Invacare Alegio NG User guide

Invacare®Alegio™NG
enBed
UserManual
ThismanualMUSTbegiventotheuseroftheproduct. BEFOREusingthisproduct,thismanualMUSTbereadandsaved forfuturereference.
©2023InvacareCorporation Allrightsreserved.Republication,duplicationormodicationinwholeorinpartisprohibitedwithoutpriorwritten permissionfromInvacare.Trademarksareidentiedby™and®.AlltrademarksareownedbyorlicensedtoInvacare Corporationoritssubsidiariesunlessotherwisenoted.
Contents
1General.........................................4
1.1Introduction..................................4
1.1.1SymbolsinthisDocument.....................4
1.2IntendedUse.................................4
1.2.1IntendedOperator...........................4
1.3ServiceLife...................................5
1.4Compliance...................................5
1.4.1Product-specicstandards.....................5
1.5WarrantyInformation...........................5
1.6LimitationofLiability............................5
2Safety..........................................6
2.1Generalsafetyinformation.......................6
2.2Mattresses...................................7
2.3Safetyinformationonelectromagneticinterference.....7
2.4Labelsandsymbolsontheproduct.................8
2.4.1Identicationlabel...........................8
2.4.2OtherLabels...............................8
3Setup...........................................10
3.1GeneralSafetyInformation.......................10
3.2Mainpartsofthebed...........................10
3.3Assemblyofthebed............................10
3.4ControlBox...................................11
3.5Wiring......................................12
3.6Installingbedends.............................12
3.6.1Bedendbrackets............................12
3.6.2BedendswithU-bracketstyletting.............13
3.6.3BedendswithSannestyletting................13
3.6.4SabrineandCamilabedends...................13
3.7Installingsiderails..............................13
3.7.1VersoIIsiderail.............................13
3.7.2Scala2siderail.............................14
3.7.3BrittVandLinesiderail......................14
3.7.4Lisasiderail................................15
3.8Installingthemattresssupportextension.............16
3.9InstallRastox.................................16
3.10Dismantlethebed.............................16
4Operatingthebed.................................18
4.1GeneralSafetyInformation.......................18
4.1.1Mattressretainers...........................18
4.2Handcontrol.................................18
4.3Lockingfunction...............................18
4.4Operatingsiderails.............................18
4.4.1VersoIIsiderails............................19
4.4.2OperatingScala2siderail.....................19
4.4.3BrittVandLinesiderails......................19
4.4.4Lisasiderail................................20
4.5Castorsandbrakes.............................20
4.5.1Castorbrake...............................20
4.5.2Centralbrakesystem.........................20
4.6Liftingpole...................................20
4.6.1Placetheliftingpole.........................20
4.6.2Adjustingthehandleheight....................21
4.7Adjustingthelegsection.........................21
4.8Emergencypositions............................21
4.8.1Emergencyreleaseofamattresssupportsection....21
4.9TransportationandStorage.......................21
5Options.........................................22
5.1Listofavailableoptions..........................22
5.2Transporttrolley...............................22
6Maintenance.....................................25
6.1Generalmaintenanceinformation..................25
6.2Dailyinspections...............................25
6.3Generalservicinginformation.....................25
6.4Checklist-Maintenance.........................25
6.5Inspectionafterrelocation-Preparefornewuser......25
6.6Checklist-Afterrelocation.......................25
6.7CleaningandDisinfection........................26
6.7.1Generalsafetyinformation.....................26
6.7.2CleaningIntervals............................26
6.7.3CleaningbyHand............................26
6.7.4DisinfectionInstructions.......................26
6.8Lubrication...................................26
7AfterUse........................................27
7.1Disposal.....................................27
7.2Reconditioning................................27
8Troubleshooting...................................28
8.1Troubleshootingelectricalsystem...................28
9T echnicalData....................................29
9.1Materials....................................29
9.2Dimensions...................................29
9.3Weights.....................................29
9.4MattressDimensions............................29
9.5SideRails....................................30
9.6Environmentalconditions........................30
9.7Electricalsystem...............................30
10Electromagneticcompatibility(EMC)..................31
10.1GeneralEMCinformation.......................31
10.2Electromagneticemission........................31
10.3ElectromagneticImmunity.......................31
10.3.1TestspecicationsforimmunitytoRFwireless
communicationsequipment...................32
Invacare®Alegio™NG
UKR P

