INVENTOR L2VI-18, L2VI-24 Owner's Manual

Owner’s Manual
Thank you for choosing INVENTOR air conditioning system. For correct use of this unit, please read this manual carefully and keep it for future reference.
L2VI-18 L2VI-24
English
66129918209
This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm to the environment or human health from un­controlled waste disposal, recycle it responsibly to promote the sustainable reuse of mate­rial resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for envi­ronmental safe recycling.
R410A(R32/125: 50/50): 2087.5
Content
Operation Notices
Precautions............................................................................................................1
Parts Name............................................................................................................6
ScreenOperation Guide
Buttons on remote controller
.................................................................................
8
8
Introduction for buttons on remote controller .........................................................9
Introduction for special function
......................................................12
Operation guide...................................................................................................13
Replacement of batteries in remote controller .....................................................14
Emergency operation ..........................................................................................
15
Maintenance
Clean and Maintenance.......................................................................................
15
Malfunction
Malfunction analysis ............................................................................................
18
Installation Notice
Installation dimension diagram............................................................................
22
Tools for installation .............................................................................................
23
Selection of installation location ..........................................................................
23
Requirements for electric connection ..................................................................
24
Installation
Installation of indoor unit......................................................................................
25
Check after installation ........................................................................................
30
Test and operation
Test operation ......................................................................................................
30
Attachment
.........................................................................
31
Pipe expanding method
Configuration of connection pipe
.......................................................................................
33
Introduction for icons on display screen ................................................................
................
1
Precautions
Do not connect air conditioner to multi-purpose socket.
This appliance can be used by children aged from 8
Operation and Maintenance
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
Do not spray water on indoor unit. It may cause electric shock or malfunction.
Otherwise, it may cause fire hazard.
Children shall not play with the appliance. Cleaning and user maintenance shall not be made by
children without supervision.
years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
Do not wash the air conditioner with water to avoid electric shock.
After removing the filter, do not touch fins to avoid injury. Do not use fire or hair dryer to dry the filter to avoid
deformation or fire hazard.
Do disconnect power supply when cleaning air conditioner. Otherwise, it may cause electric shock.
WARNING
Do not block air outlet or air inlet. It may cause malfunction.
remote controller may be broken.
Power cord is overheating or damaged.
There’s abnormal sound during operation.
Circuit break trips off frequently.
Air conditioner gives off burning smell.
Indoor unit is leaking.
contact the dealer or qualified professionals for service.
When turning on or turning off the unit by emergency operation switch, please press this switch with an insulating object other than metal.
outlet. It may cause personal injury or damage.
2
Precautions
conditioner and disconnect power immediately, and then
If the air conditioner operates under abnormal conditions, it may cause malfunction, electric shock or fire hazard.
Do not spill water on the remote controller, otherwise the
electric shock or damage. Please contact dealer when you need to repair air conditioner.
Do not repair air conditioner by yourself. It may cause
objects. It may cause damage or personal injury.
Do not step on top panel of outdoor unit, or put heavy
When below phenomenon occurs, please turn off air
Do not extend fingers or objects into air inlet or air
Maintenance must be performed by qualified professionals. Otherwise, it may cause personal injury
or damage.
WARNING
Do install the circuit break. If not, it may cause malfunction.
of at least 3mm in all poles should be connected in fixed wiring.
magnet buckle
and heating buckle function, it can protect
the circuit-short and
overload.
power supply circuit and circuit break.
3
Precautions
note
the following table. Air switch should be included
Make sure the power supply matches with the requirement of air conditioner. Unstable power supply or incorrect wiring or malfunction. Please install proper power supply cables before using the air conditioner.
An all-pole disconnection switch having a contact separation
Must follow the electric safety regulations when installing the unit.
grounding wire of power socket.
Properly connect the live wire, neutral wire and
any work related to electricity and safety.
Be sure to cut off the power supply before proceeding
Including an circuit break with suitable capacity, please
Air Conditioner should be properly grounded. Incorrect
Don't use unqualified power cord.
grounding may cause electric shock.
According to the local safety regulations, use qualified
Installation must be performed by qualified professionals. Otherwise, it may cause personal injury or damage.
Attachment
WARNING
Installation must be performed in accordance with the
persons in order to avoid a hazard.
must be properly grounding with specialized grounding device by a professional. Please make sure it is always grounded effectively, otherwise it may cause electric shock.
The appliance must be positioned so that the plug is accessible.
If the length of power connection wire is insufficient, please contact the supplier for a new one. Avoid extending the wire by yourself.
