INVENTOR EVI-18, EVO-24, EVO-18, EVI- 24, APSI-24 Owner's Manual

...
Wall Mounted Unit
Owner’s Manual
Models
66129904458
Thank you for choosing INVENTOR air conditioning system. For correct use of this unit, please read this manual carefully and keep it for future reference.
EVI-18/ EVO-18 EVI-24 / EVO-24
CONTENTS
This symbol stands for the items should be forbidden.
This symbol stands for the items should be followed
..................................1
................................11
....................................14
..........................19
■ ...................................20
■ ..................................22
..................23
...............24
................................17
....................................12
Operation and maintenance
Notices for operation Notices for use
......................................3
Names and functions of each part
......................... 5
Operation of wireless remote control
........................6
Clean and care Troubleshooting
Installation service
Notices for installation Installation dimension diagram Install indoor unit Install outdoor unit Check after installation and test operation
Emergency operation
Installation and Maintenance of Healthy Filter
Do not dispose this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary.
Thank you for choosing INVENTOR air conditioner, please read this owner's manual
carefully before operating the unit and keep it carefully for consulation.
The products in this manual may be different with the real one, according to different models, some models have displayer and some models without displayer, the position and shape of the displayer please refer to the real one.
This appliance is not intended for use by persons (including children) with reduced
physiced, sensory or mental capabilities or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person reponsible for thei safety.
Children should be supervised to ensure that they do not play with the appliance.
Operation and maintenance-notices for operation
Be sure to pull out the power
Earth: The ground be connected!
If not, please ask the qualified person-
nel to install. Furthermore, don't conn-
ect each wire to the gas pipe, water pipe, drainage pipe or any other impr­oper places.
plug when not using the air co­nditioner for a long time.
Otherwise, the accumulated dust may cause fire or electric shock.
Select the most appropriate tem-
perature.
Keep room coo­er than outside about 5 degree.
It can preclude the electricity wasted.
Don't leave windows and doors open for a long time while operating the air conditioner.
It can decrease the air conditioning capacity.
Don't block the air intake or outlet vents of both the outdoor and indoor units.
It can decrease the air conditioning capacity or cause a malfunction.
Keep combustible spray away from the units more than 1m.
It can cause afire or explosion.
If it is damaged, it may lead to the fall of the unit and cause the injury.
Please note whether the installed stand is firm enough or not.
Don't step on the top of the outdoor unit or place something on it.
As falling off the outdoor unit can be dangerous.
Don't attempt to repair the air conditioner by yourself.
The wrong repair will lead to an electric shock or fire, so you should contact the service center to repair.
Notices for operation
If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a
similarly qualified person in order to avoid a hazard.
The airflow direction can be adjusted appro­priately. At operating, adjust the vertical airflow direction by adjusting the louvers of upward/do­wnward direction. And then, hold two ends of left and right louver to adjust the horizontal air­flow.
Louver of left/right directionLouver of upward/
downward direction.
Don't insert your hands or stick into the air intake or outlet vents.
Otherwise it will cause accident.
Don't blow the wind to animals and plants directly. It can cause a bad influence to them.
Don't apply the cold wind to the body for a long time.
It can cause the health problems.
Don't use the air conditioner for other purposes, such as drying clothes, preserving foods, etc.
Splashing water on the air conditioner can
cause an electric shock and malfunction.
Don't place a space heater near the air conditioner.
Or CO toxicosis may occur for imcomplete burning.
.
Anti-cool wind function:
In "Heat" mode, under the following three kinds of state, if indoor heat exchanger doesn't arrive at certain temp., indoor fan will not act, in order to prevent cool wind blowing(within 2 mins):
1. Heating starts. 2.After Auto Defrost finished. 3.Heating under the low temperature.
Gentle Breeze
In the following situation, the indoor unit may blow gentle breeze, and the guide louver rotate to a certain position:
1. In “Heat” mode, the unit turned on, the compressor doesn’t arrive the starting condition
2. In “Heat” mode, the temperature arrive at the setting value and the compressor stop running about 1min.
*
*
*
*
*
*
Notices for use
Working principle and special functions for cooling
Principle:
Anti-freezing function:
Working principle and special functions for heating
Principle:
Defrosting:
Air conditioner absorbs heat in the room and transmit to outdoor and discharged, so that indoorambient temperature decreased, its cooling capacity will increase or decrease by outdoor ambient temperature.
If the unit is running in COOL mode and in low termperature, there will be frost formed on the heat exchanger, when indoor heat exchanger temperature decreased below 0 , the indoor unit microcomputer will stop compressor running and protect the unit.