1General

1.1Introduction

Thisusermanualcontainsimportantinformationaboutthe handlingoftheproduct.Toensuresafetywhenusingthe product,readtheusermanualcarefullyandfollowthe safetyinstructions.
Onlyusethisproductifyouhavereadandunderstood thismanual.Seekadditionaladvicefromahealthcare professionalwhoisfamiliarwithyourmedicalconditionand clarifyanyquestionsregardingthecorrectuseandnecessary adjustmentwiththehealthcareprofessional.
Notethattheremaybesectionsinthisdocument,whichare notrelevanttoyourproduct,sincethisdocumentapplies toallavailablemodels(onthedateofprinting).Ifnot otherwisestated,eachsectioninthisdocumentreferstoall modelsoftheproduct.
Themodelsandcongurationsavailableinyourcountrycan befoundinthecountry-specicsalesdocuments.
Invacarereservestherighttoalterproductspecications withoutfurthernotice.
Beforereadingthisdocument,makesureyouhavethe latestversion.Y oundthelatestversionasaPDFonthe Invacarewebsite.
Ifyoundthatthefontsizeintheprinteddocumentis difculttoread,youcandownloadthePDFversionfromthe website.ThePDFcanthenbescaledonscreentoafont sizethatismorecomfortableforyou.
Formoreinformationabouttheproduct,forexampleproduct safetynoticesandproductrecalls,contactyourInvacare distributor .Seeaddressesattheendofthisdocument.
Incaseofaseriousincidentwiththeproduct,youshould informthemanufacturerandthecompetentauthorityin yourcountry.

1.1.1SymbolsinthisDocument

Symbolsandsignalwordsareusedinthisdocumentand applytohazardsorunsafepracticeswhichcouldresultin personalinjuryorpropertydamage.Seetheinformation belowfordenitionsofthesignalwords.
WARNING Indicatesahazardoussituationthatcouldresult inseriousinjuryordeathifitisnotavoided.
CAUTION Indicatesahazardoussituationthatcouldresult inminororslightinjuryifitisnotavoided.
NOTICE Indicatesahazardoussituationthatcouldresult indamagetopropertyifitisnotavoided.
TipsandRecommendations Givesusefultips,recommendationsand informationforefcient,trouble-freeuse.
OtherSymbols
(Notapplicableforallmanuals)
UKResponsiblePerson Indicatesifaproductisnotmanufacturedin theUK.
Triman Indicatesrecyclingandsortingrules(only relevantforFrance).

1.2IntendedUse

Themedicalbediselectricallyoperated,adjustableinheight andfeaturesaprolingsupportsurfaceintendedtobeused incombinationwithamattress.Medicalbedsaredesigned forsupportofthepatientandusedforthemitigation, relief,andrecoveryfromcertainmedicalconditions.The medicalbedalsosupportsandeasesthecaregivers’working environment.
TheMedicalbedisintendedtobeusedon:
Applicationenvironment3;Long-termcareina medicalareawheremedicalsupervisionisrequired andmonitoringisprovidedifnecessaryandmedical electricalequipmentusedinmedicalproceduresmay beprovidedtohelpmaintainorimprovethecondition ofthepatient.
Applicationenvironment4;Careprovidedinadomestic areawheremedicalelectricalequipmentisusedto alleviateorcompensateforaninjury,disabilityor disease.
IntendedUsers
Apersonwithamedicalconditionthatneedstobecared forinbed.
Indications
Thebedisintendedforadultusers,havingaphysicalsize equaltoormorethan146cm,aweightequaltoormore than40kgandabodymassindex(BMI)equaltoormore than17.
Thebedisintendedforindooruseonly .
Maximumuserweightis135kgandsafeworkingloadis 170kg.
Contra-indications
Thebedisnotintendedfortransportationofusers.Itis mobilewithinaroomwithauserinit.Castorsarelockable.
Thebedisnotintendedforpersonswithapsychosocial disability.
WARNING!
Anyotherorincorrectusecouldleadtohazardous situations. Invacareacceptsnoliabilityforanyuse,change orassemblyoftheproduct,otherthanstatedin thisusermanual.

1.2.1IntendedOperator

Ahealthcareprofessionalorprivatepersonwhohasreceived propertrainingistheintendedoperatorofthisproduct.
Thehandcontrolcanalsobeoperatedbytheoccupantof thebed.
4
1563578-H
General

1.3ServiceLife

Theexpectedservicelifeofthisproductisveyearswhen useddailyandinaccordancewiththesafetyinstructions, maintenanceintervalsandcorrectuse,statedinthismanual. Theeffectiveservicelifecanvaryaccordingtofrequencyand intensityofuse.

1.4Compliance

Qualityisfundamentaltothecompany’soperation,working withinthedisciplinesofISO13485.
ThisproductfeaturestheCEmark,incompliancewiththe MedicalDeviceRegulation2017/745ClassI.
ThisproductfeaturestheUKCAmark,incompliancewith PartIIUKMDR2002(asamended)ClassI.
Wearecontinuouslyworkingtowardsensuringthatthe company’simpactontheenvironment,locallyandglobally, isreducedtoaminimum.
WeonlyuseREACHcompliantmaterialsandcomponents.
WecomplywiththecurrentenvironmentallegislationsWEEE andRoHS.
Forfurtherinformationaboutlocalstandardsandregulations, contactyourlocalInvacarerepresentative.Seeaddresses attheendofthisdocument.

1.5WarrantyInformation

Weprovideamanufacturer’swarrantyfortheproduct inaccordancewithourGeneralTermsandConditionsof Businessintherespectivecountries.
Warrantyclaimscanonlybemadethroughtheprovider fromwhomtheproductwasobtained.

