INVENTOR N1MVI-09WiFiR, N1MVI-12WiFiR, N1MVO-09, N1MVO-12 User Manual

English/Ελληνικά/ Română
Σας ευχαριστούμε που επιλέξατε τη μονάδα κλιματισμού της INVENTOR. Για τη σωστή χρήση της μονάδας. παρακαλούμε διαβάστε προσεκτικά το παρόν εγχειρίδιο και φυλάξτε το για αναφορά στο μέλλον.
N1MVI-09WiFiR/ N1MVO-09 N1MVI-12WiFiR/ N1MVO-12
User’s Manual
Wall Mounted Unit
Split de perete
Manual de utilizare
Επιτοίχια Μονάδα
Εγχειρίδιο Χρήστη
DISPOSAL: Donotdisposeofthisproductasunsortedmunicipalwaste.Collectionofsuchwaste
separatelyforspecialtreatmentisnecessary.
Itisprohibitedtodisposeofthisapplianceindomestichouseholdwaste.Fordisposal,thereare severalpossibilities: A)Themunicipalityhasestablishedcollectionsystems,whereelectronicwastecan
bedisposedofatleastfreeofchargetotheuser.
B)Whenbuyinganewproduct,theretailerwilltakebacktheoldproductatleast
freeofcharge.
C)Themanufacturerwilltakebacktheoldappliancefordisposalatleastfreeof
chargetotheuser.
D)Asoldproductscontainvaluableresources,theycanbesoldtoscrapmetal
dealers. Wilddisposalofwasteinforestsandlandscapesendangersyourhealthwhenhazardous substancesleakintotheground-waterandfindtheirwayintothefoodchain.
WhenusingthisairconditionerintheEuropeancountries,pleasereadthefollowing information:
Thisappliancecanbeusedbychildrenagedfrom8yearsandaboveandpersonswith reducedphysical,sensoryormentalcapabilities,orlackofexperienceandknowledgeifthey havebeengivensupervisionorinstructionconcerninguseoftheapplianceinasafewayand understandthehazardsinvolved.Childrenshallnotplaywiththeappliance.Cleaninganduser maintenanceshallnotbemadebychildrenwithoutsupervision.
CONTENTS
SAFETYPRECAUTIONS
NAMESOFPARTS
OPERATINGINSTRUCTIONS
CAREANDMAINTENANCE
TROUBLESHOOTINGTIPS
Warning.....................................................................................................................................3
Caution......................................................................................................................................4
.
Indoorunit................................................................................................................................5
outdoorunit...............................................................................................................................5
Indicationlamp...........................................................................................................................5
Specialfunctions.......................................................................................................................6
Operatingtemperature................................................................................................................7
Manualoperation......................................................................................................................7
Airflowdirectioncontrol............................................................................................................8
Howtheairconditionerworks..................................................................................................9
Beforemaintenance.................................................................................................................10
Cleaningtheunit.......................................................................................................................10
Cleaningtheairfilterandairfresheningfilter..........................................................................10
Replacementoftheairfilterandairfresheningfilter...............................................................11
Preparationforextendednon-operation....................................................................................11
Pre-seasoninspection...............................................................................................................11
Normalfunctionoftheairconditioner.......................................................................................12
Troubleshootingguide.............................................................................................................14
SAFETYPRECAUTIONS SAFETYPRECAUTIONS
Topreventinjurytotheuserorotherpeopleandpropertydamage,thefollowinginstructions mustbefollowed.Incorrectoperationduetoignoringofinstructionsmaycauseharmordamage.
Theseriousnessisclassifiedbythefollowingindications.
Thissymbolindicatesthepossibilityofdeathorseriousinjury.
Meaningsofsymbolsusedinthismanualareasshownbelow.
WARNING
Besuretofollowtheinstructions.
Strictlyprohibited.
CAUTION
Thissymbolindicatesthepossibilityofinjuryordamagetoproperty.