Air conditioner absorbs heat from outdoor and transmits to indoor, in this way to increase room temperature. This is the heat pump heating principle, its heating capacity will be
reduced due to outdoor temperature decrease. If outdoor temperature becomes very low, please operate with other heating equipments.
When outdoor temperature is low but high humidity, after a long while running, frost will form on outdoor unit, that will effect the heating effect, at this time, the auto defrosting
function will act, the heat running will stop for 8-10mins.
During the auto defrosting, the fan motors of indoor unit and outdoor unit will stop.
During the defrosting, the indoor indicator flashes, the outdoor unit may emit vapor. This is due to the defrosting, it isn't malfunction.
After defrosting finished,the heating will recover automatically.
3
4
Notices for use
The operating temperature range (outdoor temperature) for cooling unit is 21
~
43℃;
for cooling and heating unit is -5
~
43℃.
Working temperature range
Maximum cooling
Minimum cooling
Maximum heating
Minimum heating
Indoor sideDB/WB(oC)
Outdoor sideDB/WB(oC)
32/23 21/15
27/--­20/---
43/26
21/-
24/18
-5/-6
Names and functions of each part
Indoor unit
Air in
Air out
Air out
Outdoor unit
Wireless
remote control
Air in
Power cable Remote control
Front panel
Filter
Guide louver
Wall pipe Bind tape
Drainage pipe
Receive window
Heat
Cool
Power
Dry
ON/OFF
ON/OFF
5
SET TEMP/
AMBIENT TEMP
Names and functions of wireless remote control
ON/OFF button
ON/OFF
Remote control
Signal transmitter
AUTO COOL
DRY FAN
HEAT (only for cooling and heating unit)
Don't drop or throw the remote control; Don't let any liquid in the remote control and
Note: Be sure that there are no obstructions between receiver and remote controller;
Middle fan
put the remote control directly under the sunlight or any place where is very hot.
Press this button, Auto, Cool,Dry, Fan,
Heat mode can be selected circularly.
MODE button
MODE
Auto mode is default while power on. Under Auto mode,the temperature will not be displayed; Under Heat mode, the initial value is 28
;Under other
modes,
the initial value is 25
Press this button, Sleep On and Sleep Off can be selected. After powered on,Sleep
SLEEP button
SLEEP
Off is defaulted. After the unit is turned off, the Sleep function is canceled. After Sleep function set up, the signal of Sleep will display. In this mode, the time of timer can be adjusted. Under Fan and Auto modes, this function is not available.
Press this button, Auto, Low, Middle, High
speed can be circularly selected. After
FAN button
FAN
powered on,Auto fan speed is default. Under Dehumidify mode, Low fan speed only can be set up.
Low fan
High fan
Press this button, the clock can be set up,
signal blink and display.Within 5
CLOCK button
CLOCK
seconds, the value can be adjusted by pressing + or - button, if continuously press this button for 2 seconds above, in every 0.5 seconds, the value on ten place of Minute will be increased 1. During blinking, repress the Clock button, signal will be constantly displayed and it denotes the setting succeeded. After powered on, 12:00 is defaulted to display and signal will be displayed. If there is signal be
value is Clock value, otherwise is Timer value.
displayed that denotes the current time
Operation of wireless remote control
F)
82
F)
77
Press this button, the unit will be turned on, press it once more, the unit will be turned
off. When turning on or turning off the unit,
the Timer, Sleep function will be canceled, but the presetting time is still remained.
Press this button at unit On or Off status,
Light On and Light Off can be set up.
LIGHT button
LIGHT
After powered on, Light On is defaulted.
Remote control
BLOW button
BLOW
TURBO button
TURBO
+ button
+
Names and functions of wireless remote control
Operation of wireless remote control
Press this button, can turn on or turn off
the drying.In Cool and Dehumidifying mode,
this button,"BLOW" will be concealed, at this time the Blow function is turned off. After powered on, Blow OFF is defaulted.
When operating the ON/OFF button, or switching mode to Cool or Dehumidifying mode,the Blow function will keep the original status. If unit is turned off, Blow OFF only can be set up and send the signal. In Auto, Fan as well as Heat mode, Blow function can not be set up and there is no "BLOW" displaying.
press this button and will display "BLOW",
at this time the Blow is turned on. If repress
For presetting temperature increasing.
Press this button,can set up the temperature, when unit is on . Continuously
press and hold this button for more than 2 seconds, the corresponding contents will be
changed
rapidly, until unpress the button
℃(℉)
laying all along. In Auto mode, the temp­erature can not be set up, but operate this button can send the signal. Centigrade setting range :16-30; Fahrenheit scale setting range 61-86.
then send the information, is disp-
with multifunction; For some function, which the model dosen't have, if press the corresponding button on the remote controller that the unit will keep the original
running
status.