All wires of indoor unit and outdoor unit should be connected by a professional.
national wiring regulations.
requirement of NEC and CEC by authorized personnel only
4
Precautions
wire, which can't be used for other purposes.
The grounding resistance should comply with national electric safety regulations.
The air conditioner is the first class electric appliance. It
keep the interconnection cable away from the copper tube.
The temperature of refrigerant circuit will be high, please
the manufacturer, its service agent or similarly qualified
If the supply cord is damaged, it must be replaced by
The yellow-green wire in air conditioner is grounding
The appliance shall be installed in accordance with
Do not put through the power before finishing installation.
WARNING
The indoor unit should be installed close to the wall
reachable after finishing installation.
far away from animals or plants. If it is unavoidable, please add the fence for safety purpose.
5
Precautions
place, only the qualified person can perform the work. Otherwise, it may cause personal injury or damage.
If you need to relocate the air conditioner to another
must be installed in the line.
For the air conditioner without plug, an circuit break
Select a location which is out of reach for children and
For the air conditioner with plug, the plug should be
Working temperature range
Indoor side DB/WB(°C) Outdoor side DB/WB(°C)
Maximum cooling 32/23 43/26
Maximum heating 27/- 24/18
The operating temperature range (outdoor temperature) for cooling is -15~43; Heating temperature range for the model without electric heating belt for chassis is -15~24
Heating temperature range for the model with electric heating belt
for chassis is -20~24 .
NOTICE:
WARNING
6
(Display content or position may be different from above graphics, please refer to actual products)
Parts Name
Indoor Unit
remote control
air inlet panel
aux.button
horizontal louver air outlet
heating indicator
temp. indicator
cooling indicator
power indicator
receiver window
drying indicator
display
NOTICE:
Actual product may be different from above graphics, please refer to actual products.
Parts Name
Display content or position may be different from above graphics, please refer to actual products.
Display
W R G
temp. indicator
display
receiver window
W R O
temp. indicator
display
receiver window
heating indicator
temp. indicator
cooling indicator
power indicator
receiver window
drying indicator
display
For some model:
For some model:
For some model:
For some model:
heating indicator
temp. indicator
cooling indicator
power indicator
receiver window
drying indicator
display
G
W
R
Power LED color indicator: Green-status-ON. Red -status-OFF.
Mode LED color indicator: White-W-Cool Mode-
Red-R-Heat Mode-
Green-G-Dry Mode-
O
W
R
Power LED color indicator: Green-status-ON. Red -status-OFF.
Mode LED color indicator: White-W-Cool Mode-
Red-R-Heat Mode­Orange-O-Dry Mode-
(only for heating model)
(only for heating model)
7
8
Buttons on remote controller
Introduction for icons on display screen
1 2 3
4 5 6 7 8
9 10 11 12
ON/OFF button MODE button
- button + button FAN button
TIMER ON button X-FAN button
TEMP button TIMER OFF button
TURBO button
13
SLEEP button
14
LIGHT button
CLOCK button
button
Turbo mode
Send signal
Set temperature
Set time TIMER ON / TIMER OFF
Child lock
Up & down swing
Set fan speed
Light
Temp. display type
:Set temp.
:Outdoor ambient temp.
:Indoor ambient temp.
Sleep mode
Clock
Heat mode
Fan mode
Dry mode
Cool mode
Auto mode
Operation mode
1 3
5 7 9
12
2 4 6
8
11
10
14
13
X-fan mode
9
Introduction for buttons on remote controller
Note:
After putting through the power, the air conditioner will give out a sound. Operation indictor " " is ON (red indicator). After that, you can operate the air conditioner by using remote controller.
Under on status, pressing the button on the remote controller, the signal icon " " on the display of remote controller will blink once and the air conditioner will give out a “de” sound, which means the signal has been sent to the air conditioner.
● Under off status, set temperature and clock icon will be displayed on the display of remote controller (If timer on, timer off and light functions are set, the corre­ sponding icons will be displayed on the display of remote controller at the same
time); Under on status, the display will show the corresponding set function icons.
ON/OFF button
1
Press this button, the unit will be turned on, press it once more, the unit will be turned off. When turning on or turning off the unit, the Timer, Sleep function will be canceled, but the presetting time is still remained.