Donotextendthecableandneveruse multipleplugs.Apoorelectricalconnection, poorinsulationorvoltagewhichishigher thanpermittedcancausefire. Donotexposeyourbodydirectlytothecool airforprolongedperiod. Neverpokefingers,sticksorotherobjects intheairinletandoutletvents. Neverattempttorepair,relocate,modifythe airconditioneryourself.Alwayscontactyour servicepartnerifitrequires. Neverpulltheplugoutbypullingonthe cable.Holdtheplugfirmlyandpullitoutof theplugsocket,otherwisethereisariskof damagingthecable. Donotoperateyourairconditionerinawet roomsuchasabathroomorlaundryroom.
Neveractuateanyswitcheswithawet hand.Itmaycauseanelectricshock. Neverusethedeviceforanyother purposethantheintendeduse.Never placefood,precisioninstruments,plants, animals,paint,etc.ontheunit. Donotexposeplantsoranimalsdirectly totheairflow. Nevercleantheairconditionerwithwater. Neverusecombustiblecleaningagents asthesecouldcauseafireordeformation. Neverplaceanyburningobjectscloseto thedeviceiftheycouldbedirectlyaffected bytheemittedair. Neverstepontotheoutdoordeviceand neverplaceanythingonit. Neveruseanunsteadyorrustybase. Neverinstalltheairconditionerinplaces wherecombustiblegascanbeemitted. Emmittedgasmaycollectandcausean explosion. Neverallowtheairconditionertorunfor toolongwiththedoorsorwindowsopen, orifthehumidityisveryhigh.
Removealldirtfromthepowerplugand plugitfirmly.Soiledplugscancausefire oranelectricshock. Intheeventofanyabnormalitiessuch assmellofburning,immediatelyswithch offthedeviceandpulltheplug.Contact yourservicepartner. Alwaysswitchoffthedeviceandpullthe
plugbeforeyoustarttocleanit. Usespecifiedpowercord. Contacttheauthorizedinstallerfor installationofthisunit. Contactanauthorizedservicetechnician forrepairormaintenanceofthisunit. Thisapplianceisnotintendedforuseby persons(includingchildren)withreduced physical,sensoryormentalcapabilities,or lackofexperienceandknowledge,unless theyhavebeengivensupervisionor instructionconcerninguseoftheappliance byapersonresponsiblefortheirsafety. Childrenshouldbesupervisedtoensure thattheydonotplaywiththeair conditioner.
Iftheairconditioneristobeusedin conjunctionwithotherheaters,theair shouldberefreshedperiodically,otherwise thereisariskoflackofoxygen. Alwayspulloutthepowerplugiftheunit isnotgoingtobeusedforanylengthy periodoftime.Collectionsofdustcan causefire. Alwaysswitchofftheairconditionerand pulloutthepowerplugduringastorm. Electricalpartsmaygetdamaged. Checkthatthedrainagelineiscorrectly connected.Ifnot,waterwillescape. Checkthatthecondensationwatercan runoffunhindered.Itmaycausewater damageifthecondensationwatercannot runoffproperly. Theairconditonermustbeearthedin accordancewiththelocalcodes. Forelectricalsafetypurposeswe recommendthatyouinstallanearth­leakagecircuit-breaker. Ifthepowercordisdamaged,itmustbe replacedbythemanufacturer,itsservice agentorsimilaryqualifiedpersonsinorder toavoidahazard.
WARNING
CAUTION
OPERATINGINSTRUCTIONS
8.Connecting
9.Connecting
10.Stopvalve
pipe cable
Outdoorunit
Outdoorunit
NOTE: Thedisplayontheindoorunit
youpurchasedmaylooklikeoneof thefollowing:
1.Frontpanel
2.Airinlet
3.Airfilter
4.Airoutlet
5.
6.
7.Displaypanel
Horizontalairflowgrille
Verticalairflowlouver(inside)
Indoorunit
Indoorunit
9
10
8
RUNindicationlamp
Thislampilluminateswhentheair conditionerisinoperation.
FRESHindicationlamp(optionalfunction)
ThislampilluminateswhenClean Airfeatureisactivated.
AUTOindicationlamp
Lightsupunderautooperation..
TIMERindicationlamp
LightsupduringTimeroperation.
DEFROSTindicationlamp
(Applicabletocooling&heatingmodelsonly):
whentheairconditionerstarts defrostingautomaticallyorwhenthewarm aircontrolfeatureisactivatedinheating operation.
