Iomega 1562, DataSafe Installation Manual

©2001 Iomega® Corporation. All Rights Reserved. Iomega is a registered trademarks of Iomega Corporation. DataSafe™ and QuikSync™ are trademarks of Iomega Corporation. Other product, company names and logos are trademarks or registered trademarks of their respective owners. Part Number: 000001562
Technical Support is available at 1-888-4-IOMEGA (1-888-446-6342) and at www.iomega.com/support/nav_techemail.html
DataSafe NAS
About This Guide- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - i
Who Should Use This Guide- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - i Box Contents - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - i Overview- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - i System Information - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ii Typographical Conventions - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ii Related Documents - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ii
1 Pre-Installation Planning - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1
Equipment Required for Installation - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1 Site Planning - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1 Familiarizing Yourself with Your DataSafe NAS - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3
2 Installing the DataSafe NAS - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4
Connect DataSafe NAS to Your Network- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4 Turning on the Power - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -4 Installing DataSafe Wizard Software - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -5 Completing DataSafe Wizard Installation - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6
3 Configuring Your DataSafe NAS - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 9
First Login- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 9 Network Setup - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10 Setting Time & Date - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13 Notes for Advanced Users - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 15 System Reboot- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 15
Index- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 17
About This Guide
Who Should Use This Guide
This DataSafeTM NAS Installation and Configuration Guide is intended to help setup and configure DataSafe NAS. It assumes that you are somewhat familiar with networking and system administration basics. Should you encounter any difficulties during the installation and configuration process outlined in this guide, please refer to the DataSafe NAS User’s Manual also found on the DataSafe NAS CD.
Box Contents
n DataSafe NAS file server n Quick Install Guide n DataSafe NAS End User License Agreement n Power Cord n CAT-5 Ethernet Cables (2) n Mounting ears (pre-installed) n Rubber feet (4) n DataSafe NAS CD containing:
• DataSafe Wizard for Setup and Discovery
• DataSafe NAS documentation
n Iomega QuikSync
TM
automatic client backup software CD
Overview
Your DataSafe NAS comes ready to install with all the required software. It works in a 10/100 Mbps Ethernet network (or Gigabit Ethernet network when so equipped), and is administered using an Internet Explorer web browser. It includes DataSafe Wizard, Iomega’s software utility that helps you locate the unit on your network, configure DataSafe NAS network settings, and launch the web user interface.
About This Guide i
DataSafe NAS
System Information
Please record the following information from the label on the side panel:
n Model Number: __________________________________________ n Serial Number: ___________________________________________ n Assembly Number: ________________________________________
These numbers will be needed by support personnel if you should contact them.
Typographical Conventions
The following typographical conventions are used in this guide to help you locate and identify information:
Table 1-1. Typographical Conventions
Item Symbol Description
Italic text is used for emphasis and book titles.
Bold text identifies menu names, menu options, items you can click on the
screen, and keyboard keys.
Courier font
NOTE:
identifies file names, folder names, and text that either appears on the screen or that you are required to type in.
Notes provide extra information, tips, and hints regarding the topic.
Cautions identify important information about actions that could result in damage to or loss of data or could cause the system to
CAUTION:
behave in unexpected ways.
Warnings identify critical information about actions that could result in unexpected equipment failure, loss of critical operating
WARNING:
system files or potential bodily injury.
Related Documents
Following is a list of related publications for background and additional information:
n DataSafe NAS User’s Manual n Quick Install Guide n DataSafe NAS End User License Agreement (EULA) n Warranty Statement n Also see our Web site at: http://www.iomega.com for latest Release Notes.
About This Guide ii
1 Pre-Installation Planning
Equipment Required for Installation
To connect, install and administer your DataSafe NAS, you will need an available 10/100 Ethernet network hub or switch. It will be necessary for your workstation to have the following capabilities:
• Windows 95/98/Me/NT (SP5)/2000
• Internet Explorer v4.01 SP1 or newer - support for Netscape is not currently available.
• Client for Microsoft Networks enabled over TCP/IP.
• Network Interface Card (NIC)
• CD-ROM Drive
Site Planning
When planning a site to house your DataSafe NAS, you will want to consider requirements for power and network availability, as well as a space with well regulated temperature and humidity that is relatively free of dust and other air-born contaminants. If your installation calls for placement on a table top, apply the enclosed rubber feet to the bottom of the chassis.
The following tables are designed to help you plan your DataSafe NAS installation.
Table 1-1. Size & Weight
Item Quantity
Weight 27 pounds (12.3 kg) Size 17 x 20 x 1.75 (43.2 x 50.8 x 4.5 cm)
CAUTION: When placing your DataSafe NAS in rack mount mode, make sure you
maintain proper mechanical load leveling to avoid a hazardous condition.
Pre-Installation Planning 1
Iomega DataSafe NAS
Table 1-2. Electrical Requirements
Item Quantity
Voltage Range 95 ~ 135 VAC or 180 ~ 265 VAC Frequency 47 ~ 63 Hz
WARNING Make sure your site has the necessary capacity to handle your DataSafe
NAS unit(s). Overloading electrical supply circuits is extremely hazard­ous. Care should also be taken to properly ground all rack mounted equipment.
Table 1-3. Operating Environment Requirements
Item Quantity
Temperature - Operating Temperature - Non-Operating
Humidity - Operating Humidity - Non-Operating
CAUTION: When mounting your DataSafe NAS in a rack system, make sure that the air
vents do not become blocked. Also, care must be taken to insure that DataSafe NAS is installed in an environment compatible with the ambient temperatures stated in the table above. Maximum of 40º C.
41º to 104º F (5ºC to 40º C) external operating temperature range
-4º to 140º F (-20ºC to +60ºC) 5% to 85% humidity non-condensing
5% to 95% humidity non-condensing
Pre-Installation Planning 2
Loading...