CONTENTS
Operation and maintenance
Notices for operation
■ .............................1
■ ....................................3
Notices for use
Names and functions of each part
■ ...................4
Operation of wireless remote control
■ .....................5
Emergency operation
■ ..............................10
Clean and care
■ ...................................11
■ ...................................13
Troubleshooting
...
...
Installation service
Notices for installation
■ ...............................16
Installation dimension diagram
■
■ ...............................19
Install indoor unit
Install outdoor unit
■ ..............................21
■ .................23
Check after installation and test operation
■
Installation and Maintenance of Healthy Filter
...
...
...........
..............18
..............24
The figures in this manual may be different with the material objects, please refer
to the material objects for reference.
This symbol stands for the items
should be forbidden
Do not dispose this product as unsorted municipal waste.
Collection of such waste separately for special treatment
is necessary.
This symbol stands for the items
should be followed
Notices for operation
Please read the following carefully before operating
★
When the voltage
is very high, the
components would be easily
damaged, when the voltage
is very low, the compressor
vibrates terribly and that the
refrigerant system will be
damaged, the compressor
and electric components
cannot work, the voltage
should be stable; there
shouldn’t be big fluctuation.
Don’t leave windows
★
and doors open for
a long time while operating
the air conditioner.
It can decrease the air
conditioning capacity.
Be sure to pull out
★
the power plug as
the air conditioner not in use
for a long time.
Otherwise, the accumulated
dusts that may cause over
heating or fire.
★
Don't block the air
intake or outlet vents
of both the outdoor and indoor
units.
It can decrease the air conditioning
capacity or cause a malfunction.
Never splice the
power cord or use
an extended cord.
It can cause overheating or
fire.
★
The power supply
must adopt the
special circuit that with air
switch protection and assure
it has enough capacity.
The unit will be turned on or
off according to your requirement
automatically, please do notturn on or turn off the unit
frequently, otherwise disadv-antage effect may be caused
to the unit.
★
When having a
burning smell or
smoke, please turn off the
power supply and contact
with the service center.
If the abnormity still exists,
the unit may be damaged,
and may cause electric
shock or fire.
★Keep combustilble
spray away from the
units more than 1m.
It can cause a fire or explosion
1
Don’t attempt to
★
repair the air
conditioner by yourself.
The wrong repair will lead to
an electric shock or fire, so
you should contact the service
center to repair.
Notices for operation
Please don't cut off or damage the
★
power cords and control cords.
If they are damaged, please ask the qualified
personnel to change them.
Don’t insert your hands or stick into
★
the air intake or outlet vents.
Don’t apply the cold wind to
★
the body for a long time.
It can cause the health problems.
To adjust the airflow direction
★
appropriately. When operating
the unit, to adjust the vertical and lateral air
flow direction by use of remote controller.
Swing louver
Don’t blow the wind to animals
★
and plants directly. It can cause
a bad influence to them.
★
Don’t use the air conditioner
for other purposes, such as
drying clothes, preserving foods, etc.
Guide louver
Splashing water on the air
★
conditioner can cause an electric
shock and malfunction.
Don’t place a space heater
★
near the air conditioner.
2
Notices for use
Working principle and special functions for cooling
Principle:
Air conditioner absorbs heat in the room and transmit to outdoor and discharged, so that
indoor ambient temperature decreased, its cooling capacity will increase or decrease by
outdoor ambient temperature.
Anti-freezing function
If the unit is running in COOL mode and in low termperature, there will be frost formed on
the heat exchanger, when indoor heat exchanger temperature decreased below
indoor unit microcomputer will stop compressor running and protect the unit.
Working principle and special functions for heating
Principle:
Air conditioner absorbs heat from outdoor and transmits to indoor, in this way to increase
*
room temperature. This is the heat pump heating principle, its heating capacity will be
reduced due to outdoor temperature decrease.
If outdoor temperature becomes very low, please operate with other heating equipments.
*
Defrosting:
*
When outdoor temperature is low but high humidity, after a long while running, frost will
form on outdoor unit, that will effect the heating effect, at this time, the auto defrosting
function will act, the heat running will stop for 8-10mins.
*
During the auto defrosting, the fan motors of indoor unit and outdoor unit will stop.
*
During the defrosting, the indoor indicator flashes, the outdoor unit may emit vapor.
This is due to the defrosting, it isn't malfunction.
*
After defrosting finished,the heating will recover automatically.
℃
0 , the
Anti-cool wind function:
In Heat mode, the following three kinds of status, if indoor heat exchanger hasn't achieve
certain temperature that indoor fan motor will not start, in this way to prevent blowing cool
wind (within 3mins):
1.Heat operation just startedup. 2.After Auto defrosting operation is finished.