Lightsup
Temperatureindicator
Displaysthetemperaturesettingswhenthe airconditionerisoperational. Displaysthemalfunctioncode.
()A
()B
()
C
freshdefrostruntimer
freshdefrostruntimer
autodefrostruntimer
NAMESOFPARTS
Indicationlamp
Indicationlamp
NOTE:
Allthepicturesinthismanualarefor explanationpurposesonly.
The
actualshapeshallprevail.
Theactualshape oftheindoorunityoupurchasedmaybeslight differentonfrontpanelanddisplaywindow.
Namesofparts
Specialfunctions
ThisairconditionerisequippedwithionizerorPlasmaDustCollector(Dependingonspecific configurationofthemodel).WiththeanionsgeneratedbyIonizer,theaircirculationoftheair conditionerfillstheroomwithrefreshing,naturalandhealthyair.ThePlasmaDustCollector generatesahighvoltageionizationzone,throughwhichtheairisconvertedtoplasma.Inside
theairmostofthedust,smoke,andpollenparticlesarecapturedbytheelectrostaticfilter.
CLEANAIRfunction(optional):
Verticalswingfunction(optional):
Aftertheairconditionerstartsup,userscancontroltheverticallouverswingbytheremote
controller.
SELFCLEANfunction(optional):
FunctionusedaftertheShutDownofcoolingoperationtocleantheEvaporator andkeepitasfreshforthenextoperation. Theunitwilloperateasfollowingsequence:FANONLYmodeatLowfanspeed--Heating operationwithLOWfanspeed(applicabletocooling&heatingmodlesonly)---FANONLY operation--StopOperation---Turnoff.
ThisfunctionisonlyavailableunderCOOL(AUTOCOOL,FORCEDCOOL)andDRYmode. Beforeselectthefunction,itisrecommendedtoruntheairconditionerunderCooling operationforabouthalfanhour.OncetheSelfCleanfunctionisactivated,allTIMER settingwillbecancelled. DuringSelfCleanoperation,whenpresstheSELFCLEANbuttonontheremote controlleragainwillstoptheoperationandturnofftheunitautomatically.
Note:
LouverAngleMemoryFunction(optional):
Withinthescopeofsafetyangle,itwillmemorizetheopenangleofhorizontallouver. Ifitexceeds,itwillmemorizetheboundryofsafetyangle.Inthefollowingcircumstances, itwillreturntostandardangle:1)pressingthemanualswitch,2)unplugandthenplug inthemachine.
Sowestronglysuggestthattheopenangleofthehorizontallouvershould
notbesettoosmall,incasethecondensedwaterformsanddripsfromthehorizontallouver.
RefrigerantLeakageDetection(optional):
Withthisnewtechnology,thedisplayareawillappearECandtheindicationlamps continueflashingwhentheoutdoorunitdetectsrefrigerantleakage.
,
,
DisplaysforthreesecondswhenTimerON,Fresh,Swing,Turbo orSilencefeatureisactivated. DisplaysforthreesecondswhenTimerOFFisset. DisplaysforthreesecondswhenFresh,Swing,TurboorSilence featureiscancelled. Displaysunderdefrostingoperation. Displayswhenanti-coldairfeatureis activatedunderheatingmode. Displaysduringselfcleanoperation(ifapplicable). Displaysunder8Cheatingoperation(ifapplicable).
Displaysthespecialfunctionsinthefollowingways(forsomemodelsonly):
O
, ,
,
,
,
,
,
,
,
,
,
,
, ,
OPERATINGINSTRUCTIONS
Airflowdirectioncontrol
Adjusttheairflowdirectionproperly,otherwiseit mightcausediscomfortorcauseunevenroom temperatures. Adjustthehorizontal/verticallouverusingtheremote controller.Forsomemodels,theverticallouvercan onlybeadjustedmanually.
Performthisfunctionwhiletheunitisinoperation. Usetheremotecontrollertoadjusttheairflowdirection. Thevertical/horizontallouverchanges6degreeinangle
foreachpress,orswingupanddownautomatically. PleaserefertotheREMOTECONTROLLEROPERATION MANUALfordetails.