Notice: This is a general use remote controller, it could be used for the air conditioners
Press this button, could select displaying the indoor setting temperature or indoor ambient temperature.When the indoor unit firstly power on it will display the setting temperature, if the temperature's displaying
status is changed from other status to" ", displays the ambient temperature, 5s later or within 5s, it receives other remote control
signal that will return to display the setting temperature. if the users haven't set up the temperature displaying status,that will display the setting temperature.
After powered on, the setting temperature displaying is defaulted, (according to
customers requirements to display, if there is no requirement that will default to display the presetting temperature and there is no icon displayed on wireless remote control). Press this button, (When displaying ) , will display
presetting temperature; (when displaying ) will display indoor ambient temperature,
TEMP button
TEMP
current displaying status will not be
changed. If current displays indoor ambient temperature, if received the other remote control signal, it will display presetting temperature, 5s later, will back to display the ambient temperature.
(This function is applicable to partial of models)
(This function is applicable to partial of models)
In Cool or Heat mode, press this button can turn on or turn off the Turbo function. After turned on the Turbo function, its signal will be displayed. When switching the mode or changing fan speed, this
function will be canceled automatically.
Presetting temperature can be decreased.
Press this button, the temperature can be
- button
-
set up, continuously press this button and hold for two seconds, the relative contents can quickly change, until unhold
this button and send the order that the (oF)signal will be displayed all the time. The temperature adjustment is unav­ailable under the Auto mode, but the order can be sent by if pressing this button.
SWING UP AND DOWN BUTTON
TIMER ON
TIMER ON BUTTON
Timer On setting: Signal “ON” will blink and display, signal will conceal, the numerical section will become the timer on setting status. During 5 seconds blink, by pressing or button to adjust the time value of numerical section, every press of that button, the value will be increased or decreased 1 minute. Hold pressing or button, 2 seconds later, it quickly change, the way of change is: During the initial 2.5 seconds, ten numbers change in the one place of minute, then the one place is constant, ten numbers change in the tens place of minute at 2.5 seconds speed and carry. During 5s blink, press the Timer button, the timer setting succeeds. The Timer On has been set up, repress the timer On button, the Timer On will be canceled. Before setting the Timer, please adjust the Clock to the current actual time.
TIMER OFF BUTTON
Once press this key to enter into
TIMER OFF setup, in which case the TIMER OFF icon will blink. The method of setting is the same
TIMER OFF
as for TIMER ON.
Remote control
Names and functions of wireless remote control
Operation of wireless remote control
OFF
This is an universal use remote controller. If remote controller sends the following three kinds of status that the swing status of main
unit will be:
When the guide louver start to swing up and down, if turn off the Swing, the air guide louver will stop at current position.
which indicates the guide louver swings up and down between that all five positions.
with multifunction; For some function, which the model dosen't have, if press the corresponding button on the remote controller that the unit will keep the original
running status.
Notice: This is a general use remote controller, it could be used for the air conditioners
Press this button, to set up swing angle, which circularly changes as below:
This function indicates that moisture on evaporator of indoor unit will be blowed after the unit
About blow function
is stopped to avoid mould.
1. Having set blow function on: After turning off the unit by pressing ON/OFF button indoor fan will continue running for about 10 min. at low speed. In this period, press blow button
to stop indoor fan directly.
2. Having set blow function off: After turning off the unit by pressing ON/OFF button, the complete unit will be off directly.
Operation of wireless remote control
Introduction for special function
1. After powered on, press ON/OFF button, the unit will start to run.(Note: When it is powered off, the guide louver of main unit will close automatically.)
2. Press MODE button, select desired running mode, or press COOL or HEAT mode to enter into the corresponding operation directly.
3. Pressing +or - button, to set the desired temperature. (It is unnecessary
to set the temp. at AUTO mode.)
4. Pressing FAN button, set fan speed, can select AUTO FAN, LOW, MID
and HIGH.
5. Pressing button, to select the swing.
1. Press SLEEP button, to set sleep.
2. Press TIMER ON and TIMER OFF button, can set the scheduled timer on
3. Press LIGHT button, to control the on and off of the
displaying part of the
unit (This function may be not available for some units).
4. Press TURBO button, can realize the ON and OFF of TURBO
function.
or timer off.
Guide for operation- General operation
Guide for operation- Optional operation
When AUTO RUN mode is selected, the setting temperature will not be displayed on the LCD, the unit will be in accordance with the room temp. automatically to select the suitable
running method and to make ambient comfortable.
