INVENTOR L2VO-09, L2VO-12, S2VO-09, S2VO-12 Owner's Manual

L2VO-09 L2VO-12
Owner’s Manual
66129918211
English
Thank you for choosing INVENTOR air conditioning system. For correct use of this unit, please read this manual carefully and keep it for future reference.
Content
Operation Notices
Precautions..........................................................................................................1
Parts Name..........................................................................................................6
Installation Notice
Installation dimension diagram .............................................................................7
Tools for installation ..............................................................................................8
Selection of installation location
Requirements for electric connection ...................................................................9
Installation
Installation of outdoor unit ..................................................................................10
Vacuum pumping ...............................................................................................13
Leakage detection ..............................................................................................13
Check after installation .......................................................................................14
Test and operation
Test operation ....................................................................................................14
Attachment
Pipe expanding method ...................................................................................... 71
...........................................................................8
epip noitcennoc fo noitarugifnoC ....................................................................... 51
This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm to the environment or human health from un­controlled waste disposal, recycle it responsibly to promote the sustainable reuse of mate­rial resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for envi­ronmental safe recycling.
R410A(R32/125: 50/50): 2087.5
Precautions
WARNING
Operation and Maintenance
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be m ade by
children without supervision. Do not connect air conditioner to multi-purpose socket.
Otherwise, it may cause fire hazard. Do disconnect power supply when cleaning air
conditioner. Otherwise, it may cause electric shock. If the supply cord is damaged, it must be replaced by
the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
Do not wash the air conditioner with water to avoid electric shock. Do not spray water on indoor unit. It may cause electric shock or malfunction.
After removing the filter, do not touch fins to avoid injury. Do not use fire or hair dryer to dry the filter to avoid
deformation or fire hazard.
1
.
Precautions
WARNING
Maintenance must be performed by qualified professionals. Otherwise, it may cause personal injury
or damage. Do not repair air conditioner by yourself. It may cause
electric shock or damage. Please contact dealer when you need to repair air conditioner.
Do not extend fingers or objects into air inlet or air outlet. It may cause personal injury or damage.
Do not block air outlet or air inlet. It may cause malfunction.
Do not spill water on the remote controller, otherwise the remote controller may be broken. When below phenomenon occurs, please turn off air conditioner and disconnect power immediately, and then contact the dealer or qualified professionals for service.
Power cord is overheating or damaged.
There’s abnormal sound during operation.
Circuit break trips off frequently.
Air conditioner gives off burning smell.
Indoor unit is leaking.
If the air conditioner operates under abnormal conditions, it may cause malfunction, electric shock or fire hazard.
When turning on or turning off the unit by emergency operation switch, please press this switch with an insulating object other than metal.
Do not step on top panel of outdoor unit, or put heavy objects. It may cause damage or personal injury.
2
Precautions
WARNING
Attachment
Installation must be performed by qualified professionals. Otherwise, it may cause personal injury or damage.
Must follow the electric safety regulations when installing the unit.
According to the local safety regulations, use qualified power supply circuit and circuit break.
Do install the circuit break. If not, it may cause malfunction. An all-pole disconnection switch having a contact separation
of at least 3mm in all poles should be connected in fixed wiring.
Including an circuit break with suitable capacity, please note magnet buckle
the circuit-short and
the following table. Air switch should be included
and heating buckle function, it can protect
overload.
Air Conditioner should be properly grounded. Incorrect grounding may cause electric shock.
Don't use unqualified power cord. Make sure the power supply matches with the
requirement of air conditioner. Unstable power supply or incorrect wiring or malfunction. Please install proper power supply cables before using the air conditioner.
Properly connect the live wire, neutral wire and grounding wire of power socket.
Be sure to cut off the power supply before proceeding any work related to electricity and safety.
3
Precautions
WARNING
Do not put through the power before finishing installation. If the supply cord is damaged, it must be replaced by
the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
The temperature of refrigerant circuit will be high, please keep the interconnection cable away from the copper tube.
The appliance shall be installed in accordance with national wiring regulations.
Installation must be performed in accordance with the requirement of NEC and CEC by authorized personnel only.
The air conditioner is the first class electric appliance. It must be properly grounding with specialized grounding device by a professional. Please make sure it is always grounded effectively, otherwise it may cause electric shock.
