra rubber buttons let keyboard link more closer
with PC, touch one button to make some functions work
immediately.
Features
•Radio Frequency technology
•Netmedia for easy Internet and Multimedia control
•Low power consumption
•800dpi resolution
•High quality Rubber-Membrane key switches
•Tactile key stroke
•1,000,000 life cycles per switch
•104,105,106,107,109 key layout
Package Contents:
˙Color box
˙Pcs /Carton: 10pcs
˙Package contents
- RF Keyboard
- RF Mouse
- Receiver
- 3AA & 2AA batteries
3
Page 4
Gemini MI (P)
- User Manual
System requirements
• Designed to work with IBM PC compatible
• Perfected for using with Windows® 98SE / 2000 / ME /
XP.
Ⅲ Electrical specification
Environmental of Temperatures
Operating temperature 0℃ to 50℃.
Non-operation temperature -10℃ to 60℃.
Humidity Test
Condition temperature 25C~55C
Operating humidity 10% to 85%
Non-operation Humidity 10% to 85%
Heat storage 60℃, 24Hours
Switch Life 1,000,000 cycle life
Performance specification/ Mouse
X,Y Encoder Solid-State Optical Mouse Sensor
Scroll Encoder Mechanical
Switch Life 1,000,000 cycle life
Scroll Encode Life 100,000 cycle life
Hardware Resolution 800dpi
Power Requirements
Keyboard
Voltage
Working Mode 3V 7mA
Sleeping Mode 3V 0.14 0.1mA 0.06
Power Consumption Mode Operation
Max Nom Min
Operation voltage 2V~4.5V
Mouse
Working Mode 3V 40mA
Sleeping Mode 3V 4mA 0.2mA 0.01mA
Operation voltage 3.5V~1.5V
Power Consumption 30mA Receive
Operation Voltage 5Vdc+5%
EMI / EMC
FCC ID Keyboard: F2QRFCOMBOSCM7ITR
Mouse: F2Q96C96001M7
CE 1.EN55022: 1998 Class B
2.EN 301 489-3
3.EN 300 220-3
4
Page 5
Gemini MI (P)
4.IEC 60 950:1991+A1+A2+A3+A4+A11
5.EN 60 950:1992+A1+A2+A3+A4+A11
BSMI CNS13438 乙類.
Environmental of electrical
Shock test The mouse shall withstand a shock equal to 20G
forces, half sine wave for 11 msec duration in all
three (3) orthogonal axes.
Drop test (unpackage) Drop the mouse from 60 cm height above a wood
board 15mm thick placed on a concrete floor, 3
times in th e s ame direction.
Ⅳ Mechanical specification
MaterialKeyboard Mouse Receiver
Cover HIPS PC HIPS
Key top ABS ABS HIPS
Body Weight & Dimension Keyboard Mouse Receiver
Weight 800g 100.5grams 88.5grams
Length 475.5mm 130.1mm 102.8mm
Width 172mm 73.1mm 82.2mm
High 32mm 39.5 mm 30.3mm
Body colors Keyboard Mouse Receiver
Upper color Black Black Black
Lower color Black Black Black
Key color Black 6U Silver(877c) Left and Right key color - Silver(877c) Roller color - Cool Gray Cable color - - Black
Windows - - Black
Rubber key color Grey Grey Grey
Model Label color White White White
Rubber/ Membrane
Rubber Dome contact
Resister
Membrane Contact
Resister
Membrane Open Resister 10MΩ
Play/Pause : Instruct the CD/VCD/DVD player to the previous
Previous Track : Instruct the CD/VCD/DVD player to the previous
Next track : Instruct the CD/VCD/DVD player to the next track
Home: Back to web home page
Favorites: Open My favorite after into Internet browser
Stop: Stopping web download current web Page
9
Search: Search particular web sites
⊥ Back : Back to the last page on Internet browser
_ Forward: Forward to the next page on Internet browser
: Open Default E-mail application
track
track
application
6
Page 7