Tosetthehorizontal/verticalairflowdirection
Forsomemodels,theverticallouvercanonlybeadjusted manually.Movethedeflectorrodmanuallytoadjusttheair flowinthedirectionyouprefer.
:Donotputyourfingersintothepanelof
blowerandsuctionside.
IMPORTANT
Thehigh-speedfaninsidemay
causedanger.
Donotoperatetheairconditionerforlongperiodswith theairflowdirectionsetdownwardincoolingor dehumidifyingmode.Otherwise,condensationmay occuronthesurfaceofthehorizontallouvercausing
moisturetodropontothefloororonfurnishings. Whentheairconditionerisstartedimmediatelyafterit wasstopped,thehorizontallouvermightnotmovefor approximately10seconds. Openangleofthehorizontallouvershouldnotbeset toosmall,asCOOLINGorHEATINGperformancemay beimpairedduetotoorestrictedairflowarea. Donotmovethehorizontallouvermanually,othe
rwise
thehorizontallouverwillbeoutofsync.Pleasecease operating,unplugpowerforafewseconds,thenrestart theairconditioner. Donotoperateunitwithhorizontallouverinclosed position.
CAUTION
,,
,,
OPERATINGINSTRUCTIONS
NOTE:ThismanualdoesnotincludeRemoteControllerOperations,seethe <<RemoteControllerInstruction>>packedwiththeunitfordetails.
Deflectorrod
Range
Range
AUTO/COOL
Suspensionbars
AUTO/COOL
()1
()2
Manualoperation
Operatingtemperature
Manualswitch
Manualswitch
Mode Temperature Roomtemperature
Outdoortemperature
1.Optimumperformancewillbeachievedwithintheseoperatingtemperatures.Ifair conditionerisusedoutsideoftheaboveconditions,certainsafetyprotectionfeatures mightcomeintooperationandcausetheunittofunctionabnormally.
2.Iftheairconditionerrunsforalongtimeincoolingmodeandthehumidityishigh(over 80%),condensedwatermaydripoutoftheunit.Pleasesetstheverticalairflowlouverto itsmaximumangle(verticallytothefloor),andsetHIGHfanmode.
Suggestion: FortheunitadoptsanElectricHeater,whentheoutsideambienttemperature
isbelow0C(32F),westronglyrecommendyoutokeepthemachinepluggedinorderto
guaranteeitrunningsmoothly.
OO
NOTE:
Coolingoperation
Heatingoperation Dryingoperation
-15505122
Forthemodelswithlow
temperaturecoolingsystem
050
32122
-1530 586
050
32122
Openandliftthefrontpaneluptoanangle untilitremainsfixedwithaclickingsound. Forsomemodels,pleaseusesuspension barstopropupthepanel.
Closethepanelfirmlytoitsoriginal position.
Onepressofthemanualcontrolswitchwill leadtotheforcedAUTOoperation.Ifpress theswitchtwicewithinfiveseconds,theunit willoperateunderforcedCOOLoperation.
Thisswitchisusedfortestingpurposes only.Youhadbetternotchooseit. Torestoretheremotecontrolleroperation, usetheremotecontrollerdirectly.
CAUTION:
1
3
2
NOTE: Theunitmustbeturnedoffbefore operatingthemanualcontrolbutton.Ifthe unitisoperational,continuepressingthe manualcontrolbuttonuntiltheunitisoff.
17C~32C (62F~90F)
OO
OO
0C~30C (32F~86F)
OO
OO
10C~32C (50F~90F)
OO
OO
Unitsareequippedwithaswitchtorunemergencyoperationmode.Itcanbeaccessedby openingthefrontpanel.Thisswitchisusedformanualoperationincasetheremotecontroller failstoworkormaintenancenecessary.
CAREANDMAINTENANCE
CareandMaintenance
OPERATINGINSTRUCTIONS
Howtheairconditionerworks
1hour
1hour
Set Temperature
Set Temperature
Cooling
Heating
SLEEPoperation
1hour
1hour
SLEEPoperation
7hourstimeroff
7hourstimeroff
AUTOoperation
SLEEPoperation
DRYINGoperation
Optimaloperation
WhenyousettheairconditionerinAUTOmode,itwill automaticallyselectcooling,heating(cooling/heating modelsonly),orfanonlyoperationdependingonset temperatureandtheroomtemperature. Theairconditionerwillcontrolroomtemperature automaticallytothetemperaturepointyouset. IfyoufeeluncomfortableintheAUTOmode,youcanset yourdesiredtemperature.
