+44 (0)1938 556868 | sales@invertek.co.uk www.invertek.co.uk
OPTIDRIVE PLUS 3
GV
3rd Generation Vector Control
AC Variable Speed Drive
0.37kW – 160kW (0.5 – 250HP)
200 – 600V
200% torque down to 0.0Hz, reliable
high speed operation and infra red
communication
Optidrive Plus 3GV is the natural evolution of the Optidrive family
adding ultimate motor control to established Optidrive benchmarks
of control and ease of use.
Optidrive Plus 3
motor control strategy. 3
to 0.0Hz allowing this unique open loop product to be used without
any feedback device in many traditional closed loop applications.
Only the motor name plate data is required to achieve optimum
performance, the drive continuously and automatically determines
and tracks the key motor characteristics required for vector control.
Optidrive Plus 3
PDA software designed for use on pocket pc’s. Communication takes
place without wires using infrared light to quickly and accurately
transfer data.
Key Benefits
Compact Design for reduced panel space requirements•
Easy Key Mounting Slots giving fast and easy installation•
Pluggable Control Terminals enable simple, easy access control •
wiring
Up to 50°C Ambient Temperature, rugged design for harsh •
environments
Internal RFI Filter for compliance with the latest EMC standards•
14 Basic Parameters allow fast commission with powerful yet •
simple features
High Visibility LED Display with user scaling, easy to read•
32kHz Output Switching Frequency for ultra quiet motor •
operation
150% Overload for 60 Seconds (175% for 2 seconds), high starting •
capacity for demanding applications
Mains dip ride through allows continuous operation through short •
periods of supply loss
Built in Master—Slave control function with fast set up and •
selectable scaling
Built in Infra Red programming port requires no cables•
GV
uses 3GV technology, a revolutionary and patented
GV
technology delivers 200% torque down
GV
can be commissioned using the unique Optiwand
Industry Sectors
Plastics•
Machine Tools•
Rubber•
Cranes•
Pumping•
Elevators•
Chemical•
+44 (0)1938 556868 | sales@invertek.co.uk www.invertek.co.uk
Specification OPTIDRIVE PLUS 3
Output Ratings Overload capacity 150 % for 60 secs; 175 % for 2 secs
Frequency 0…500 Hz
Input Ratings Frequency 48 – 62 Hz
200 – 240V ± 10 % 1 Phase (0.37 – 22kW / 0.5 – 30 HP)
200 – 240V ± 10 % 3 Phase (1.5 – 90kW / 2– 120 HP)
Voltage
Ambient Conditions Temperature Operating: ¯10 to 50°C max; Storage: ¯40 to 60°C
Altitude
Ingress protection IP20; Optional IP55
Programming Keypad Yes
PC Yes
PDA Yes
Control Specification
Programmable I/O Input 1 Programmable Digital Input
Keypad Display Operating display Output Frequency, Current, RPM, Power and User Scalable values
Motor Feedback Feedback type With Encoder Module — HTL or TTL
Protective Functions
Bus Communication Modbus RTU Standard
Standards Compliance
Additional Features Built-in Master—Slave operation mode
Control method
PWM Frequency 4…32 kHz (effective)
V / Hz ratio Linear (1 adjustment point)
Boost Automatic after autotune
Stop mode Coast / Ramp / DC Brake
Internal brake transistor Yes (sizes 2 – 6); External resistor required
Capacity 100 % Drive Rated Power continuously
Skip frequency One point, adjustable frequency band
Frequency setpoint control
Preset speeds 8
PI control Yes
Spin start Yes
Acceleration 0…3000 secs
Deceleration (2 ramps) 0…3000 secs
S Curve accel/decel Firmware Download Available
PC setup software Optistore V3
Input 2 / Output 2 User-selectable Digital Input / Output
Input 3 User-selectable Uniploar Analogue / Digital Input
Input 4 User-selectable Biploar Analogue / Digital Input
Output 1 Programmable Analogue / Digital Output
Relay 1 Relay Output (30V DC 5A, 250V AC 6A)
Remote mount Optional Optiport Plus remote mounting keypad
Pulses / Rev Adjustable
Max. Frequency 500 kHz
Inverter trip
Memory Last 4 trips stored
Profibus DP via Gateway
DeviceNet via Gateway
RS485 (Optibus) Standard
EN 61800-3:2004
380 – 480V ± 10 % 1 Phase (0.75 – 90kW / 1 – 105 HP)
380 – 480V ± 10 % 3 Phase (1.5 – 160kW / 2 – 250 HP)
480 – 525V ± 10% 3 Phase (55 – 200kW)
500 – 600V ± 10% 3 Phase (1.5 – 45kW / 2 - 60HP)
0 – 2000 m
(derate 5% per 100 m above 1000 m)
V / F
GV
3
Sensorless Vector
Closed Loop Vector (with optional encoder feedback interface)
0…10V DC
± 10V DC
0…24V DC
4…20mA
0…20mA
Digital – Keypad
RS485 (Master Slave)
Modbus RTU
Over voltage, over current, under voltage, external trip, motor
overload, over temperature, short circuited, earth fault
Adjustable speed electrical power drive sytems. EMC
requirements.
PID ‘Sleep’ mode
Energy Optimising Function
GV