The yellow-green wire in air conditioner is grounding wire, which can't be used for other purposes.
The grounding resistance should comply with national electric safety regulations.
The appliance must be positioned so that the plug is accessible.
All wires of indoor unit and outdoor unit should be connected by a professional.
If the length of power connection wire is insufficient, please contact the supplier for a new one. Avoid extending the wire by yourself.
4
Precautions
WARNING
For the air conditioner with plug, the plug should be reachable after finishing installation.
For the air conditioner without plug, an circuit break must be installed in the line.
If you need to relocate the air conditioner to another place, only the qualified person can perform the work. Otherwise, it may cause personal injury or damage.
Select a location which is out of reach for children and far away from animals or plants.If it is unavoidable, please add the fence for safety purpose.
The indoor unit should be installed close to the wall. Instructions for installation and use of this product are
provided by the manufacturer.
Working temperature range
Indoor side DB/WB(℃) Outdoor side DB/WB(℃)
Maximum cooling 32/23 43/26
Maximum heating 27/- 24/18
NOTICE:
The operating temperature range (outdoor temperature) for cooling only unit is
-15℃~ 43℃; for heat pump unit is -15℃~ 43℃.
5
Parts name
Indoor Unit Outdoor Unit
air inlet
Connection wire
air outlet
NOTICE:
Actual product may be different from above graphics, please refer to actual products.
6
Installation dimension diagram
At least 30cm
Space to the wall
At least 200cm
Space to the obstruction
Space to the
obstruction
Space to the obstruction
At least 50cm
At least
30cm
7
At least 50cm Space to the
obstruction
Drainage pipe
Tools for installation
1 Level meter 2 Screw driver 3 Impact drill 4 Drill head 5 Pipe expander 6 Torque wrench
7 Open-end wrench 8 Pipe cutter 9 Leakage detector 10 Vacuum pump 11 Pressure meter 12 Universal meter
13 Inner hexagon spanner 14 Measuring tape
Note:
● Please contact the local agent for installation.
Selection of installation location
Basic requirement
Installing the unit in the following pla-ces maycause malfunction. If it is un­avoidable, please consult the localdealer:
1.The place with strong heat sources,vapors,flammable or explosive gas,or
volatile objects spread in the air.
2.The place with high-frequency devices (such as welding machine, medical equipment).
3.The place near coast area.
4.
The place with oil or fumes in the air.
5.The place with sulfureted gas.
6.Other places with special circumstances.
7.Do not use the unit in the immediate surroundings of a laundry a bath a shower or a swimming pool.
Outdoor unit
will not affect neighborhood.
2. The location should be well ventilated and dry, in which the outdoor unit
won't be exposed directly to sunlight or strong wind.
3. The location should be able to withstand the weight of outdoor unit.
4. Make sure that the installation follows the requirement of installation dimension diagram.
5. Select a location which is out of reach for children and far away from animals or plants.If it is unavoidable, please add the fence for safety purpose.
8
Requirements for electric connection
Safety precaution
1. Must follow the electric safety regulations when installing the unit. circuit break.
3. Make sure the power supply matches with the requirement of air conditioner. Unstable power supply or incorrect wiring or malfunction. Please install proper power supply cables before using the air conditioner.
4. Properly connect the live wire, neutral wire and grounding wire of power socket.
5. Be sure to cut off the power supply before proceeding any work related to electricity and safety.
7. If the supply cord is damaged, it must be replaced by the manufacturer, its
8. The temperature of refrigerant circuit will be high, please keep the interconnec­ tion cable away from the copper tube.
9. The appliance shall be installed in accordance with national wiring regulations.
10.Installation must be performed in accordance with the requirement of NEC and CEC by authorized personnel only
Grounding requirement
grounding with specialized grounding device by a professional. Please make sure it is always grounded effectively, otherwise it may cause electric shock.
2. The yellow-green wire in air conditioner is grounding wire, which can't be used for other purposes.
3. The grounding resistance should comply with national electric safety regulations.
4. The appliance must be positioned so that the plug is accessible.
5. An all-pole disconnection switch having a contact separation of at least 3mm in
6. Including an circuit break with suitable capacity, please note the following table. Air switch should be included magnet buckle and heating buckle function, it can protect the circuit-short and overload. (Caution: please do not use the fuse only for protect the circuit)
Air-conditioner
09K 10A 12K 10A
Circuit break capacity
9
Installation of outdoor unit
foot holes
(select it according to the actual installation situation)
1. Select installation location according to the house structure.
2. Fix the support of outdoor unit on the selected location with expansion screws.
Note:
installing the outdoor unit.