3.Heating under low temperature.
The climate type of this unit is according to the nameplate.
3
Names and functions of each part
Indoor unit
⑶
Outdoor unit
⑵
⑷
Air in
Air in
Air out
⑴
⑸
⑼
⑹
⑴
⑵
⑶
⑷
⑸
⑹
⑺
⑻
⑼
Power cable
Front panel
Filter
Guide louver
Wall pipe
Bind tape
Connection wire
Drainage pipe
Remote control
Air out
⑺
⑻
4
遥控器各按键的名称及作用
Operation of wireless remote control
Name and function of wireless remote control
Note: Be sure that there are no obstructions between receiver and remote controller;
Don't drop or throw the remote control; Don't let any liquid in the remote control and
put the remote control directly under the sunlight or any place where is very hot.
Signal transmitter
Remote control
SLEEP
FAN
SLEEP button
●
Press this button, Sleep On and Sleep
Off can be selected. After powered on,
Off is defaulted. After the unit is
Sleep
turned off, the Sleep function is canceled.
After Sleep function set up, the signal of
Sleep will display. In this mode, the time of
timer can be adjusted. Under Fan and Auto
modes, this function is not available.
FAN button
●
Press this button, Auto, Low, Middle, High
speed can be circularly selected. After
powered on,Auto fan speed is default.
Under Dehumidify mode, Low fan speed
only can be set up.
MODE
ON/OFF button
●
Press this button, the unit will be turned on,
press it once more, the unit will be turned
off. When turning on or turning off the unit,
the Timer, Sleep function will be canceled,
but the presetting time is still remained.
MODE button
●
Press this button, Auto, Cool,Dry, Fan,
Heat mode can be selected circularly.
Auto mode is default while power on.
Under Auto mode,the temperature will not
be displayed; Under Heat mode, the
initial value is 28℃
modes,
the initial value is 25℃.
AUTO
COOL
DRY
FAN
HEAT
(Only for cooling and heating unit.)
82
(
o
;Under other
F)
(
o
F)
77
CLOCK
TEMP
Low fan
High fan
Middle fan
CLOCK button
●
Press this button, the clock can be set up,
signal blink and display.Within 5
seconds, the value can be adjusted by
pressing + or - button, if continuously
press this button for 2 seconds above,
in every 0.5 seconds, the value on ten place
of Minute will be increased 1. During blinking,
repress the Clock button, signal will be
constantly displayed and it denotes
the setting succeeded. After powered on,
12:00 is defaulted to display and signal
will be displayed. If there is signal
be displayed that denotes the current
time value is Clock value, otherwise is Timer
value.
TEMP button
●
Press this button, can set up temperature:
presetting temperature (to display room),
indoor ambient temperature (to display
indoor temperature), outdoor ambient
temperature (to display outdoor temperature),
and that will go around. It is defaulted that
there is no signal displaying. Remark:when
operating this button,the wireless remote
control displays the presetting temperature
all along.
5
Operation of wireless remote control
Names and functions of wireless remote control
Notice: This is a general use remote controller, it could be used for the air conditioners
with multifunction; For some function, which the model dosen't have, if press the
corresponding button on the remote controller that the unit will keep the original
running status.
Remote control
BLOW
BLOW button
●
Press this button, can turn on or turn off
the drying.In Cool and Dehumidifying mode,
press this button and will display "BLOW",
at this time the Blow is turned on. If repress
this button,"BLOW" will be concealed, at
this time the Blow function is turned off.
After powered on, Blow OFF is defaulted.
When operating the ON/OFF button, or
switching mode to Cool or Dehumidifying
mode,the Blow function will keep the original
status. If unit is turned off, Blow OFF only
can be set up and send the signal. In Auto,
Fan as well as Heat mode, Blow function
can not be set up and there is no "BLOW"
displaying.
+
LIGHT
+ button
●
For presetting temperature increasing.
Press this button,can set up the temperature,
when unit is on. Continuously press and
hold this button for more than 2 seconds,
the corresponding contents will be
changed rapidly, until unpress the button
then send the information, is displaying all along. In Auto mode, the temperature can not be set up, but operate this
button can send the signal. Centigrade
setting range :16-30; Fahrenheit scale
setting range 61-86.
-
- button
●
Presetting temperature can be decreased.
Press this button, the temperature can be
set up, continuously press this button
and hold for two seconds, the relative
contents can quickly change, until unhold
this button and send the order that the ℃
(oF)signal will be displayed all the time.
The temperature adjustment is unavailable under the Auto mode, but the order
can be sent by if pressing this button.