WhenyoupushSLEEPbuttononremotecontroller duringcooling,heating(cooling&heatingmodelsonly), orAUTOoperation,theairconditionerwill automaticallyincrease(cooling)ordecrease(heating)
perhourforthefirst2hours,thenhold steadilyforthenext5hours,afterthatitwillswitchoff. Thismodesavesyouenergyandbringsyoucomfort atnight.
Toachieveoptimalperformance,pleasenotethe following: Adjusttheairflowdirectioncorrectlysothatitisnot torwardspeople. Adjustthetemperaturetoachievethehighestcomfort level.Donotadjusttheunittoexcessivetemperature levels. ClosedoorsandwindowsonCOOLorHEATmodes, orperformancemaybereduced. UseTIMERONbuttonontheremotecontrollerto selectatimeyouwanttostartyourairconditioner. Donotputanyobjectnearairinletorairoutlet,asthe efficiencyoftheairconditionermaybereducedand theairconditionermaystoprunning. Cleantheairfilterperiodically,otherwisecoolingor heatingperformancemaybereduced. Donotoperateunitwithhorizontallouvreinclosed position.
Thefanspeedwillbeautomaticallycontrolledunder dryoperation. Duringthedryoperation,iftheroomtemperatureis lowerthan10C(50F),thecompressorstopsoperation andrestartsuntiltheroomtemperatureisabove 12C(54F).
OO
OO
FilterHandle
Beforemainatenance
Aclothdampenedwithcoldwatermaybeused ontheindoorunitifitisverydirty.Thenwipeit withadrycloth. Donotuseachemicallytreatedclothordusterto cleantheunit. Donotusebenzine,thinner,polishingpowder,or similarsolventsforcleaning.Thesemaycause
theplasticsurfacetocrackordeform. Neverusewaterhotterthan40C/104Ftoclean thefrontpanel,itcouldcausedeformationof discoloration.
CAUTIONS
Turnthesystemoffbeforecleaning.Toclean,wipewith asoft,drycloth.Donotusebleachorabrasives.
NOTE:Powersupplymustbedisconnectdbefore cleaningtheindoorunit.
Acloggedairfilterreducesthecoolingefficiencyof thisunit.Pleasecleanthefilteronceevery2weeks.
1.Lifttheindoorunitpaneluptoanangleuntilit stopswithaclickingsound.Forsomemodels, pleaseusesuspensionbarstopropupthepanel.
2.Takeholdofthehandleoftheairfilterandliftit
upslightlytotakeitoutfromthefilterholder, thenpullitdownwards.
3.RemovetheAIRFILTERfromtheindoorunit.
CleantheAIRFILTERoncetwoweeks. CleantheAIRFILTERwithavacuumcleaner orwater,thendryitupincoolplace.
Cleaningtheairfilterandairfresheningfilter
CARE AND MAINTENANCE TROUBLE SHOOTING TIPS
4. Remove the Air Freshening Filters from its supporting frame (The solution to disassemble may differ from each other for different filters. Refer to and ). Clean the air freshening filter at least once a month, and replace it every 4-5 months. Clean it with vacuum cleaner, then dry it in cool place. For the models with plasma, do not touch the plasma within 10 minutes after you open the panel.
5. Install the air freshening filter back into position .
6. Insert the upper portion of ai
r filter back into the unit, taking care that the left and right edges line up correctly and place filter into position.
1 2
Preparation for extended non-operation
Pre-season inspection
If you plan to idle the u nit for a long t ime, perform the following:
(1) Clean the indoor unit and filters.
Operate the fan for about half a day to dry the
inside of the unit.
Stop the air conditioner and disconnect power.
(4)
The outdoor unit requires periodic maintenance
and cleaning. Do not attempt to do this yourself. Contact your dealer or service provider.
(2)
(3)
Remove the batterie s from the remote controller.
Check that the wiring is not b roken off or disconnected. Clean the in
door unit and filters. Check that the air filter is installed. Check if the air outlet or inlet is blocked after the air conditioner has not been used for a long time.