Make sure the support can withstand at least
four times of the unit weight.
The outdoor unit should be installed at least joint.
● For the unit with cooling capacity of 2300W
~5000W, 6 expansion screws are needed;
for the unit with cooling capacity of 6000W
~8000W, 8 expansion screws are needed;
for the unit with cooling capacity of 10000W
~16000W, 10 expansion screws are needed.
Step two: install drain joint
gni taeh dna gni looc rof ylnO(
unit)
1. Connect the outdoor drain joint into the hole on the chassis, as shown in the picture below.
2. Connect the drain hose into the drain vent.
at least 3cm above the floor
1. Place the outdoor unit on the support.
2. Fix the foot holes of outdoor unit with bolts.
drain vent Drain hose
chassis
outdoor drain joint
foot holes
10
Installation of outdoor unit
pipe joint
Step four: connect indoor and outdoor pipes
1. Remove the screw on the right han­ dle of outdoor unit and then remove
3. Pretightening the union nut with hand.
the handle.
screw
union nut
handle
2. Remove the screw cap of valve and aim the pipe joint at the bellmouth of pipe.
liquid pipe
liquid valve
gas pipe
gas valve
4. Tighten the union nut with torque wrench by referring to the sheet below.
Hex nut diameter
Φ 6
Φ 9.52
Φ 12 Φ 16 Φ 19
Tightening torque
(N.m)
15~20
30~40
45~55 60~65 70~75
1. Remove the wire clip; connect the power connection wire and signal control wire (only for Heat pump type) to the wiring terminal according to the color;
09 12K Cool only type and Heat pump type
blue
(for some model
2 3N(1)
LN
yellow-
(
green
brown(black)
blue(
yellow-
black brown
green
Indoor unit connection
white
POWER
green
)
)
11
L N
Installation of outdoor unit
2. Fix the power connection wire and signal control wire with wire clip (only for cooling and heating unit).
Note:
● Never cut the power connection wire to prolong or shorten the distance.
Step six: neaten the pipes
1. The pipes should be placed along the wall, bent reasonably and hidden possibly. Min. semidiameter of bending the pipe is 10cm.
2. If the outdoor unit is higher than the wall hole, you must set a U-shaped curve in the pipe before pipe goes into the room, in order to prevent rain from getting into the room.
U-shaped curve
drain hose
wall
12
Vacuum pumping
Use vacuum pump
1. Remove the valve caps on the liquid valve and gas valve and the nut of refri­ gerant charging vent.
2. Connect the charging hose
of piezometer to the refri-
gerant charging vent of gas valve and then connect the other charging hose to the vacuum pump.
3. Open the piezometer com-
pletely and operate for 10-15min to check if the
pressure of piezometer re-
mains in -0.1MPa.
4. Close the vacuum pump and maintain this status for 1-2min to check if the pres-
sure of piezometer remains
in -0.1MPa. If the pressure decreases, there may be leakage.
5. Remove the piezometer, open the valve core of liquid valve and gas valve
completely with inner hexagon spanner.
6. Tighten the screw caps of valves and refrigerant charging vent.
7. Reinstall the handle.
liquid valve
gas valve
refrigerant charging vent
nut of refrigerant charging vent
piezometer
valve cap
vacuum pump
inner hexagon spanner
close
open
Lo Hi
Leakage detection
1. With leakage detector: Check if there is leakage with leakage detector.
2. With soap water: If leakage detector is not available, please use soap water for leakage detection.
Apply soap water at the suspected position and keep the soap water for more
than 3min. If there are air bubbles coming out of this position, there's a leakage.
13
Check after installation
● Check according to the following requirement after nishing installation.
Items to be checked Possible malfunction
Has the unit been installed rmly? The unit may drop, shake or emit noise. Have you done the refrigerant leakage
test?
Is heat insulation of pipeline sufcient?
Is water drained well?
It may cause insufcient cooling
(heating) capacity. It may cause condensation and water
dripping. It may cause condensation and water
dripping.