LIGHT button
●
Press this button at unit On or Off status,
Light On and Light Off can be set up.
After powered on, Light On is defaulted.
℃(℉)
TURBO
TURBO button
●
In Cool or Heat mode, press this button
can turn on or turn off the Turbo function.
After turned on the Turbo function, its
signal will be displayed. When switching
the mode or changing fan speed, this
function will be canceled automatically.
6
Operation of wireless remote control
Name and function of wireless remote control
Notice: This is a general use remote controller, it could be used for the air conditioners
with multifunction; For some function, which the model dosen't have, if press the
corresponding button on the remote controller that the unit will keep the original
running status.
Remote control
SWING UP and DOWN BUTTON
●
Press this button, to set up swing angle,
which circularly changes as below:
This is an universal use remote controller.
If remote controller sends the following
three kinds of status that the swing status
of main unit will be:
When the guide louver start to swing up and
down, if turn off the Swing, the air guide louver
will stop at current position.
●Press this button, Air On or Air Off can
OFF
which indicates the guide louver swings up
and down between that all five positions.
AIR BUTTON
be selected.
TIMER ON
TIMER OFF
I FEEL
TIMER ON BUTTON
●
Timer On setting: Signal “ON” will blink
and display, signal will conceal, the
numerical section will become the timer
on setting status. During 5 seconds blink,
by pressing + or - button to adjust the
time value of numerical section, every
press of that button, the value will be
increased or decreased 1 minute. Hold
pressing + or -button, 2 seconds later,
it quickly change, the way of change is:
During the initial 2.5 seconds, ten numbers
change in the one place of minute, then
the one place is constant, ten numbers
change in the tens place of minute at 2.5
seconds speed and carry. During 5s blink,
press the Timer On button, the timer setting
succeeds. The Timer On has been set up,
repress the timer On button, the Timer On
will be canceled. Before setting the
Timer, please adjust the Clock to the
current actual time.
TIMER OFF BUTTON
●Once press this key to enter into
TIMER OFF setup, in which case
the TIMER OFF icon will blink.
The method of setting is the same
as for TIMER ON.
HEALTH BUTTON
●
Press this button, can set up Health function
on or off. After unit is turned on, Health
function ON is defaulted.
I FEEL BUTTON
●Press this button, to turn on the I FEEL
function. When operating other function
and after signal was sent out, every 200ms
later, the I FEEL information will be sent
out. After I FEEL function turned on, in
every 10mins, the remote controller will
send the temperature information to main
controller. If repress this button, the I
FEEL function will be turned off.
7
1. Press SLEEP button, to set sleep.
2. Press TIMER ON and TIMER OFF button, can set the scheduled timer on
3. Press LIGHT button, to control the on and off of the displaying part of the
unit (This function may be not available for some units).
Operation of wireless remote control
Guide for operation- general operation
1. After powered on, press ON/OFF button, the unit will start to run.(Note: When
it is powered off, the guide louver of main unit will close automatically.)
2. Press MODE button, select desired running mode, or press COOL or HEAT
mode to enter into the corresponding operation directly.
3. Pressing +or - button, to set the desired temperature (It is unnecessary to
set the temp. at AUTO mode.)
4. Pressing FAN button, set fan speed, can select AUTO FAN, LOW, MID
and HIGH.
5. Pressing button, to select the swing.
Guide for operation- Optional operation
or timer off.
4. Press TURBO button, can realize the ON and OFF of TURBO
Introduction for special function
★
About blow function
This function indicates that moisture on evaporator of indoor unit will be blowed after the unit
is stopped to avoid mould.
1. Having set blow function on: After turning off the unit by pressing ON/OFF button
indoor fan will continue running for about 10 min. at low speed. In this period,
press blow button to stop indoor fan directly.
2. Having set blow function off: After turning off the unit by pressing ON/OFF button,
the complete unit will be off directly.
About AUTO RUN
★
When AUTO RUN mode is selected, the setting temperature will not be displayed on the
LCD, the unit will be in accordance with the room temp. automatically to select the suitable
running method and to make ambient comfortable.
About turbo function
★
If start this function, the unit will run at super-high fan speed to cool or heat quickly so that
the ambient temp. approachs the preset temp. as soon as possible.
function.
8
Operation of wireless remote control
About lock
★
Press +and - buttons simultaneously to lock or unlock the keyboard. If the remote controller
is locked, the icon
flicker for three times. If the keyboard is unlocked, the mark will disappear.
About swing up and down
★
1. Press swing up and down button continuously more than 2s,the main unit will swing back
and forth from up to down, and then loosen the button, the unit will stop swinging and present
position of guide louver will be kept immediately.