Do not touch the metal parts of th e unit when removing the filter. Injuries can occur when handling sharp metal edges. Do not use water to clean inside the a ir conditioner. Exposure to water can destroy the insulation, leading to possible electric shock. When cleaning the unit, first m ake sure that the power and circuit breaker are turn ed off. Do not wash air filter with hot wat er at more than 40 C . Shake off moisture completely and dry it in the shade. Do not expose it directly to th
e sun,
it may shrink.
O
/104 F
O
Cau tion
Replacement of air filter and air freshening filter
1. Remove the air filter.
2. Remove the air freshening filter.
3. Install a new air freshening filter.
4. Reinstall the air filter and securely close the front panel.
The following events may occur during normal operation.
1.
The compressor can't restart for 3-4 minutes after it stops.
The unit is designed not to blow cold air on HEAT mode, when the indoor heat exchanger is in one of the following three situations and the set tem
perature has not been reached. A) When heating has just started. B) Defrosting. C) Low temperature heating. The indoor or outdoor fan stop running when defrosting (Cooling and heating models only).
Frost may be generated on the outdoor unit during heat cycle when outdoor temperature is low and humidity is high resulting in lower heating efficiency of the air conditioner. During this condition air conditioner will stop heating operation and start defrosting automaticall
y.
The time to defrost may vary from 4 to 10 minutes according to the outdoor temperature and
the amount of frost built up on the outdoor unit.
2. A white mist may generate due to a large temperature difference between air inlet and air outlet on COOL mode in an indoor environment that has a high relative humidity. A white mist may generate due to moisture generated from defrosting process when the air conditioner restarts in HEAT mode operation after defrosting.
3. You may hear a l
ow hissing sound when the compressor is running or has just stopped running. It is the sound of the refrigerant flowing or coming to a stop. You can also hear a low "squeak" sound when the compressor is running or has just stopped running. This is caused by heat expansion and cold contraction of the plastic parts in the unit when the temperature is changing. A noise may be heard due to louver restoring to its original position when power is turned on.
4. This is a normal condition when t
he air conditioner has not been used for a long time or during first
use of the unit.
5. This is caused by the indoor unit g iving off smells permeated from building material, from furniture, or smoke.
Protection of the air conditioner.
Compressor protection
Anti-cold air (Cooling and heating models only)
Defrosting (Cooling and heating models only)
A white mist coming out from the indoor unit
Low noise of the air conditioner
Dust is blown out from the indoor unit.
A peculiar sm
ell comes out from the indoor unit.
6.
When indoor temperature reaches the temperature setting on air conditioner, the compressor will stop automatically,and the air conditioner t urns to FAN only mode. The compressor will start again when the indoor temperature rises on COOL mode or falls on HEAT mode (For cooling and heating models only) to the set point.
The air conditioner turns to FAN only mode from COOL or HEAT (For cooling and
heating models only) mode.
Normal function of the air conditioner
TROUBLESHOOTINGTIPS
Malfunctions
Unitdoesnot start
Unitnotcooling orheating (Cooling/heating
modelsonly) roomverywell whileairflowing outfromtheair condtioneri
Cause
Powercut Unitmayhavebecome
Unplugged.
Fusemayhaveblown.
BatteryinRemotecontrollermay havebeenexhausted.
Thetimeyouhavesetwithtimer isincorrect.
Waitforpowertoberestored. Checkthatplugissecurelyinwall
receptacle. Replacethefuse.
Replacethebattery.
Waitorcanceltimersetting.
Settemperaturecorrectly.For detailedmethodpleasereferto ""Usingremotecontrolsection.
Cleantheairfilter. Closethedoorsorwindows.
Clearobstructionsawayfirst,then restarttheunit.
Wait.
Inappropriatetemperature setting.
Airfilterisblocked.
DoorsorWindowsareopen.
Airinletoroutletofindooror
outdoorunithasbeenblocked. Compressor3minutes
protectionhasbeenactivated.
Ifthetroublehasnotbeencorrected,pleasecontactalocaldealerorthenearestcustomer servicecenter.Besuretoinformthemofthedetailedmalfunctionsandunitmodelnumber.