About turbo function
If start this function, the unit will run at super-high fan speed to cool or heat quickly so that the ambient temp. approachs the preset temp. as soon as possible.
About AUTO RUN
When the unit is running in Heat mode or Auto Heat mode, compressor and indoor fan is running, to turn the unit off, the compressor, outdoor fan will stop running. The upper and lower guide board
rotate to horizontal position, then the indoor fan will run at low fan speed, 10s later, the unit will turn off.
About Blow over heat (This function is applicable to partial of models)
1.
Changing batteries and notices
4.
2.
3.
Slightly to press the place with , along the arrowhead direction to push the back cover of wireless
remote control. (As show in figure) Take out the old batteries. (As show in figure) Insert two new AAA1.5V dry batteries, and pay attention to the polarity.
(As show in figure) Attach the back cover of wireless remote control. (As show in figure)
When changing the batteries, do not use the old or different batteries,
If the wireless remote control will not be used for a long time, please
otherwise, it can cause the malfunction of the wireless remote control.
take them out, and don't let the leakage liquid damage the wireless
remote control.
The operation should be in its receiving range. It should be placed at where is 1m away from the TV set or stereo sound sets. If the wireless remote control can not operate normally, please take them out,
after 30s later and reinsert, if they cannot normally
run, please change them.
Sketch map for changing batteries
NOTE:
Fig.1
Fig.2
About lock
About AUTO RUN
About new function of defrosting
will be displayed on it, in which case, press any button, the mark will
When AUTO RUN mode is selected, the setting temperature will not be displayed on the LCD, the unit will be in accordance with the room temp. automatically to select the suitable running method and to make ambient comfortable.
About turbo function
If start this function, the unit will run at super-high fan speed to cool or heat quickly so that the ambient temp. approachs the preset temp. as soon as possible.
Press +and - buttons simultaneously to lock or unlock the keyboard. If the remote controller is locked, the icon
flicker for three times. If the keyboard is unlocked, the mark will disappear.
About switch between Fahrenheit and Centigrade
Under status of unit off, press MODE and - buttons simultaneously to switch℃ and .
It indicates: after starting this function by remote controller and the unit has been under defrost status, If turn off the unit by remote controller, the unit will not stop defrosting until
it is finished; if change setting mode by remote controller, the function ,which is set last time, won't be carried out until defrosting finished
. Operation of this function on or off: If remote controller is under off status, press mode button and blow button simultaneously in order to enter or cancel this new function. If the unit is under
defrost mode, dual eight position on remote controller will display H1.If switch to heat mode, the position will display H1, which flickers for 5s, in which case, press +/- button, H1 will disappear and setting temp. be displayed.
After remote controller is powered on , the new defrost function will be defaulted to be closed.
Operation of remote control
10
If the wireless remote control is lost
or broken, please use the manual switch
Auto mode, but the temperature and fan
button. At this time, the unit will run at the
To open the panel, the manual switch
is on the displayer box.
It's a special selective buttonfor the users ,who are not accustomed to the
light at sleeping.
Get the displayer indicator light on: When setting the light function,the mark will
pressing this button. In which case,the diss- player indicator light will be on if the AC receives
Get the displayer indicator light off: If cancel the light function,the mark will disap-
per on the remote controller screen by pressing this
button. In which case, the displayer indicator light will
be off if the AC receives this signal.
Displayer indicator light control of indoor unit
display on the remote controller screen by
this signal.
Emergency operation
Emergency operation
speed cannot be changed. The operation was shown as below:
Turn on the unit: At unit turned off, press the button,the unit will run at Auto mode immediately.The microcomputer will accord
to the indoor temperature to select (Cooling, Heating, Fan) and obtain the comfortable effect.
Turn off the unit: At unit turned on, press the button, the unit will stop working.
Manual switch
Fig.3
11
Clean the air filter
(a)
(b)
Clean and care
Caution
Turn power off and pull out the power plug before cleaning air conditioner, or it may cause electric shock.
Never sprinkle water on the indoor unit and the outdoor unit for cleaning because it can cause an electric shock.
Volatile liquid (e.g. thinner or gasoline) will damage the air conditioner. (So wipe the units with a dry soft cloth, or a cloth slightly moistened with water or cleanser.)
Clean the front panel
Clean the air filter (Recommended once every three months)
NOTE: If dust is much more around the air conditioner, the air filters should be cleaned many times. After taking off the filter, don't touch the fin of indoor unit, in order to avoid hurt your fingers.
Take down the air filter
At the slot of surface panel to open an angle, pull the air filter
downward and take it out, please see the Fig. 4(a, b).