Is the voltage of power supply accord­ing to the voltage marked on the nameplate?
Is electric wiring and pipeline installed correctly?
Is the unit grounded securely? It may cause electric leakage. Does the power cord follow the speci-
cation?
Is there any obstruction in the air inlet and outlet?
The dust and sundries caused during installation are removed?
The gas valve and liquid valve of connection pipe are open completely?
It may cause malfunction or damaging the parts.
It may cause malfunction or damaging the parts.
It may cause malfunction or damaging the parts.
It may cause insufcient cooling
(heating) capacity. It may cause malfunction or damaging
the parts.
It may cause insufcient cooling
(heating) capacity.
Test operation
1. Preparation of test operation
● The client approves the air conditioner.
● Specify the important notes for air conditioner to the client.
2. Method of test operation
● Put through the power, press ON/OFF button on the remote controller to start
operation.
● Press MODE button to select AUTO, COOL, DRY, FAN and HEAT to check
whether the operation is normal or not.
● If the ambient temperature is lower than 16
start cooling.
14
, the air conditioner can’t
Configuration of connection pipe
1. Standard length of connection pipe
● 5m, 7.5m, 8m.
2. Min. length of connection pipe is 3m.
3. Max. length of connection pipe and max. high difference.
Cooling
capacity
5000Btu/h
(1465W)
7000Btu/h
(2051W)
9000Btu/h
(2637W)
12000Btu/h
(3516W)
18000Btu/h
(5274W)
4. The additional refrigerant oil and refrigerant charging required after prolonging connection pipe
● After the length of connection pipe is prolonged for 10m at the basis of
standard length, you should add 5ml of refrigerant oil for each additional 5m
of connection pipe.
The calculation method of additional refrigerant charging amount (on the basis of liquid pipe):
Additional refrigerant charging amount = prolonged length of liquid pipe ×
additional refrigerant charging amount per meter
Basing on the length of standard pipe, add refrigerant according to the
requirement as shown in the table. The additional refrigerant charging amount per meter is different according to the diameter of liquid pipe. See the
following sheet.
Max length of connec­tion pipe
15 255 10
15 305 10
15 305 20
20 3010 20
25 3010 20
Max height difference
Cooling
capacity
24000Btu/h
(7032W)
28000Btu/h
(8204W)
36000Btu/h
(10548W)
42000Btu/h
(12306W)
48000Btu/h
(14064W)
Max length of connec­tion pipe
Max height difference
15
Conguration of connection pipe
Additional refrigerant charging amount for R22, R407C, R410A and R134a
Diameter of connection pipe
Liquid pipe(mm) Gas pipe(mm)
Φ6
Φ6 or Φ9.52
Φ12
Φ16
Φ19
Φ22.2
Φ9.52 or Φ12
Φ16 or Φ19
Φ19 or Φ22.2
Φ25.4 or Φ31.8
_ _
Outdoor unit throttle
Cooling only(g/m) Cooling and heating(g/m)
15 15
30
60
250 250
20 50
120
120
350350
16
Pipe expanding method
pipe
pipe
smooth surface
Note:
Improper pipe expanding is the main cause of refrigerant leakage. Please expand the pipe according to the following steps:
A: Cut the pipe
● Conrm the pipe length according to
the distance of indoor unit and outdoor unit.
● Cut the required pipe with pipe cutter.
pipe cutter
E: Expand the port
● Expand the port with expander.
hard
expander
mold
pipe
leaning uneven burr
B: Remove the burrs
● Remove the burrs with shaper and
prevent the burrs from getting into the pipe.
shaper
downwards
C: Put on suitable insulating pipe D: Put on the union nut
● Remove the union nut on the indoor
connection pipe and outdoor valve; install the union nut on the pipe.
union pipe
Note:
● "A" is different according to the
diameter, please refer to the sheet below:
Outer diameter
(mm)
Φ6-6.35(1/4")
Φ9.52(3/8")
Φ12-12.7(1/2")
Φ15.8-16(5/8")
A(mm)
Max Min
1.3 0.7
1.6 1.0
1.8 1.0
2.4 2.2
F: Inspection
● Check the quality of expanding port.
If there is any blemish, expand the port again according to the steps above.
improper expanding
pipe
the length is equal
17
leaning
damaged
surface
crack uneven
thickness