2. Under swing up and down mode, when the status is switched from off to , if press this
button again 2s later, status will switch to off status directly; if press this button again
within 2s,the change of swing status will also depend on the circulation sequence stated above.
About switch between Fahrenheit and Centigrade
★
Under status of unit off, press MODE and - buttons simultaneously to switc h
About new function of defrosting
★
It indicates: after starting this function by remote controller and the unit has been under
defrost status, If turn off the unit by remote controller, the unit will not stop defrosting until
it is finished; if change setting mode by remote controller, the function ,which is set last
time, won't be carried out until defrosting finished.
Operation of this function on or off: If remote controller is under off status, press mode button
and blow button simultaneously in order to enter or cancel this new function. If the unit is under
defrost mode, dual eight position on remote controller will display H1.If switch to heat mode,
the position will display H1, which flickers for 5s, in which case, press +/- button, H1 will
disappear and setting temp. be displayed.
After remote controller is powered on, the new defrost function will be defaulted to be closed.
will be displayed on it, in which case, press any button, the mark will
℃ and .
Changing batteries and notices
Slightly to press the place with , along the arrowhead direction to push the back cover of wireless
1.
remote control. (As show in figure)
2.
Take out the old batteries. (As show in figure)
3.
Insert two new AAA1.5V dry batteries, and pay attention to the polarity.
(As show in figure)
4.
Attach the back cover of wireless remote control. (As show in figure)
★
NOTE:
When changing the batteries, do not use the old or different batteries,
●
otherwise, it can cause the malfunction of the wireless remote control.
If the wireless remote control will not be used for a long time, please
●
take them out, and don't let the leakage liquid damage the wireless
remote control.
The operation should be in its receiving range.
●
It should be placed at where is 1m away from the TV set or stereo sound sets.
●
If the wireless remote control can not operate normally, please take them out,
●
after 30s later and reinsert, if they cannot normally run, please change them.
Sketch map for
changing batteries
9
Emergency Operation
Emergency Operation
When the wireless remote control is lost or damaged, please use the manual switch, at
this time, it is running in Auto Run mode that will not change the temperature setting
value and fan speed.
The manual switch can be operated as follow:
●
At operation: When the unit stopped running,
press ON/OFF button, unit will enter into AUTO
RUN mode. The microcomputer will accord to
the room temperature to select the (COOL,
HEAT, FAN) mode automatically, to obtain the
comfortable effect.
●
At stopping:When the unit is running, press the
ON/OFF button of the manual switch, the unit
will stop work.
The code switch can be operated as follow:
●
At operation: When the unit is stopped running,
adjust the code switch to AUTO, the unit will
enter into AUTO RUN mode. The microcomputer
will accord to the room temperature to select the
(COOL, HEAT, FAN) mode automatically, to
obtain the comfortable effect.
●
At stopping: When the unit is running, adjusts
the code switch to STOP position, the unit will
stop work.
AUTO/STOP
Manual Switch
Code Switch
10
Clean and care
CAUTION
●
●
Turn power off and pull out the power plug before cleaning air conditioner. Or it may
cause electric shock.
●●
Never sprinkle water on the indoor unit and the outdoor unit for cleaning because i
can cause an electric shock
●
Volatile liquid (e.g. thinner or gasoline) will damage the air conditioner. (So wipe th
units with a dry soft cloth, or a cloth slightly moistened with water or cleanser.
Clean the front panel(make sure to take it off before cleaning)
Take off the front panel
①
Along the direction of arrows to lift the front panel
up, meanwhile to hold both slots of the front panel
and take it out forcibly and then can take it off.
②
Washing
Clean with a soft brush, water and neutral detergent and then dry it.(Note: Before cleaning the
unit, please take down the displayer box firstly,
then to wash the panel, if the unit has displayer
on the front panel. Never use the water above
45
℃
to wash the panel, or it could cause
deformation or discoloration.)
.
t
e
)
Install front panel
③
Place two supporters of the front panel into the slots,
along the direction of arrows to cover and clasp the
front panel. As show in right figure.
Cleaning the air filters (Recommended once every three months)
Note: If dust is much more around the air conditioner, the air filters should be cleaned many
times. After taking off the filter, don't touch the fin of indoor unit, in order to avoid hurt your
fingers.
11
Clean and care
①
Take down the air filter
At the slot of surface panel to open an angle, pull the
air filter downward and take it out.
Cleaning
②
To clean the dust adhering to the filters, you can either
use a vacuum cleaner, or wash them with warm water
(the water with the neutral detergent should below 45
When the filters are very dirty (such as oil stain), and
dry it in the shade.