MODE button
2
Press this button, Auto, Cool, Dry, Fan, Heat mode can be selected circularly. Auto mode
- button
3
Presetting temperature can be decreased. Press this button, the temperature can be set up,
+ button
4
For presetting temperature increasing. Press this button, can set up the temperature, when unit is on. Continuously press and hold this button for more than 2 seconds, the corresponding contents will be changed rapidly, until unpress the button then send the information, ℃(℉) is displlaying all along. In Auto mode, the temperature can not be set up, but operate this button can send the signal. Centigrade setting range: 16-30; Fahrenheit scale setting range 61-86.
continuously press this button and hold for two seconds, the relative contents can quickly change, until unhold this button and send the order that the
℃(℉
) signal will be displayed all the time. The temperature adjustment is unavailable under the Auto mode, but the order can be sent by if pressing this button.
is default while power on. Under Auto mode, the temperature will not be displayed; Under Heat mode, the initial value is 28
(82℉); Under other modes, the initial value is
25
(77℉).
AUTO COOL DRY FAN HEAT
(Only for cooling and heating unit. As for cooling only unit, it won’t have any action when it receives the signal of heating operation.)
10
Introduction for buttons on remote controller
FAN button
5
Press this button, Auto, Low, Middle, High speed can be circularly selected. After
6
Press this button, to set up swing angle, which circularly changes as below:
This is an universal use remote controller. If remote controller sends the following three kinds of status that the swing status of main unit will be:
When the guide louver start to swing up and down, if turn off the Swing, the air guide louver will stop at current position.
which indicates the guide louver swings up and down between that all five positions.
powered on, Auto fan speed is default.
Note: Under the Dry mode, the fan speed isn't adjustable, low fan speed is imperative,
but when operating this button, the wireless adjustable, low fan speed is imperative.
button
7
Press this button, the clock can be set up, signal blink and display. Within 5 seconds, the value can be adjusted by pressing + or - button, if continuously press this button for 2 seconds above, in every 0.5 seconds, the value on ten place of Minute will be increased
1. During blinking, repress the Clock button, signal will be constantly displayed and it denotes the setting succeeded. After powered on,12:00 is defaulted to display and signal
is Clock value, otherwise is Timer value.
will be displayed. If there is signal be displayed that denotes the current time value
Middle fanLow fan
AUTO
High fan
OFF
CLOCK button
8
Timer On setting: Signal “ON” will blink and display, signal will conceal, the numerical section will become the timer on setting status. During 5 seconds blink, by pressing + or
will be increased or decreased 1 minute. Hold pressing + or - button, 2 seconds later, it
in the one place of minute, then the one place is constant, ten numbers change in the tens place of minute at 2.5 seconds speed and carry. During 5s blink, press the Timer button, the timer setting succeeds. The Timer On has been set up, repress the timer On button, the Timer On will be canceled. Before setting the Timer, please adjust the Clock to the current actual time.
quickly change, the way of change is: During the initial 2.5 seconds, ten numbers change
- button to adjust the time value of numerical section, every press of that button, the value
TIMER ON button
11
Introduction for buttons on remote controller
X-FAN button
9
Pressing X-FAN button in COOL or DRY mode, the icon is displayed and the
TEMP button
10
Press this button, could select displaying the indoor setting temperature or indoor
TIMER OFF button
11
Once press this key to enter into TIMER OFF setup, in which case the TIMER OFF
TURBO button
12
In Cool or Heat mode, press this button can turn on or turn off the Turbo function.
SLEEP button
13
Press this button, Sleep On and Sleep Off can be selected. After powered on, Sleep Off is defaulted. After the unit is turned off, the Sleep function is canceled. After Sleep function set up, the signal of Sleep will display.In this mode, the time of timer can be adjusted. Under Fan and Auto modes, this function is not available.
After turned on the Turbo function, its signal will be displayed. When switching the mode or changing fan speed, this function will be canceled automatically.
icon will blink. The method of setting is the same as for TIMER ON.
ambient temperature. When the indoor unit firstly power on it will display the setting temperature, if the temperature's displaying status is changed from other status to
control signal that will return to display the setting temperature. if the users haven't set up the temperature displaying status, that will display the setting temperature. (This function is applicable to partial of models)
After powered on, the setting temperature displaying is defaulted, (according to cust­omers requirements to display, if there is no requirement that will default to display
Press this button, (When displaying ), will display presetting temperature; (when displaying ) will display indoor ambient temperature, current displaying status will not be changed. If current displays indoor ambient temperature, if received the other remote control signal, it will display presetting temperature, 5s later, will back to display the ambient temperature. (This function is applicable to partial ofmodels)
the presetting temperature and there is no icon displayed on wireless remote control).
