FLOOR/CEILING TYPE
MODELS:
V4MKI-24UR/U4MRS-24 V4MKI-36UR/U4MRS-36
Owner’s Manual
Indoor Unit Parts and Major Functions
.......... 06
Manual Operations ................................................... 08
SAFETY
FIRST
Safety Precautions .................................................... 04
1
2
3
Page 3
Care and Maintenance ............................. 09
a. Unit Maintenance ....................................... 09
b. How to Clean the Air Filter ....................... 09
c. Repairing Refrigerant Leaks ...................... 10
d. Preparation for Periods of Non-use ........ 10
Troubleshooting................................. 11
a. Common Problems ........................... 11
b. Troubleshooting Tips ........................ 12
European Disposal Guidelines .............................................................. 14
4
5
6
C au t i o n: Ri sk o f fi re/ fl am m ab l e ma t e r ial s
WARNING: Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants. For more details ,please refer to the Information on servicing on INSTALLATION MANUAL .(This is only required for the unit adopts R32/R290 Refrigerant)
Page 4
Thank you for purchasing this air conditioner. This manual will provide you with information on how to operate, maintain, and troubleshoot your air conditioner. Following the instructions will ensure the proper function and extended lifespan of your unit.
Please pay attention to the following signs:
Safety Precautions
1
General
Introduction
Failure to observe a warning may result in death. The appliance must be installed in accordance with national regulations.
.
Failure to observe a caution may result in injury or equipment damage.
WARNING
CAUTION
Safety
Precautions
WARNING
Ask an authorized dealer to install this air
conditioner. Inappropriate installation may cause water leakage, electric shock, or fire.
The warranty will be voided if the unit is not
installed by professionals.
If abnormal situation arises (like burning
smell), turn o the power supply and call your dealer for instructions to avoid electric shock, fire or injury.
DO NOT
let the indoor unit or the remote control get wet. It may cause electric shock or fire.
DO NOT
insert fingers, rods or other objects into the air inlet or outlet. This may cause injury, since the fan may be rotating at high speeds.
DO NOT
use a flammable spray such as hair spray, lacquer or paint near the unit. This may cause fire or combustion.
Do not use means to accelerate the
defrosting process or to clean, other than those recommended by the manufacturer.
The appliance shall be stored in a room
without continuously operating ignition sources (for example: open ames, an operating gas appliance or an operating electric heater).
The appliance shall be stored so as to
prevent mechanical damage from occurring.
Be aware that the refrigerants may not
contain an odour.
Compliance with national gas regulations
shall be observed.
Keep ventilation openings clear of obstruction.
DO NOT
pierce or burn.
NOTE:
The following informations are required
for the units adopt R32/R290 Refrigerant.
A warning that the appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as specied for operation.
Any person who is involved with working on
or breaking into a refrigerant circuit should hold a current valid certicate from an industry-accredited assessment authority, which authorises their competence to handle refrigerants safely in accordance with an industry recognised assessment specication.
Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of ammable refrigerants.
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualied persons in order to avoid a hazard.
Page 5
Safety
Precautions
CAUTION
DO NOT touch the air outlet while the swing
flap is in motion. Fingers might get caught or the unit may break down.
DO NOT inspect the unit by yourself. Ask an
authorized dealer to perform the inspection.
To prevent product deterioration, do not use the air conditioner for preservation purposes (storage of food, plants, animals, works of art, etc.).
DO NOT operate the air conditioner with
wet hands. It may cause electric shock.
DO NOT touch the evaporator coils inside
the indoor unit. The evaporator coils are sharp and may cause injury.
DO NOT place items that might be aected
by moisture damage under the indoor unit. Condensation can occur at a relative humidity of 80%.
DO NOT
expose heat-producing appliances to cold air or place them under the indoor unit. This may cause incomplete combustion or deformation of the unit due to the heat.
After long periods of usage, check the
indoor unit to see if anything is damaged. If the indoor unit is damaged, it may fall and cause injury.
If the air conditioner is used together with
other heating devices, thoroughly ventilate the room to avoid oxygen deficiency.
DO NOT
climb onto or place objects on top of the outdoor unit.
DO NOT
operate the air conditioner when using fumigant insecticides. The chemicals may become layered with the unit and endanger those who are hypersensitive to chemicals.
DO NOT
let children play with the air conditioner.
DO NOT
operate the air conditioner in a wet room (e.g. bathroom or laundry room). This can cause electrical shock and cause the product to deteriorate.
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
An all-pole disconnection device which has at least 3mm separation distance in all pole and a residual current device (RCD) with the rating of above 10mA shall be incorporated in the xed wiring according to the national rule.
The appliance shall be installed in accordance with national wiring regulations.
The indoor unit must be installed 2,5m above oor.