NOTE: Never use water above 45℃to wash, or it can
cause deformation or discoloration. Never partch it by
fire, or can cause a fire or deformation.
Reinsert the filters
③
Reinsert the filters along with the arrow head, then cover
the surface panel and clasp it.
Check before use
℃).
(a)
(b
)
Be sure that nothing obstructs the air outlet and intake
①
vents.
②
Check that whether ground wire is properly connected
or not.
Check that whether the batteries of air conditioner are
③
changed or not.
④
Check that whether the installation stand of the outdoor
unit is damaged or not. If damaged, please contact the dealer.
Maintain after use
Turn main power off.
①
Clean the filter and indoor and outdoor units' bodies.
②
③
Repaint the rubiginous place on the outdoor unit to prevent it from spreading.
12
Troubleshooting
Warning
Do not repair the air conditioner at your discretion. Incorrect repair may cause electric
shock or fire, so please contact Authorized Service Center for professional repair.
Following checks prior to contact may save your time and costs.
Phenomenon
Air conditioner does not run upon immediately
restart after a stop.
Wait
Air conditioner blows out bad smell when
it is initially started.
You may hear “Water Flowing” noise
when the air conditioner is running.
Sometimes a thin fog will flow out of the
outlet when air conditioner is running
under cooling mode.
Troubleshooting
●
To protect the air conditioner upon immediate
restart after a stop, the microcomputer
controller will delay the unit for 3 minutes
before the air conditioner will run.
●
The air conditioner itself has no bad smell.
If any. It is the bad smell accumulated from
environment. Solution: Clean the air filter.
If still any problem, the air conditioner shall
●
be cleaned (Please contact Authorized
Service Center).
●
When the air conditioner is started, or the
compressor is started or stopped during
running or the air conditioner is stopped,
sometimes you may hear “hua-hua” or “di-di-”
noise. This is the flowing sound of refrigerant
other than fault.
●
This might occur when indoor temperature
and humidity are high. This is because the
indoor air is quickly cooled down.
After a period of time, the fog will disappear
with the decrease of indoor temperature
and humidity.
You may hear a slight crack when the
air conditioner is started or stopped.
This is the sound of friction caused by
●
expansion of panel or other parts due
to the change of temperature.
13
Troubleshooting
Phenomenon
The unit can not run.
Break off
Cooling(Heating) efficiency is not good.
Wireless remote control is not available.
Troubleshooting
●
Has the power been shut down?
●
Does power plug come loose from the socket?
Is the circuit protection device tripped off or not?
●
●
Is voltage higher or lower?
(Tested by professionals)
●
Is the Timer correctly used?
●
Is Temp. setting suitable?
●
Were inlet and outlet vents obstructed?
●
Is there too much dusts accumulated and
obstructed the filter?
●
Are the windows and doors closed?
●
Did Fan speed set at low speed?
●
Is there any heat sources in the room?
●
The unit is interfered by abnormal or frequent
functions switchover occasionally the controller
cannot operate. At this time, you need to pull
out of the plug, and reinsert it.
●
Is it in its receiving range? Or obstructed?
To check the voltage in wireless remote control
inside is charged, otherwise to replace the
batteries.
●
Whether the wireless remote control is damaged.
If water leakage in the room.
If water leakage in outdoor unit.
Noise from indoor unit emitted.
●
The air humidity is on the high side.
●
Condensing water over flowed.
●
The connection position of indoor unit drainage
pipe is loosed.
●
When the unit is running in COOL mode, the
pipe and connection of pipe would be condensed
due to the water cooled down.
●
When the unit is running in Auto Defrosting mode,
the ice thawed and flowed out.
●
When the unit is running in HEAT mode, the
water adhered on heat exchanger dripped off.
●
The sound of fan or compressor relay is switching
on or off.
●
When the defrosting is started or stop running,
it will sound. That is due to the refrigerant flowed
to the reverse direction.
14
Troubleshooting
Phenomenon
Indoor unit cannot deliver air.
Moisture on air outlet vent.
Immediately stop all operations and plug out, contact
the dealer in following situations.
Troubleshooting
●
In HEAT mode, when the temperature of
indoor heat exchanger is very low, that
will stop deliver air in order to prevent cool
air. (Within 3min)
●
In HEAT mode, when the outdoor temperatur
is low or high humidity, there are much frost
be formed on the outdoor heat exchanger,
that the unit will automatically defrost, indoor
unit stop blowing air for 3-12mins.During the
defrosting, there is water flowing out or vapor
be produced.
●
In dehumidifying mode, sometimes indoor
fan will stop, in order to avoid condensing
water be vaporized again, restrain temper-
ature rising.