" ", displays the ambient temperature, 5s later or within 5s, it receives other remote
indoor fan will continue operation for 10 minutes in order to dry the indoor unit even though you have turned off the unit. After energization, X-FAN OFF is defaulted. X-FAN is not available in AUTO, FAN or HEAT mode.
12
Introduction for buttons on remote controller
Introduction for special function
14
Press this button to select LIGHT on or off in the displayer. When the LIGHT on is set, the icon will be displayed and the indicator light in the displayer will be on. When the LIGHT off is set, the icon will be displayed and the indicator light in the displayer will be off.
LIGHT button
About X-FAN function
This function indicates that moisture on evaporator of indoor unit will be blowed after
About AUTO RUN
When AUTO RUN mode is selected, the setting temperature will not be displayed on
About turbo function
If start this function, the unit will run at super-high fan speed to cool or heat quickly so
About Blow over heat (This function is applicable to partial of models)
When the unit is running in Heat mode or Auto Heat mode, compressor and indoor fan is running, to turn the unit off, the compressor, outdoor fan will stop running. The upper and lower guide board rotate to horizontal position, then the indoor fan will run at low fan speed, 10s later, the unit will turn off.
that the ambient temp. approachs the preset temp. as soon as possible.
the LCD, the unit will be in accordance with the room temp. automatically to select the suitable running method and to make ambient comfortable.
the unit is stopped to avoid mould.
1. Having set X-FAN function on: After turning off the unit by pressing ON/OFF button
indoor fan will continue running for about 10 min. at low speed. In this period, press X-FAN button to stop indoor fan directly.
2. Having set X-FAN function off: After turning off the unit by pressing ON/OFF button,
the complete unit will be off directly.
13
Introduction for special function
About new function of defrosting
General operation
Under switch-off state, hold MODE key for 2 seconds to enter or exit defrost H1 func­tion. After being energized, the defrost H1 function is defaulted off. When entering defrost H1 function, the double-8 nixie tube will display H1 under switch-off state. When adjusting to heat mode, the double-8 nixie tube will display in flash for 5 seconds at a frequency of 1 count/sec. After the flash is ended, the remote controller will display the preset heating temperature. Within these 5 seconds, press of +, - or TIMER key will cancel the display H1, while the double-8 nixie tube will display the preset temperature. To switch the display of temperature between Celsius and Fahrenheit after entering defrost H1 function, the temperature value to be switched will be displayed firstly before display of H1 after 5 seconds.
1. After powered on, press ON/OFF button, the unit will
Optional operation
1. Press SLEEP button, to set sleep.
2. Press TIMER ON and TIMER OFF button, can set
3. Press LIGHT button, to control the on and off of the
4. Press TURBO button, can realize the ON and OFF
start to run. (Note: when it is powered on, the guide
2. Press MODE button, select desired running mode.
3. Pressing + or - button,to set the desired temperature.
4. Pressing FAN button, set fan speed, can select AUTO
5. Pressing button, to select the swing.
louver of main unit will close automatically.)
(It isunnecessary to set the temp. at AUTO mode.)
FAN, LOW, MID and HIGH.
the scheduled timer on or timer off.
displaying part of the unit (This function may be not available for some units).
of TURBO function.
Operation guide
14
Replacement of batteries in remote controller
1. Press the back side of remote controller marked
the cover of battery box along the arrow direction.
2. Replace two 7# (AAA 1.5V) dry batteries, and make sure the position of "+" polar and "-" polar are correct.
3. Reinstall the cover of battery box.
battery
Cover of battery box
remove
reinstall
● During operation, point the remote control signal sender at the receiving window on indoor unit.
The distance between signal sender and receiving window should be no more than 8m, and there should be no obstacles between them.
or wireless telephone; remote controller should be close to indoor unit during operation.
● Replace new batteries of the same model when replacement is required.
● When you don’t use remote controller for a long time, please take out the
batteries.
● If the display on remote controller is fuzzy or there’s no display, please replace batteries.
NOTICE
15
Emergency operation
Clean and maintenance
air conditioner. When the air conditioner is turned on, it will operate under auto mode.
aux. button
panel
WARNING:
Use insulated object to press the auto button
If remote controller is lost or damaged, please use auxiliary button to turn on or turn off the air conditioner. The operation in details are as below:
WARNING
NOTICE:
Turn off the air conditioner and disconnect the power before cleaning the air conditioner to avoid electric shock.
■ Do not wash the air conditioner with water to avoid electric shock.
■ Do not use volatile liquid to clean the air conditioner.
Clean surface of indoor unit
When the surface of indoor unit is dirty, it is recommended to use a soft dry cloth or wet cloth to wipe it.