To clean the dust adhering to the filters, you can either use a vacuum cleaner, or wash them with warm water the water with the neutral detergent should below 45 degree) ,and dry it in the shade.
NOTE: Never use water above 45 to clean, or it can cause deformation or discoloration. Never parch it by fire, or can cause a fire or deformation.
Insert the air filter
Reinsert the filters along the direction of arrowhead, and then to cover the cover and clasp it.
Fig.4
When cleaning the front panel, please dip the cloth into the water temperature of 45 below, then to dry the cloth and wipe the dirty part.
Note: Please do not to immerse the front panel in water, due to there are microcomputer components and
circuit diagrams on the front panel.
12
Be sure that nothing obstructs the air outlet and intake vents.
Check that whether the batteries of air conditioner are
changed or not.
Check that whether the installation stand of the outdoor
unit is damaged or not. If damaged, please contact the dealer.
① ② ③
Clean and care
Check before use
Check that whether ground wire is properly connected or not.
Maintain after use
Turn main power off.
Clean the filter and indoor and outdoor units' bodies.
Clear dust and obstructions from the outdoor unit. Repaint the rubiginous place on the outdoor unit to prevent it from spreading.
Adopt the special shield to cover the outdoor unit, avoid the rain water, dust enter into the unit and get rust.
13
Once the air conditioner is stopped, it will not operate in approximately 3minutes to protect itself.
Troubleshooting
CAUTION
Don't attempt to repair the air conditioner by yourself, it can cause an electric shock or fire. Please check the following items before asking for repair, it can save your time and money.
Phenomenon
Troubleshooting
Not operate immediately when the air conditioner is restarted.
There's unusual smell blowing from the outlet after operation is started.
The unit has no peculiar smell by itself. If has, that is due to the smell accumulated in the ambient.
Solution method: Cleaning the filter. If problem still has, so need to clean air conditioner. (Please contact with the authorized maintenance center.)
Sound of water flow can be heard during the operation.
The air conditioner is started, when it is running the compressor started or stopped running, or the unit is stopped, sometimes there is swoosh or gurgle, the sound is due to refrigerant flowing they are not malfuncti­ons.
In COOL mode, sometimes the mist emitted from the air outlet vent.
When the indoor temperature and humidity are very high, this phenomenon would happen. This is caused by the room air is swiftly cooled down. After running for a while, indoor temperature and humidity will fall down, the mist will die away.
Creaking noise can be heard when start or stop the unit.
This is caused by the deformation of plastic due to the changes of temperature.
Waiting
14
Troubleshooting
Phenomenon
Troubleshooting
The unit can not run.
Has the power been shut down?
Is power plug loosed? Is the circuit protection device tripped off or not?
Is voltage higher or lower?
(Tested by professionals)
Is the TIMER correctly used?
Cooling(Heating) efficiency is not good.
Is Temp. setting suitable? Were inlet and outlet vents obstructed?
Is filter dirty? Are the windows and doors clothed? Did Fan speed set at low speed?
Is there any heat sources in the room?
Wireless remote control is not available.
The unit is interfered by abnormal or frequent functions switchover occasionally the controller cannot operate. At this time, you need to pull out of the plug, and reinsert it.
Is it in its receiving range? Or obstructed?
To check the voltage in wireless remote control inside
is charged, otherwise to replace the batteries.
Whether the wireless remote control is damaged.
If water leakage in the room. The air humidity is on the high side.
Condensing water over flowed.
The connection position of indoor unit drainage pipe is loosed.
If water leakage in outdoor unit. When the unit is running in COOL mode, the pipe
and connection of pipe would be condensed due
to the water cooled down.
When the unit is running in Auto Defrosting mode the ice thawed and flowed out.
When the unit is running in HEAT mode, the water adhered on heat exchanger dripped off.
Noise from indoor unit emitted. The sound of fan or compressor relay is switching
on or off.
When the defrosting is started or stop running, it will sound. That is due to the refrigerant flowed to the reverse direction.
Breaking off
15
Troubleshooting
Phenomenon
Troubleshooting
Indoor unit cannot deliver air.
Moisture on air outlet vent.
If unit is running under the high humidity for a long time, the moisture will be condensed on the air outlet grill and drip off.
Immediately stop all operations and plug out, contact the dealer in following situations.
There is harsh sound during operation. The terrible odors emitted during operation.
Water is leaking in the room. Air switch or protection switch often breaks.
Carelessy splash water or something into unit. There is an abnormal heat in power supply cord
and power plug.
Stop running and pull out of the plug.