●
If unit is running under the high humidity for
a long time, the moisture will be condensed
on the air outlet grill and drip off.
e
There is harsh sound during operation.
The terrible odors emitted during operation.
Water is leaking in the room.
Air switch or protection switch often breaks.
Carelessy splash water or something into unit.
There is an abnormal heat in power supply cord
and power plug.
15
Stop running and pull out of the plug.
Installation service- Notices for installation
Important Notices
1. The unit installation work must be done by qualified personnel according to the local rules
and this manual.
2. If the air conditioner has not plug, directly connect it into the fixed circuit, a breaker should be
installed in the fixed circuit. all pole of this breaker should be switching off and the distance
of the contact should be at least 3mm.
Basic Requirements For Installation Position
Install in the following place may cause malfunction. If it is unavoidable contact with
service center please:
●
Place where strong heat sources, vapors, flammable gas or volatile object are emitted.
Place where high-frequency waves are generated by radio equipment, welders and
●
medical equipment.
●
Place where a lot of salinities such as coast exists.
Place where the oil (machine oil) is contained in the air.
●
Place where a sulfured gas such as the hot spring zones is generate
●
●
Other place with special circumstance.
Indoor Unit Installation Position Selection
1. The air inlet and outlet vent should be far from the obstruction, make sure that the air can
be blown through the whole room.
2. Select a position where the condensing water can be easily drained out, and the place is
easily connected for outdoor unit.
3. Select a location where the children can not reach.
4. Can select the place where is strong enough to withstand the full weight and vibration of
the unit. And will not increase the noise.
5. Be sure to leave enough space to allow access for routine maintenance. The height of the
installed location should be 230 cm or more from the floor.
6. Select a place about 1m or more away from TVset or any other electric appliances.
7. Select a place where the filter can be easily taken out.
8. Make sure that the indoor unit installation should accord with installation dimension
diagram requirements.
Outdoor Unit Installation Position Selection
1. Select a location from which noise and outflow air emitted by unit will not inconvenience
neighbors, animals, plants.
2. Select a location where there should be sufficient ventilation.
3. Select a location where there should be no obstructions cover the inlet and outlet vent.
4. The location should be able to withstand the full weight and vibration of the outdoor unit
and permit safe installation.
5. Select a dry place, but do not expose under the direct sunlight or strong wind.
6. Make sure that the outdoor unit installation dimension should accord with installation
dimension diagram, convenient for maintenance, repair.
7. The height difference of connecting the tubing within 5m, the length of connecting the
tubing within 10m.
8. Select a place where it is out of reach for the children.
9. Select a place where will not block the passage and do not influence the city appearance.
d.
16
Notices for installation
Safety Requirements For Electric Appliances
1. The power supply should be used the rated voltage and AC exclusive circuit, the power
cable diameter should be satisfied.
Don't drag the power cable emphatically.
2
It should be reliably earthed, and it should be connected to the special earth device,
3
the installation work should be operated by the professional.
The air switch must have the functions of magnetic tripping and heat tripping, in order
to protect the short circuit and overloading.
The min. distance from the unit and combustive surface is 1.5m.
4.
Note:
●
Make sure that the Live wire or Zero line as well as the earth wire in the family power
socket can not be wrong connected, there should be reliable and no short circuit in the
diagram.
●
wrong connection may cause fire.
Earthing requirements
1. Air conditioner is type I electric appliance, thus please do conduct reliable earthing
measure.
2. The yellow-green two-color wire in air conditioner is earthing wire and cannot be used
for other propose. It cannot be cut off and be fix it by screw, otherwise it would cause
electric shock.
3. The earth resistance should accord to the National Criterion.
4. The user power must offer the reliable earthing terminal. Please don't connect the
earthing wire with the following place:
① ② .
Tap water pipe.Gas pipe.
③
Contamination pipe.
④
Other places that professional personnel consider them unreliable.
Others
1.
The connection method of unit and power cable as well as the interconnect method
of each isolated component should refer to the circuit diagram stick on the unit.
The model of the blown fuse and rated value should refer to the silk-screen on the
2.
controller or fuse sleeve.
3. The appliance shall be installed in accordance with national wiring regulations.
4. This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning use of the appliance by a
person responsible for their safety.