● Do not remove the panel when cleaning it.
16
Clean and Maintenance
Clean lter
1
2
3
4
Open panel
Remove lter
Clean lter
Install lter
Pull out the panel to a certain
angle as shown in the g.
Remove the lter as in­dicated in the g.
● Use dust catcher or water to clean the lter.
● When the lter is very dirty, use
the water (below 45℃) to clean it, and then put it in a shady and cool place to dry.
Install the lter and then close the
panel cover tightly.
■ The lter should be cleaned every three months. If there is much dust in the
operation environment, clean frequency can be increased.
■ After removing the lter, do not touch ns to avoid injury.
■ Do not use re or hair dryer to dry the lter to avoid deformation or re hazard.
WARNING
17
Clean and Maintenance
1. Check whether air inlets are blocked.
2. Check whether air switch,plug and socket are in good condition.
3. Check whether filter is clean.
4. Check whether drainage pipe is damaged.
1. Disconnect power supply.
2. Clean filter and indoor unit’s panel.
Notice for recovery
1. Many packing materials are recyclable materials. Please dispose them in appropriate recycling unit.
2. If you want to dispose the air conditioner, please contact local dealer or consultant service center for the correct disposal method.
NOTICE: Checking before use-season
NOTICE: Checking after use-season
18
Malfunction analysis
General phenomenon analysis
Please check below items before asking for maintenance. If the malfunction still
can’t be eliminated, please contact local dealer or qualied professionals.
Phenomenon Check items Solution
Indoor unit can’t receive remote controller’s signal or remote controller has no action.
● Whether it's interfered severely
(such as static electricity, stable voltage)?
● Whether remote controller is
within the signal receiving range?
● Whether there are obstacles?
● Whether remote controller is
pointing at the receiving window?
● Is sensitivity of remote contro­ ller low; fuzzy display and no
display?
● No display when operating
remote controller?
● Fluorescent lamp in room?
● Pull out the plug. Reinsert
the plug after about 3min, and then turn on the unit again.
● Signal receiving range is 8m.
● Remove obstacles.
Select proper angle and point the remote controller at the re­ ceiving window on indoor unit.
● Check the batteries. If the
power of batteries is too low, please replace them.
● Take the remote controller
close to indoor unit.
● Turn off the uoresent lamp
and then try it again.
● Check whether remote cont-
roller appears to be damaged. If yes, replace it.
No air emitted from indoor unit
● Air inlet or air outlet of indoor
unit is blocked?
● Eliminate obstacles.
● Under heating mode, indoor
temperature is reached to set temperature?
● After reaching to set temper-
ature, indoor unit will stop bl­ owing out air.
● Heating mode is turned on just
now?
● In order to prevent blowing
out cold air, indoor unit will be started after delaying for sev­ eral minutes, which is a nor­ mal phenomenon.
19
Malfunction analysis
● Power failure?
● Is plug loose?
● Air switch trips off or fuse is
burnt out?
● Wiring has malfunction?
● Unit has restarted immediately
after stopping operation?
● Whether the function setting
for remote controller is correct?
● Reset the function.
● Wait for 3min, and then turn
on the unit again.
● Ask professional to replace it.
● Ask professional to replace
air switch or fuse.
● Reinsert the plug.
● Wait until power recovery.
Air condit­ioner can’t operate
Mist is em­itted from indoor unit’s air outlet
● Indoor temperature and hum-
idity is high?
● Because indoor air is cooled
rapidly. After a while, indoor temperature and humidity will be decrease and mist will disappear.
Phenomenon
Check items Solution
Set temper­ature can’t be adjusted
● Unit is operating under auto
mode?
● Temperature can’t be adju-
sted under auto mode. Please switch the operation mode if you need to adjust temperature.
● Your required temperature
exceeds the set temperature range?
● Set temperature range:
16℃~30℃.
Cooling (heating) effect is not good.
● Voltage is too low?
● Wait until the voltage
resumes normal.
● Filter is dirty? ● Clean the lter.
● Set temperature is in proper
range?
● Adjust temperature to proper
range.
● Door and window are open? ● Close door and window.
20
Malfunction analysis
Phenomenon Check items Solution
Odours are emitted
● Whether there’s odour source,
such as furniture and cigarette, etc.
● Eliminate the odour source.
● Clean the lter.
“Water
owing”
noise
● Air conditioner is turned on or
turned off just now?
● The noise is the sound of refrigerant owing inside
the unit, which is a normal phenomenon.