Gemini MI (P)
Ⅵ Cable specification
Connector Pin Assignments
The standard connector pin out for PS/2 is as follows:
DESCRIPTION SIGNAL PINS CONNECTOR
Keyboard Date +5Vdc Signal 1
NC NC 2
Ground 0 3
Power Supply +5Vdc 4
Keyboard Clock +5Vdc Signal 5
NC NC 6
7
Page 8
Gemini MI (P)
Ⅶ RF SPEC
Keyboard Mouse Receive
FREAUENCY 27.095MHZ 27.045MHZ 26.64MHZ/26.59MHZ
MODULATION FSK FSK FSK
ID 256 256 256
DATA RATE 4.8K 4.8K 4.8K
POWER LEVEL 0 dB 0 dB
SENSITIVITY -90 dBm
TRANSISSION
DISTANCE
1.5M 1.5M 1.5M
8
Page 9
Gemini MI (P)
New key codes for scan set 1:
New key Make Break
LWIN E0 5B E0 DB
RWIN E0 5C E0 DC
APP E0 5D E0 DD
N-CHG(131) 7B FB
GHG(132) 79 F9
ROMA(133) 70 F0
K14 7D FD
K56 73 F3
K107 7E FE
KL F1 X
KR F0 X
POWER E0 5E E0 DE
SLEEP E0 5FF0 DF
WAKE UP E0 63E0 E3
New key codes for scan set 2:
New key Make Break
LWIN E0 1F E0 F0 1F
RWIN E0 27 E0 F0 27
APP E0 2F E0 F0 2F
N-CHG(131) 67 F0 67
GHG(132) 64 F0 64
ROMA(133) 13 F0 13
K14 6A F0 6A
K56 51 F0 51
K107 6D F0 6D
KL F1 X
KR F2 X
POWER E0 37 E0 F0 37
SLEEP E0 3FE0 F0 3F
WAKE UP E0 5E E0 F0 5E
New key codes for scan set 3:
New key Make Break
LWIN 8B F0 8B MAKE/BREAK
RWIN 8C F0 8C MAKE/BREAK
APP 8D F0 8D MAKE/BREAK
N-CHG(131) 85 F0 85 MAKE
GHG(132) 86 F0 86 MAKE
ROMA(133) 87 F0 87 MAKE
K14 5D F0 5D TYPEMATIC
K56 51 F0 51 TYPEMATIC
K107 7B F0 7B TYPEMATIC
KL F1 X
KR F2 X
POWER X X
SLEEP X X
WAKE UP X X
9
Page 10
Gemini MI (P)
Ⅷ Physical
10
Page 11
Gemini MI (P)
11
Page 12
Gemini MI (P)
Ⅸ SETUP GUIDE
Insert Batteries
Insert provided batteries in mouse and keyboard. Refer to diagram inside
battery compartment.
12
Page 13
Gemini MI (P)
Setup for linkage
Reset ID before using
Step 1: Connect the receiver to your computer
Step 2: Push the button on the back of the mouse (in upper left corner).
Step 3: Push the “CONNECT” button on the receiver. Please note that this
step must be completed after Step 2 within 8 seconds.
Step 4: Move pointer, when the receiver and the mouse are connected,
the LED will blink, the setting has been completed.
Step 5: Please go back to Step 2 if the LED does not behave as that in
Step 4.
Step 6: Push the button on the back of the keyboard (in upper left
corner).
Step 7: Push the “CONNECT” button on the receiver. Please note that this
step must be completed after Step 6 within 8 seconds.
Step 8: Push “Space” key, when the receiver and the keyboard are
connected, the LED will blink, the setting has been completed.
Note: If same ID is used by other users and causes interference, just
repeat this reset procedure.
13
Page 14
Gemini MI (P)
Software Installation
Turn on your computer and run either Windows 98SE / 2000 / ME / XP.
1. Insert the CD-ROM into the driver and first setup screen will appear. (If
setup does not run automatically, click Start, the Run and run “Auto
Run.exe”.) Click on “OK” to start setup. (Below is the setup process.
Please follow the screens.)
2. To perform the “NetMeida key functions setting”, you have to select
“Keyboard”.
3. To perform the “Programmable function setting” for mouse, you have
to select “3 Buttons Mouse”.
4. After installation is completed. Please re-start the computer.
14
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.