5. Children should be supervised to ensure that they do not play with the appliance.
17
Installation dimension diagram
Install ation dime nsion diagram
Installationdimensiondiagram
Space to the ceiling
15
cm
Above
15cm
Above
Space to the wall
300
cm
Above
Air outlet side
2
230
cm
cm
Above
Space to the floor
15cm
Above
Space to the wall
Space to the obstruction
30cm
Above
Above
m
m
c
c
0
0
0
0
2
2
Air outlet side
18
Above
mc05
Air inlet side
Above
m
c
0
3
50cm
Above
Space to the wall
Install indoor unit
Install the rear panel
1.Always mount the rear panel horizontally. As the water drainage pipe at the left, when adjusting the rear
panel, this side should not be too high; the right side should be slightly high.
2. Fix the rear panel on the selected location
3. Be sure that the rear panel has been
fixed firmly enough to withstand the weight
of an adult of 60kg, furthermore, the weight
should be evenly shared by each screw.
Wall
Mark on the middle of it
Space to
the wall
150mm
above
Gradienter
Space to
the wall
150mm
above
Wall
Left
(Rear piping hole)
Fig.1
(Rear piping hole)
Right
Install the piping hole
1. Make the piping hole in the wall at a slight downward slant to the outdoor
side.
Wall pipe
2. Insert the piping-hole sleeve into the hole to prevent the connection
piping and wiring from being damaged when passing through the hole.
Indoor
Outdoor
Seal pad
Install the water drainage pipe
1. For well draining, the drain hose should be placed at a
downward slant.
2. Do not wrench or bend the drain hose or flood its end
by water
.
3. When the long drainage hose passing through indoor,
should wrap the insulation materials.
Connect indoor and outdoor electric wires
1. Open the front panel upwardly.
2.Screw off the fixing screw of cover plate and screw off cover plate.
3. Put the power connection cable through the back of indoor unit wire hole and take it out.
4. All the wiring should be connected according to the circuit diagram on the unit.
5. Put the power connection cable the section, which with sheath into wire groove, and
cover the cover plate, screw on the fixing screw, tighten the connection wire.
6. Cover the front panel cover.
7. For the cooling and heating unit, signal control wire can be passed through the connection
of connector and indoor unit, and use the wire clip that is under the body case, tighten the
signal control wire.
Wrenched
Bent
Flooded
19
Install indoor unit
NOTE:
When connecting the electric wire if the wire length is not enough, please contact with
the authorized service shop to buy a exclusive electric wire that is long enough and the
joint on the wire are not allowed.
●
The electric wiring must be correctly connected, wrong connection may cause spare parts
malfunction.
●
Tighten the terminal screw in order to prevent loose.
●
After tighten the screw, slightly pull the wire and confirm whether is it firm or not.
●
If the earth wire is wrong connection, that may cause electric shock.
●
The cover plate must be fixed, and tighten the connection wire, if it is poor installed, that
the dust, moisture may enter in or the connection terminal will be affected by outside force,
and will cause fire or elelctric shock.
Leakage circuit-breaker and air switch of correct capacity must be installed.
●
Install the indoor unit
●
The piping can be lead out from right, right rear,
left, left rear.
When routing the piping and wiring from the left
1.
or right side of indoor unit, cut off the tailings
from the chassis in necessary. (show in Fig.2)
(1)Cut off the tailings 1 when routing the wiring only.
(2)Cut off the tailings 1 and tailings 2 when routing
both the wiring and piping.(or 1,2,3)
Take out the piping from body case, wrap the piping
2.
electric wire, water pipe with tape and put them through the piping hole.(As show in Fig. 3)
Hang the mounting slots of the indoor unit on the
3.
upper tabs of the rear panel and check if it is firm
enough. (As show in Fig.4)
Fig.2
Right
Right rear
Tailing 3
Tailing 2
Tailing1
Fixing hook
Gas side piping
Finally wrap it
Mounting
board
Fig.4
External connection
Gas side piping
insulation
Water drainage pipe
with tape
Left
Left rear
electric wire
Fig.3
Liquid side
piping
Liquid side
piping
insulation
Mounting
board
Install the connection pipe
1.
Align the center of the piping flare with the
Screw in the flare nut by hand and then tighten the nut
2.
with spanner and torque wrench refer to the following.
Tightening torque table:
Hex nut diameter
Tightening torque
(N·m)
Ф6
Ф 9.52
Ф 12
15~20
31~35
50~55
relevant valve.
Indoor unit piping
Spanner
Taper nut Piping
Torque wrench
Ф 1660~65
Ф 1970~75
NOTE: Firstly connect the connection pipe to indoor unit, then to outdoor unit; pay attention
to the piping bending, do not damage the connection pipe; the joint nut couldn't tighten too
much, otherwise it may cause leakage.
20
Install outdoor unit
Electric Wiring
1. Disassemble handle of right side plate or front side plate of outdoor unit.
2. Take off wire clamp, connect and fix power connect cord to terminal of line bank.
Wiring should fit that of indoor
3. Fix the power connection cable with wire clamp, for cooling and heating unit, then use the
wire clamp to fix the signal control wire, then connect the corresponding connector.