Cracking noise
● Air conditioner is turned on or
turned off just now?
● This is the sound of friction
caused by expansion and/or contraction of panel or other parts due to the change of temperature.
Air conditio­ner operates abnormally suddenly
● Whether there’s interference,
such as thunder, wireless devices, etc.
● Disconnect power, put back
power, and then turn on the unit again.
21
Error code
E5
E8
U8
H6
C5
F1 F2
Troubleshooting
It can be eliminated after restarting the unit. If not, please
It can be eliminated after restarting the unit. If not, please
It can be eliminated after restarting the unit. If not, please
It can be eliminated after restarting the unit. If not, please
■ When below phenomenon occurs, please turn off air conditioner and discon-
for service.
● Power cord is overheating or damaged.
There’s abnormal sound during operation.
Air switch trips off frequently.
Air conditioner gives off burning smell.
● Indoor unit is leaking.
■ If the air conditioner operates under abnormal conditions, it may cause
Malfunction analysis
Error Code
● When air conditioner status is abnormal, temperature indicator on indoor unit will blink to display corresponding error code. Please refer to below list for identic-
ation of error code.
Note: If there're other error codes, please contact qualified professionals for service.
WARNING
22
Installation dimension diagram
At least 250cm
At least 15cm
At least 300cm
Space to the ceiling
Space to the obstruction
At least 15cm
At least 15cm
Space to the wall
Space to the wall
23
Tools for installation
1. There should be no obstruction near air inlet .
2. Select a location where the condensation water can be dispersed easily and
won't affect other people.
3. Select a location which is convenient to connect the outdoor unit and near the power socket.
4. Select a location which is out of reach for children.
5. The location should be able to withstand the weight of indoor unit and won't
increase noise and vibration.
6. The appliance must be installed 2.5m above oor.
7. Don't install the indoor unit right above the electric appliance.
8. Please try your best to keep way from uorescent lamp.
Selection of installation location
1 Level meter 2 Screw driver 3 Impact drill 4 Drill head 5 Pipe expander 6 Torque wrench
7 Open-end wrench 8 Pipe cutter
9 Leakage detector
10 Vacuum pump 11 Pressure meter
12 Universal meter
13 Inner hexagon spanner 14 Measuring tape
Note:
● Please contact the local agent for installation.
● Don't use unqualied power cord.
Basic requirement
Indoor unit
Installing the unit in the following places maycause malfunction. If it is unavoidable, please consult the local dealer:
1. The place with strong heat sources,
vapors, ammable or explosive gas
, or
volatile objects spread in the air.
2. The place with high-frequency devices (such as welding machine, medical equipment).
3. The place near coast area.
4.
The place with oil or fumes in the air.
5. The place with sulfureted gas.
6. Other places with special circumstances.
7. Do not use the unit in the immediate surroundings of a laundry a bath a shower or a swimming pool.
24
Requirements for electric connection
Safety precaution
Grounding requirement
1. Must follow the electric safety regulations when installing the unit.
2. According to the local safety regulations, use qualied power supply circuit and
air switch.
3. Make sure the power supply matches with the requirement of air conditioner. Unstable power supply or incorrect wiring or malfunction. Please install proper power supply cables before using the air conditioner.
4. Properly connect the live wire, neutral wire and grounding wire of power socket.
5. Be sure to cut off the power supply before proceeding any work related to electricity and safety.
6. Do not put through the power before nishing installation.
7. If the supply cord is damaged, it must be replaced by the manufacturer, its
service agent or similarly qualied persons in order to avoid a hazard.
8. The temperature of refrigerant circuit will be high, please keep the interconnec­ tion cable away from the copper tube.
9. The appliance shall be installed in accordance with national wiring regulations.
1. The air conditioner is the rst class electric appliance. It must be properly grounding with specialized grounding device by a professional. Please make
sure it is always grounded effectively, otherwise it may cause electric shock.
2. The yellow-green wire in air conditioner is grounding wire, which can't be used
for other purposes.
3. The grounding resistance should comply with national electric safety regulations.
4. The appliance must be positioned so that the plug is accessible.
5. An all-pole disconnection switch having a contact separation of at least 3mm in
all poles should be connected in xed wiring.
25
Installation of indoor unit
Step one: choosing installation location
Step two: install wall-mounting frame
rm it with the client.
1. Hang the wall-mounting frame on the wall; adjust it in horizontal position with the
plastic expansion particles in the holes.
3. Fix the wall-mounting frame on the wall with tapping screws (ST4.2X25TA) and
.