In HEAT mode, when the temperature of indoor heat exchanger is very low, that will stop deliver air in order to prevent cool air. (Within 2min)
In HEAT mode, when the outdoor temperature is low or high humidity, there are much frost be formed on the outdoor heat exchanger, that the unit will automatically defrost, indoor unit stop blowing air for 3-12min. During the defrosting, there is water flowing out or vapor be produced.
In dehumidifying mode, sometimes indoor fan will stop, in order to avoid condensing water be vapo- rized again, restrain temperature rising.
16
17
1.
2.
Select a position where the condensing water can be easily drained out, and the place is easily connected for outdoor unit.
4.Can select the place where is strong enough to withstand the full weight and vibration o
f
the unit. And will not increase the noise.
5.
6.
7.
8.
Make sure that the indoor unit installation should accord with installation dimension
diagram requirements.
3.
Select a location where the children can not reach.
1.The unit installation work must be done by qualified personnel according to the local
rules and this manual.
2.Before installating, please contact with local authorized maintenance center, if unit is
not installed by the authorized maintenance center, the malfunction may not solved,
due to discommodious contacts.
3.W
4
.the appliance must be positioned so that the plug is accessible.
hen removing the unit to the other place, please firstly contact with the authorized
Maintenance Center in the local a
rea.
Notices for installation
Important Notices
Basic Requirements For Installation Position
Install in the following place may cause malfunction. If it is unavoidable contact with service center please:
Place where strong heat sources, vapors, flammable gas or volatile object are emitted.
Place where high-frequency waves are generated by radio equipment, welders and
medical equipment. Place where a lot of salinities such as coast exists. Place where the oil (machine oil) is contained in the air.
Place where a sulfured gas such as the hot spring zones is generated.
Other place with special circumstance.
Indoor Unit Installation Position Selection
The air inlet and outlet vent should be far from the obstruction, make sure that the air can be blown through the whole room.
Be sure to leave enough space to allow access for routine maintenance. The height of the installed location should be 250cm or more from the floor.
Select a place about 1m or more away from TVset or any other electric appliances.
Select a place where the filter can be easily taken out.
.Do not use the unit in the immediate surroundings of a laundry a bath a shower or a
swimming pool.
9
1
.
Select a location from which noise and outflow air emitted by unit will not inconvenience
neighbors, animals, plants.
2
.
Select a location where there should be sufficient ventilation.
3
.
Select a location where there should be no obstructions cover the inlet and outlet vent.
4
.
The location should be able to withstand the full weight and vibration of the outdoor unit
and permit safe installation.
5
.
Select a dry place, but do not expose under the direct sunlight or strong wind.
6
.
7.
8.
9.
Outdoor Unit Installation Position Selection
Make sure that the outdoor unit installation dimension should accord with installation
dimension diagram, convenient for maintenance, repair. The height difference of connecting the tubing within 5m, the length of connecting the tubing within 10m. Select a place where it is out of reach for the children.
Select a place where will not block the passage and do not influence the city appearance.
18
Note:
Make sure that the Live wire or Zero line as well as the earth wire in the family power socket can not be wrong connected, there should be reliable and no short circuit in the diagram.
wrong connection may cause fire.
4. The min. distance from the unit and combustive surface is 1.5m.
1. The power supply should be used the rated voltage and AC exclusive circuit,
the power cable diameter should be satisfied.
2. Don't drag the power cable emphatically.
3.
① ②
1. Air conditioner is type I electric appliance, thus please do conduct reliable earthing measure.
2. The yellow-green two-color wire in air conditioner is earthing wire and cannot be used
for other propose. It cannot be cut off and be fix it by screw, otherwise it would cause electric shock.
3. The earth resistance should accord to the National Criterion.
4. The user power must offer the reliable earthing terminal. Please don't connect the earthing wire with the following place:
Tap water pipe. Gas pipe.
Contamination pipe.
Other places that professional personnel consider them unreliable.
5. The appliance shall be installed in accordance with national wiring regulations. An all-pole disconnection switch having a contact separation of at least 3mm in all poles
should be connected in fixed wiring.
It should be reliably earthed, and it should be connected to the special earth device, the installation work should be operated by the professional.
The air switch must have the functions of magnetic tripping and heat tripping, in order
to protect the short circuit and overloading.
6.