Notes:Donotattempttorepairtheunityourself.
Alwaysconsultanauthorizedserviceprovider.
Whatshouldbedone?
TROUBLESHOOTINGTIPS
Troubleshootingguide
8.Drippingwatermaygenerateonthesurfaceoftheindoorunitwhencoolinginahigh relativelyhumidity(relativehumidityhigherthan80%).Adjustthehorizontallouverto themaximumairoutletpositionandselectHIGHfanspeed.
9. Theairconditionerdrawsinheatfromtheoutdoorunitandreleasesitviatheindoorunit duringheatingoperation.Whentheoutdoortemperaturefalls,heatdrawninbytheair conditionerdecreasesaccordingly.Atthesametime,heatloadingoftheairconditioner increasesduetolargerdifferencebetweenindoorandoutdoortemperature.Ifa comfortabletemperaturecan'tbeachievedbytheairconditioner,wesuggestyouusea supplementaryheatingdevice.
10. Powerfailureduringoperationwillstoptheunitcompletely. FortheunitwithoutAuto-restartfeature,whenthepowerrestores,theOPERATIONindicator ontheindoorunitstartsflashing.Torestarttheoperation,pushtheON/OFFbuttononthe
remotecontroller.FortheunitwithAuto-restartfeature,whenthepowerrestores,theunit restartsautomaticallywithalltheprevioussettingspreservedbythememoryfunction.
Heatingmode(Forcoolingandheatingmodelsonly)
Auto-restartfunction
7. Theairconditionerrunsfunctionafterturningofftheunit.
WhenturningofftheunitunderCOOL(AUTOCOOL,FORCEDCOOL)andDRYmode,theair conditionerwillrunfunctionfor7-10minutes,
thenstoptheoperationandturn
offtheunitautomatically.
Anti-mildew
Anti-mildew
ifturnsoffonHEATmode,theunitwill
continueoperatingforabout30secondsatLOWfanspeed,
UnderAnti-mildewoperation,donotrestarttheairconditioneruntilthe
unitiscompletelyoff.
Fuseblowsfrequentlyorcircuitbreakertrips frequently.
Otherobjectsorwaterfallintotheairconditioner. Terribleodorsaresmelledorabnormalsounds
areheard.
Trouble
OPERATION(RUN)indicatororother indicatorscontinueflashing.
Ifoneofthefollowingcodeappearsonthe
displayarea:E0,E1,E2,E3.....orP0,P1,P2,
P3....,orF1,F2,F3.......
Theunitmaystopoperationor continuetoruninasafetycondition (dependingonmodels).Waitingfor about10minutes,thefaultmaybe recoveredautomatically,ifnot, disconnectthepowerandthen connectitinagain.Iftheproblem stillexists,disconnectthepowerand contactthenearestcustomerservice center.
Stoptheairconditionerimmediately, disconnectthepowerandcontactthe nearestcustomerservicecenter.
After240hoursofoperation,theindoordisplaywindowwilldisplayandflashCL, thisfeatureisaremindertocleantheAirFilterformoreefficientoperation.After15 seconds,thesystemwillrevertbacktothepreviousdisplayagain.WhentheCL indicatorappearsandflashes,pleasepresstheLEDbuttononremotecontroller for4timesorpresstheManualcontrolbuttonfor3ormoretimestocleartheregistered hours,otherwisetheCLindicatorwilldisplayandflashagainforanother15secondsat thenexttimeofstartingtheunit.
11.Cleaningfilterremindingfunction(Optional)
,
,
,
,
,
,
After2880hoursofoperation,theindoordisplaywindowwilldisplayandflashnF, thisfeatureisaremindertoreplacetheAirFilterformoreefficientoperation.After15 seconds,thesystemwillrevertbacktothepreviousdisplayagain.WhenthenF indicatorappearsandflashes,pleasepresstheLEDbuttononremotecontrollerfor4 timesorpresstheManualcontrolbuttonfor3ormoretimestocleartheregisteredhours, otherwisethenFindicatorwilldisplayandflashagainforanother15secondsatthe nexttimeofstartingtheunit.
12.Replacingfilterremindingfunction(Optional)
,
,
,
,
,
,