1. Choose the position of piping hole according to the direction of outlet pipe. The position of piping hole should be a little lower than the wall-mounted frame, shown as below.
Step three: open piping hole
Left
Wall
Φ70mm
Right
Mark in the middle of it
Level meter
Rear piping hole
Wall
Space
to the
wall
above
150mm
Space
to the
wall
above
150mm
Φ70mm
Rear piping hole
2. Open a piping hole with the diameter of Φ55 or Φ70 on the selected outlet pipe position.In order to drain smoothly, slant the piping hole on the wall slightly
downward to the outdoor side with the gradient of 5-10°.
18K:
24K:
Left
Wall
Φ55mm
Right
Mark in the middle of it
Level meter
Rear piping hole
Wall
Space
to the
wall
above
150mm
Space
to the
wall
above
150mm
Φ55mm
Rear piping hole
26
1. Aim the pipe joint at the corresponding bellmouth.
2. Pretightening the union nut with hand.
3. Adjust the torque force by referring to the following sheet. Place the open-end wrench on the pipe joint and place the torque wrench on the union nut. Tighten the union nut with torque wrench.
2. When select leading out the pipe from left or right, please cut off the corresponding hole on the bottom case.
cut off the hole
left right
1. The pipe can be led out in the direction of right, rear right, left or rear left.
left
rear left
right
rear right
Step four: outlet pipe
Installation of indoor unit
union nutpipe joint
pipe
Indoor
5-10
outdoor
Φ70
Φ55/
Note:
● Pay attention to dust prevention and take relevant safety measures when
opening the hole.
The plastic expansion particles are not provided and should be bought
locally.
27
nection pipe with insulating pipe, and then wrap it with tape.
Step six: install drain hose
insulating pipe
1. Connect the drain hose to the outlet pipe of
2. Bind the joint with tape.
outlet
pipe
drain hose
drain hose
tape
outlet pipe
drain hose
insulating pipe
Add insulating pipe in the indoor drain hose in order to prevent condensation.
The plastic expansion particles are
1. Open the panel, remove the screw on the wiring cover and then take down the cover.
wiring cover
screw
panel
Step seven: connect wire of indoor unit
4. Wrap the indoor pipe and joint of con-
Installation of indoor unit
torque wrench
open-end wrench
indoor pipe
pipe
union nut
Hex nut diameter Tightening torque (N.m)
Φ 6
Φ 9.52
Φ 12 Φ 16 Φ 19
30~40 45~55
60~65 70~75
15~20
indoor unit.
Note:
not provided.
28
4. Put wiring cover back and then tighten the screw.
5. Close the panel.
Installation of indoor unit
Note:
All wires of indoor unit and outdoor unit should be connected by a professional.
for a new one. Avoid extending the wire by yourself.
installation.
● For the air conditioner without plug, an air switch must be installed in the line.
The air switch should be all-pole parting and the contact parting distance should
be more than 3mm.
3. Remove the wire clip; connect the power connection wire to the wiring terminal according to the color; tighten the screw
with wire clip.
power connection wire
cable-cross hole
2. Make the power connection wire go through the cable-cross hole at the back
of indoor unit and then pull it out from
the front side.
N(1) 2 32
black
Outdoor unit connection
yellow­green
blue brown
29
Installation of indoor unit
Step eight: bind up pipe
1. Bind up the connection pipe, power cord and drain hose with the band.
indoor unit
gas pipe
indoor and
outdoor power cord
liquid pipe
drain hose
band
2. Reserve a certain length of drain hose and power cord for installation when binding them. When binding to a certain degree, separate the indoor power and then separate the drain hose.
3. Bind them evenly.
4. The liquid pipe and gas pipe should be bound separately at the end.
Note:
● The power cord and control wire can't be crossed or winding.
● The drain hose should be bound
at the bottom.
drain hose
band
connection pipe
indoor power cord
Step nine: hang the indoor unit
1. Put the bound pipes in the wall pipe and then make them pass through the wall hole.
2. Hang the indoor unit on the wall-mounting frame.
3. Stuff the gap between pipes and wall hole with sealing gum.
4. Fix the wall pipe.
5. Check if the indoor unit is installed firmly and closed to the wall.
Note:
● Do not bend the drain hose too excessively in order to prevent blocking.
indoor
outdoor
wall pipe
sealing gum
upper hook
lower hook of wall-mounting frame
30
Check after installation
Test operation
● Check according to the following requirement after nishing installation.
Items to be checked Possible malfunction
Has the unit been installed rmly? The unit may drop, shake or emit noise. Have you done the refrigerant leakage
test?