5. The model and rating values for fuses according the silk print on fuse cover or related PCB board.
Notices for installation
Safety Requirements For Electric Appliances
Earthing requirements
1824K 25A
Air switch capacityAir-conditioner (W)
Space to the wall
Above
Above
Installation dimension diagram
Installation dimension diagram
Space to the ceiling
Space to the wall
Space to the wall
Air outlet side
Space to the floor
Above
Above
Above
Above
Above
Space to the obstruction
Air outlet side
Space to the wall
Air inlet side
Above
Above
Above
The dimensions of the space necessary for correct installation of the appliance including the minimum permissible distances to adjacent structures
19
20
Install indoor unit
1 5 0mm
φ 5 5mm
φ 5 5mm
1 5 0mm
Ø
5 5
Install the rear panel
1.Always mount the rear panel horizontally. Due to the water tray of indoor unit has been adopted the
both-way drainage design, the outlet of water tray should be adjusted slightly down when installing, that is taking the outlet of the water tray as the center of a circle, the included angle between the evaporator and level should be 0 or more, that is good for condensing water drainage.
2.Fix the rear panel on the wall with screws. (Where is pre-covered with plastic granula)
3.Be sure that the rear panel has been fixed
firmly enough to withstand the weight of an adult of 60kg, further more, the weight should be evenly shared by each screw.
Install the piping hole
1.Make the piping hole (Ф55) in the wall at a slight downward slant to the
outdoor side.
2.Insert the piping-hole sleeve into the hole to prevent the connection piping and wiring from being damaged when passing through the hole.
Install the water drainage pipe
1.For well draining, the drain hose should be placed at a downward slant.
2.Do not wrench or bend the drain hose or flood its end by water.
3.When the long drainage hose passing through indoor, should wrap the insulation materials.
Wrenched Bent
Flooded
Indoor Outdoor
Wall pipe
Seal pad
Fig.5
Wall
Wall
Mark on the middle of it
Gradienter
Left
Right
(Rear piping hole)
(Rear piping hole)
Space to the wall
above
Space to the wall
above
Connect indoor and outdoor electric wires
1.Open the surface panel.
2.Remove the wiring cover .
3.Route the power connection cord and signal control wire (for cooling and heating unit only) from the
4.Connect the interconnection cord to the terminal block, and then fix the cord with cord anchorge.
5.Reassemble the clampand wiring cover.
back of the indoor unit and pull it toward the front through the wiring hole for connection.
6.Recover the surface panel.
21
After tighten the screw, slight pull the wire and confirm whether is it firm or not.
The cover plate must be fixed, and tighten the connection wire, if it is poor installed, that
Install indoor unit
NOTE:
When connecting the electric wire if the wire length is not enough, please contact with
the authorized service shop to buy a exclusive electric wire that is long enough and the joint on the wire are not allowed.
The electric wiring must be correctly connected, wrong connection may cause spare parts malfunction.
Tighten the terminal screw in order to prevent loose.
If the earth wire is wrong connection, that may cause electric shock.
the dust, moisture may enter in or the connection terminal will be affected by outside force, and will cause fire or electric shock.
右后
4.
2.
3.
1.
⑴ ⑵
1.
2.
Install the indoor unit
The piping can be lead out from right, right rear, left
left rear.
When routing the piping and wiring from the left or right side of indoor unit, cut off the tailings from the chassis in necessary(Show in Fig.7)
Cut off the tailings 1 when routing the wiring only; Cut off the tailings 1 and tailings 2 when routing
both the wiring and piping. Take out the piping from body case, wrap the piping electric wire, water pipe with tape and pull them through the piping hole (As show in Fig.8)
Hange the mounting slots of the indoor unit on the upper tabs of the rear panel and check if it is firm
enough.(As show in Fig.9)
The height of the installed location should be 2. m
or more from the floor.
Install the connection pipe
Align the center of the piping flare with the relevant valve.
Screw in the flare nut by hand and then tighten the nut with spanner and torque wrench refer to the
following:
NOTE: Firstly connect the connection pipe to indoor unit, then to outdoor unit; pay attention to the piping bending, do not damage the connection
pipe; the joint nut couldn't tighten too
much, otherwise it may cause leakage.
Spanner
Torque wrench
Piping
Taper nut
Indoor unit piping
Fig.8
Mounting plate
Fixing hook
Mounting baord
Right
Right rear
Fig.7
Left rear
Left
Fig.6
Tailing 1
Tailing 2
Finally wrap it with tape
Gas side piping insulation
Water drainage pipe
Liquid side
Piping insulation
Gas side pipe
External connection
electric wire Liquid side piping
(N·m)
Ф6
Ф 9.52
Ф 12
31~35
15~20
50~55
Ф 16 60~65 Ф 19 70~75
Hex nut diameter
Tightening torque
5
Manifold Valve
Multimeter
-76cmHg
Lo Handle
Charging hose
Manometer
Hi handle
Charging hose
Vacuum pump
Low pressure valve
Ø
22
Air purging and leakage test
Condensate drainage of outdoor unit (no for cooling only)
The condensate and defrosting water formd during heating in the outdoor unit can be properly discharged by drainage pipe . Installation method:set the drain connection in 25 hole of the chassis has been installed and then connect drainage pipe with drain nozzle,so that condensate and defrosting waer can be properly discharged
Chassis Drain
connection
Install outdoor unit
Electric wiring
NOTE:
Wrong wiring may cause spare parts malfunction.
