INVENTOR E2VI-09, E2VO-09, E2VI-12, E2VO-12, E2VI-24 Owner's Manual

...
Models
E2VI-24/E2VO-24
Wall Mounted Unit
Owner’s Manual
66129913344
Thank you for choosing INVENTOR air conditioning system. For correct use of this unit, please read this manual carefully and keep it for future reference.
CONTENTS
Operation and maintenance
Notices for operation ...............................................................1
Notices for use ..................................................................... 3
Names and functions of each part ............................................ 5
Operation of Remote Controller................................................ 6
Emergency operation ........................................................... 11
Clean and care ................................................................... 12
Troubleshooting .................................................................. 14
Installation service
Notices for installation .......................................................... 17
Installation dimension diagram Install indoor unit
Install outdoor unit
Check after installation and test operation ................................. 24
Installation and Maintenance of Healthy Filter ............................ 25
Install snow guard (Optional) ................................................. 26
Configuration of connection pipe and additional volume of refrigerant
................................................................ 20
............................................................... 23
............................................... 19
.............27
This symbol stands for the items should be forbidden.
The products in this manual may be different with the real one, according to different models, some models have displayer and some models without displayer, the position and shape of the displayer please refer to the real one.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance
by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmental safe recycling.
This symbol stands for the items should be followed.
Operation and maintenance - notices for operation
Earth: The ground be connected!
If not, please ask the qualified person­nel to install. Furthermore, don't conn­ect each wire to the gas pipe, water pipe, drainage pipe or any other impr­oper places.
Be sure to pull out the power
plug when not using the air co­nditioner for a long time.
Otherwise, the accumulated dust may cause fire or electric shock.
Select the most appropriate
temperature.
Keep room cool­er than outside about 5 degree.
It can preclude the electricity wasted.
Don't leave windows and
doors open for a long time while operating the air
conditioner.
It can decrease the air conditioning capacity.
Please note whether the installed
stand is firm enough or not.
If it is damaged, it may lead to the fall of the unit and cause
the injury.
Don't block the air intake or outlet
vents of both the outdoor and indoor units.
It can decrease the air conditioning capacity or cause a malfunction.
Don't step on the top of the
outdoor unit or place something on it.
As falling of can be dangerous.
f the outdoor unit
Keep combustible spray away
from the units more than 1m.
It can cause a fire or explosion.
Don't attempt to repair
the air conditioner by yourself.
The wrong repair will lead to an electric shock or fire, so you should contact the service center to repair
.
- 1 -
Notices for operation
If the supply cord is damaged, it must be replaced
by the manufacturer or its service agent or a
similarly qualified person in order to avoid a hazard.
The airflow direction can be adjusted appro-
priately. At operating, adjust the vertical airflow direction by adjusting the louvers of upward/do­wnward direction. And then, hold two ends of left and right louver to adjust the horizontal air­flow.
Don't insert your hands or stick into the air
intake or outlet vents.
Otherwise it will cause accident.
Don't apply the cold wind to the body for a
long time.
It can cause the health problems.
Splashing water on the air conditioner can cause an electric shock and malfunction.
Louver of left/right direction Louver of upward/
Don't blow the wind to animals and plants
directly. It can cause a bad influence to them.
Don't use the air conditioner for other purposes,
such as drying clothes, preserving foods, etc.
Don't place a space heater near the air conditioner.
downward direction.
Or CO toxicosis may occur for imcomplete burning.
- 2 -
Notices for use
Working principle and special functions for cooling
Principle:
Air conditioner absorbs heat in the room and transmit to outdoor and discharged, so that indoor ambient temperature decreased, its cooling capacity will increase or decrease by outdoor ambient temperature.
Anti-freezing function:
If the unit is running in COOL mode and in low temperature, there will be frost formed on the heat exchanger, when indoor heat exchanger temperature decreased below 0 , the indoor unit microcomputer will stop compressor running and protect the unit.
Working principle and special functions for heating
Principle:
Air conditioner absorbs heat from outdoor and transmits to indoor, in this way to increase
*
room temperature. This is the heat pump heating principle, its heating capacity will be reduced due to outdoor temperature decrease. If outdoor temperature becomes very low, please operate with other heating equipments.
*
Defrosting:
When outdoor temperature is low but high humidity, after a long while running, frost will
*
form on outdoor unit, that will effect the heating effect, at this time, the auto defrosting function will act, the heat running will stop for 8-10mins. During the auto defrosting, the fan motors of indoor unit and outdoor unit will stop.