It may cause insufcient cooling
(heating) capacity.
Is heat insulation of pipeline sufcient?
It may cause condensation and water dripping.
Is water drained well?
It may cause condensation and water dripping.
Is the voltage of power supply accord­ing to the voltage marked on the nameplate?
It may cause malfunction or damaging the parts.
Is electric wiring and pipeline installed correctly?
It may cause malfunction or damaging the parts.
Is the unit grounded securely? It may cause electric leakage.
Does the power cord follow the speci­cation?
It may cause malfunction or damaging the parts.
Is there any obstruction in the air inlet and outlet?
It may cause insufcient cooling
(heating) capacity.
The dust and sundries caused during installation are removed?
It may cause malfunction or damaging the parts.
The gas valve and liquid valve of connection pipe are open completely?
It may cause insufcient cooling
(heating) capacity.
1. Preparation of test operation
● The client approves the air conditioner.
● Specify the important notes for air conditioner to the client.
2. Method of test operation
● Put through the power, press ON/OFF button on the remote controller to start
operation.
● Press MODE button to select AUTO, COOL, DRY, FAN and HEAT to check
whether the operation is normal or not.
● If the ambient temperature is lower than 16℃, the air conditioner can’t
start cooling.
31
1. Standard length of connection pipe
● 5m, 7.5m, 8m.
4. The additional refrigerant oil and refrigerant charging required after prolonging connection pipe
After the length of connection pipe is prolonged for 10m at the basis of standard length, you should add 5ml of refrigerant oil for each additional 5m
of connection pipe.
The calculation method of additional refrigerant charging amount (on the basis of liquid pipe):
Basing on the length of standard pipe, add refrigerant according to the requirement as shown in the table. The additional refrigerant charging amount per meter is different according to the diameter of liquid pipe. See the
following sheet.
Additional refrigerant charging amount = prolonged length of liquid pipe × additional refrigerant charging amount per meter
Cooling
capacity
Cooling
capacity
5000Btu/h
(1465W)
24000Btu/h
(7032W)
7000Btu/h
(2051W)
28000Btu/h
(8204W)
9000Btu/h
(2637W)
36000Btu/h
(10548W)
12000Btu/h
(3516W)
42000Btu/h
(12306W)
18000Btu/h
(5274W)
48000Btu/h
(14064W)
Max height difference
Max height difference
Max length of connec­tion pipe
Max length of connec­tion pipe
15 255 10
15 305 10
15 305 20
20 3010 20
25 3010 20
2. Min. length of connection pipe is 3m.
3. Max. length of connection pipe and max. high difference.
Configuration of connection pipe
32
Additional refrigerant charging amount for R22, R407C, R410A and R134a
Diameter of connection pipe
Liquid pipe(mm) Gas pipe(mm)
Φ6
Φ6 or Φ9.52
Φ12
Φ16
Φ19
Φ22.2
Φ9.52 or Φ12
Φ16 or Φ19
Φ19 or Φ22.2
Φ25.4 or Φ31.8
_
_
Cooling only(g/m) Cooling and heating(g/m)
15
15
30
60
250 250
350350
120
120
50
20
Outdoor unit throttle
Conguration of connection pipe
33
Φ6 - 6.35(1/4")
Φ9.52(3/8")
Φ12-12.7(1/2") Φ15.8-16(5/8")
1.3 0.7
1.6 1.0
1.8 1.0
2.4 2.2
Pipe expanding method
Note:
Improper pipe expanding is the main cause of refrigerant leakage. Please expand the pipe according to the following steps:
A: Cut the pipe
● Conrm the pipe length according to
the distance of indoor unit and outdoor unit.
● Cut the required pipe with pipe cutter.
pipe
pipe cutter
leaning uneven burr
B: Remove the burrs
● Remove the burrs with shaper and
prevent the burrs from getting into the pipe.
downwards
pipe
shaper
C: Put on suitable insulating pipe
D: Put on the union nut
● Remove the union nut on the indoor
connection pipe and outdoor valve; install the union nut on the pipe.
union pipe
pipe
E: Expand the port
● Expand the port with expander.
Note:
● "A" is different according to the
diameter, please refer to the sheet below:
expander
hard mold
pipe
F: Inspection
● Check the quality of expanding port.
If there is any blemish, expand the port again according to the steps above.
the length is equal
improper expanding
leaning
damaged
surface
crack uneven
thickness
smooth surface
Outer diameter
(mm)
A(mm)
Max Min