After the cable fixed, make sure there should be a free space between the connection and connection and fixing place on the lead wire.
3.
4.
5.
1.
2.
Disassemble the handle on the outdoor unit right side plate.
Take off cord anchorage. Connect and fix power connect cord (for cooling and heating unit,connect and fix power connect cord and signal control wire)to terminal block.
Fix the power connection cable with cord anchorage, (for cooling and heating unit, use the cord anchorage to fix the power connection cable and the signal control wire).
Ensure wire has been fixed well. Install the handle.
5
-1.0 10 pa
(-76cmHg)..
1. Connect charging hose of manifold valve to charge end of low pressure valve (both high/low pressure valves must be tightly shut).
2. Connect joint of charging hose to vacuum pump.
3. Fully open handle handle of Lo manifold valve.
4. Open the vacuum pump to evacuate. At the beginning, slightly
loosen joint nut of low pressure valve to check if there
is air coming inside. (If noise of vacuum pump has
been changed, the reading of multimeter is 0) Then tighten the nut.
5. Keep evacuating for more than 15mins and make sure the reading of multi-meter is
6. Fully open high/low pressure valves.
7. Remove charging hose from charging end of low pressure valve.
8. Tighten bonnet of low-pressure valve. (As shown in Fig.10)
Fig.9
3
yellow­green
yellow­green
blue
black
brown
blue
black
brown
Handle
3
power connect wire
wire clamp
3
INDOOR/OUTDOOR CONNECT FIG
INDOOR
OUTDOOR
power connect wire
1. (1)
Do not switch on power before installation isfinished completely.
(2)Electric wiring must be connected correctly and securely. (3)Cut-off valves of the connection pipes should be opened. (4)
2. (1)
Switch on power, press "ON/OFF" button on the wireless remote control to start
the operation.
(2)
Check after installation and test operation
Check after installation
Items to be checked Possible malfunction
Has it been fixed firmly?
The unit may drop, shake or emit noise.
Have you done the refrigerant leakage test?
It may cause insufficient cooling(heating) capacity
Is heat insulation sufficient?
It may cause condensation and dripping.
Is water drainage well?
It may cause condensation and dripping.
Is the voltage in accordance with the rated voltage marked on the nameplate?
It may cause electric malfunction or damage the part.
Is the electric wiring and piping connection installed correctly and securely?
It may cause electric malfunction
or damage the part. Has the unit been connected to a secure earth connection?
It may cause electrical leakage.
Is the power cord specified?
It may cause electric malfunction
or damage the part.
Is the inlet and outlet been covered? It may cause insufficient cooling(heating)
capacity.
Has the length of connection pipes and refrigerant capacity been recorded?
The refrigerant capacity is not accurate.
Test Operation
Before test operation
All the impurities such as scraps and thrums must be cleared from the unit.
Test operation method
Press MODE button, to select the COOL, HEAT (Cooling only unit is not available), FAN to check whether the operation is normal or not.
23
Fig. a
Installation Instructions
1. Forcibly pull the panel for a specific angle from the two ends of the front panel according to the arrow direction. Then pull the air filter
2. Mount the healthy filter onto the air filter,(as shown in Fig.b). If the air filter cannot be in­stalled, please mount the healthy filter on
3. Mount the air filter properly along the arrow direction in Fig.d, and then close the panel cover.
ion filter can't be cleaned with water, while active carbon, photocatalyst, low temperature conversion (LTC) catalyst, formaldehyde eliminator, ca-
The healthy filter commonly has its usage lifetime for one year under
normal condition. As for silver ion filter, it is invalid when its surface becomes
according to the installation instruction. Pay special attention to that silver
Take out the healthy filter before cleaning and reinstall it after cleaning
Installation and Maintenance of Healthy Filter
Cleaning and Maintenance
Service Life
Healthy filter
Air filter
Healthy filter
downwards to remove it. (See Fig.a)
the front case. (as shown in Fig.c)
Fig. b
Fig. c
Fig. d
techin or mite killing filter can, but can't with brush or hard things. Dry it in the shade or sun after cleaning, but not by wiping.
black (green).
goods, the latter one shall prevail. The quantity of healthy filters shall be based on the actual delivery.
This supplementary instruction is provided for reference to the unit with
healthy filter. If the graphics provided herein is different from the physical
24
Loading...