*
During the defrosting, the indoor indicator flashes, the outdoor unit may emit vapor.
*
This is due to the defrosting, it isn't malfunction. After defrosting finished,the heating will recover automatically.
*
Anti-cool wind function:
In "Heat" mode, under the following three kinds of state, if indoor heat exchanger doesn't arrive at certain temp., indoor fan will not act, in order to prevent cool wind blowing(within 2 mins):
1. Heating starts. 2. After Auto Defrost finished. 3. Heating under the low temperature.
Rest Heat Blow
In the following situations, the indoor unit may still run for some time, to blow out the rest heat of the indoor unit.
1. In HEAT mode, the temperature reaches the setting value, the compressor stops and the indoor fan still run for 60s.
2. In HEAT mode, if you turn off the unit, the compressor stops and the indoor fan still run for 10s.
- 3 -
Notices for use
Working temperature range
Indoor sideDB/WB(oC)
~
43.
32/23
27/-
Maximum cooling Maximum heating
The operating temperature range (outdoor temperature) for cooling unit is 18 for cooling and heating unit is -7
Outdoor sideDB/WB(oC)
43/26
24/18
~ 43℃;
- 4 -
Names and functions of each part
Indoor unit
SET TEMP
Cool Heat
ON/OFF
Outdoor unit
Air in
Air in
Air out
Dry Run
Receive window
Power cable(1) Remote controller(2) Front panel(3) Filter(4) Guide louver(5) Wall pipe(6) Bind tape(7) Connection wire(8) Drainage pipe(9)
Air out
(8)
(9)
- 5 -
Operation of Remote Controller
1
ON/OFF
Press it to start or stop operation.
2
MODE
Press it to select operation mode (AUTO/COOL/DRY/FAN/HEAT).
3
: Press it to decrease temperature
-
4
+
: Press it to increase temperature
5
FAN
Press it to set fan speed.
6
Press it to set up & down swing angle.
7
HEALTH SAVE
Press it to turn on or off health function.
1
ON/OFF
AUTO
FAN
HEALTH
AIR
HUMIDITY
FILTER
TURBO
OPER
X-FAN
HOUR
ON/OFF
MODE
2
43
setting.
setting.
( page 9)
7 9
12
5
X-FAN
TURBO
FAN
10
13
TEMP
SLEEP
TIMER
LIGHT
6
8
11
14
8
Press it to set left & right swing angle.
9
X-FAN ( page 9)
10
TEMP( page 9)
11
TIMER
Press it to set timer ON/ timer OFF.
12
TURBO( page 10)
13
SLEEP( page 10)
14
LIGHT
Press it to turn on/off the light.
- 6 -
Operation of Remote Controller
16 17
18
15
MODE icon:
If MODE button is pressed, current operation mode icon
(AUTO), ( COOL),
(DRY), (FAN) or (HEAT only for heat pump models) will
show.
16
LOCK icon:
is displayed by pressing "+"
and "-" buttons simultaneously. Press them again to clear the display.
17
LIGHT icon:
is displayed by pressing the LIGHT button. Press LIGHT button again to clear the display.
18
SLEEP icon :
is displayed by pressing
the SLEEP button. Press this button again to clear the display.
19
TEMP icon:
Pressing TEMP button, (set temperature), ambient temperature) (outdoor ambient temperature) and blank is displayed circularly.
NOTE: “ ” function is applicable to partial of models.
(indoor
AUTO
FAN
HEALTH
AIR
HUMIDITY
FILTER
TURBO
191520
OPER
X-FAN
24
23
HOUR
ON/OFF
22 21
20
Up & down swing icon:
is displayed when pressing
the
up & down swing
Press this button again to clear the display.
21
Left & right swing icon:
is displayed when pressing the
left & right swing
button again to clear the display.
22
SET TIME display:
After pressing TIMER button,
ON or OFF will blink.This area will show the set time.
23
DIGITAL display:
This area will show the set tempe­rature. In SAVE mode,"SE" will be
displayed.
24
FAN SPEED display:
Press FAN button to select the desired fan speed setting(AUTO-
Low-Med-High).Your selection will be displayed in the LCD windows, except the AUTO fan speed.
button.
button.Press this
- 7 -
Loading...
+ 21 hidden pages