4. Ensure if wire has been fixed well.
5. Install handle or front side plate.
NOTE:
●
Wrong wiring may cause
●
After the cable fixed, make sure
fixing place on the lead wire.
Air p u r ging a nd l e a kage t est
●
Air purging and leakage test
1. Connect charging hose of manifold valve to charge end of low
pressure valve (both high/low pressure valves must be tightly
shut).
2. Connect joint of charging hose to vacuum pump.
3. Fully open handle of Lo manifold valve.
4. Open the vacuum pump to evacuate. At the beginning, slightly
loosen joint nut of low pressure valve to check if there
is air coming inside. (If noise of vacuum pump has
been changed, the reading of multimeter is 0) Then
tighten the nut.
5. Keep evacuating for more than 15mins and make
sure the reading of multi-meter is
(-76cmHg).
6. Fully open high/low pressure valves.
7. Remove charging hose from charging end of low
pressure valve.
8. Tighten bonnet of low-pressure valve. (As shown in Fig.5)
unit.
spare parts malfunction.
there should be a free space
5
-1.0 10
pa
between the connection and
Liquid pipe
Gas pipe
Valve
cap
Vacuum pump
5
Fig.
Vacuum
gauge
21
Install outdoor unit
Leak hunting
●
Use soap water or leak hunting meter to check whether
the joints is leak.
Outdoor unit check point
Outdoor condensation drainage (Heat pump type only)
When the unit is heating, the condensing water
and defrosting water can be drained out reliably
through the drain hose.
Installation: Install the outdoor drain elbow in
25 hole on the base plate, and joint the
Ø
drain hose to the elbow, so that the wastewater
formed in the outdoor unit can be drained out
to a proper place.
Indoor unit check point
Fig.6
Chasis
Outdoor drain
elbow
22
Check after installation and test operation
Check after installation
Items to be checked
Has it been fixed firmly?
Have you done the refrigerant leakage test?
Is heat insulation sufficient?
Is water drainage well?
Is the voltage in accordance with the rated
voltage marked on the nameplate?
Is the electric wiring and piping
connection installed correctly and securely?
Has the unit been connected to a secure
earth connection?
Is the power cord specified?
Is the inlet and outlet been covered?
Has the length of connection pipes
and refrigerant capacity been recorded?
Possible malfunction
The unit may drop, shake or emit noise.
It may cause insufficient cooling(heating)
capacity.
It may cause condensation and dripping.
It may cause condensation and dripping.
It may cause electric malfunction
or damage the part..
It may cause electric malfunction
or damage the part.
It may cause electrical leakage.
It may cause electric malfunction
or damage the part
It may cause insufficient cooling(heating)
capacity.
The refrigerant capacity is not accurate.
Test Operation
1. Before test operation
(1) Do not switch on power before installation isfinished completely.
(2) Electric wiring must be connected correctly and securely.
(3) Cut-off valves of the connection pipes should be opened.
(4) All the impurities such as scraps and thrums must be cleared from the unit.
2. Test operation method
(1) Switch on power, press "ON/OFF" button on the wireless remote control to start the
operation.
(2) Press MODE button, to select the COOL, HEAT, FAN to check whether the operation
is normal or not.
23
Installation and Maintenance of Healthy Filter
Installation Instructions
1. Forcibly pull the panel for a specific angle
from the two ends of the front panel according
to the arrow direction. Then pull the air filter
downwards to remove it. (See Fig.a)
Fig. a
2. Mount the healthy filter onto the air filter,(as
shown in Fig.b). If the air filter cannot be installed, please mount the healthy filter on
Fig. b
Air filter
Healthy filter
the front case. (as shown in Fig.c).
Healthy filter
Fig. c
3. Mount the air filter properly along the arrow
direction in Fig.d, and then close the panel cover.
Fig. d
Cleaning and Maintenance
Take out the healthy filter before cleaning and reinstall it after cleaning
according to the installation instruction. Pay special attention to that silver
ion filter can't be cleaned with water, while active carbon, photocatalyst,
low temperature conversion (LTC) catalyst, formaldehyde eliminator, catechin or mite killing filter can, but can't with brush or hard things. Dry it in
the shade or sun after cleaning, but not by wiping.
Service Life
The healthy filter commonly has its usage lifetime for one year under
normal condition. As for silver ion filter, it is invalid when its surface becomes
black (green).
●
This supplementary instruction is provided for reference to the unit with
healthy filter. If the graphics provided herein is different from the physical