1.6LimitationofLiability

Invacareacceptsnoliabilityfordamagearisingfrom:
Non-compliancewiththeusermanual
Incorrectuse
Naturalwearandtear
Incorrectassemblyorset-upbythepurchaserorathird party
T echnicalmodications
Unauthorisedmodicationsand/oruseofunsuitable spareparts
1.4.1Product-specicstandards
TheproducthasbeentestedandconformstoIEC60601-2-52 (Particularrequirementsforthebasicsafetyandessential performanceofmedicalbeds)andallrelatedstandards.
1563578-H5
Invacare®Alegio™NG

2Safety

2.1Generalsafetyinformation

Thissectionofthemanualcontainsgeneralsafety informationaboutyourproduct.Forspecicsafety information,refertotheappropriatesectionofthemanual andprocedureswithinthatsection.
WARNING! Riskofinjuryordamage
–Donotusethisproductoranyavailableoptional
equipmentwithoutrstcompletelyreading andunderstandingtheseinstructionsandany additionalinstructionalmaterialsuchasuser manualsorinstructionsheetssuppliedwith thisproductoroptionalequipment.Ifyouare unabletounderstandthewarnings,cautionsor instructions,contactahealthcareprofessional, Invacareproviderorqualiedtechnicianbefore attemptingtousethisproduct.
–Donotmakeanyunauthorizedalterationsor
modicationstotheproduct.
WARNING! Riskofentrapment/suffocation
There’sariskofentrapment/suffocation betweenmattresssupport,siderailandbedend orbetweenmovingpartsandobjectsplaced nearbythebed.
–Thebedmustnotbeusedbypersonsunder12
yearsofage,orbypersonswithabodysize equivalenttoanaverage12yearsoldorsmaller .
–Thebed,incombinationwithsiderailsmust
notbeusedbypersonshavingaphysicalsize lessthan146cm,aweightlessthan40kgora bodymassindex(BMI)lessthan17.
–Duetomattresscompression,anincreased
riskmayoccurovertime.Periodicallymonitor gapsbetweenthebed,mattressand/orside rail.Replacemattressifthegapsmayleadto entrapment.
WARNING! Riskofslippingthroughtheopenings
Thebedfullsallrequirementsregarding maximumdistances.However,itispossible thatpersonswithsmallbodydimensionsslip throughtheopeningsbetweenthesiderailsor throughtheopeningbetweenthesiderailand themattresssupport.
–Payspecialattention,ifthebedisusedforthe
careofpersonswithsmallbodydimensions.
WARNING! Riskofinjuryordamage
Inappropriatehandlingofcables,incorrect connectionsanduseofunauthorizedequipment cancauseelectricalshockandproductfailure.
–Donotkink,shearorotherwisedamagethe
cablesoftheproduct.
–Makesurethatnocablesarejammedor
damaged,whentheproductisused.
–Disconnecttheplugfromthemainsbefore
movingthebed.
–Makesurethewiringiscorrectandconnections
areproper.
–Donotuseunauthorizedequipment.
WARNING! Riskoftripping,entanglementorstrangulation
Improperroutingofcablesmaycausetripping, entanglementorstrangulationhazard.
–Ensureallcablesareroutedandsecured
properly.
–Ensuretherearenoloopsofexcesscable
extendingawayfromtheproduct.
WARNING! Riskofinjuryordamage
Ignitionsourcescancauseburnsorre.
–Bedmustbeplacedwithasafetyspacefrom
possibleignitionsources(heater ,replace,etc.)
–Thepatientandassistantsmustnotsmoke
whileusingoroperatingthebed.
WARNING! Riskofinjuryordamage
Toavoidinjuryordamagewhenoperatingthe product:
–Closesupervisionisnecessarywhentheproduct
isusednearchildrenorpets.
–Donotletchildrenplaywiththeproduct.
CAUTION!
–Forapersonenteringorexitingthebed,always
lowerthebedtoanappropriateheight.For enteringorexitingthebed,thebackrestsection ofthemattresssupportcanbeusedasan assistance.Makesurethepatientislaiddown atthecentreofthebackrestsection.When thebackrestsectionisbeingraisedtheallowed maximumweightforthebackrestsectionis 45%ofmaximumsafeworkingload.
–Alwayslowerthebedtothelowestposition
beforeleavingapersoninthebedunattended.
–Makesurethatthereisnothingunder ,over ,
ornearthebedthatcanobstructtheheight adjustment,likeforexamplefurniture,liftsor windowframes.
61563578-H
CAUTION!
A
Non-originalorwrongaccessoriesmayaffectthe functionandsafetyoftheproduct.
–Onlyuseoriginalaccessoriesfortheproduct
inuse.
–Duetoregionaldifferences,refertoyour
localInvacarecatalogorwebsiteforavailable accessoriesorcontactyourlocalInvacare representative.Seeaddressesattheendof thisdocument.
CAUTION! Riskofinjuryordamage
Theproductcangethotwhenexposedtosunlight orotherheatsources.
–Donotexposetheproducttodirectsunlightfor
prolongedperiods.
–Keeptheproductawayfromheatsources.
WARNING! Riskoffalling
Theusercanfallovertheedgeandgetseriously injured,iftheverticaldistanceAbetweenthe topofthemattressandtheedgeoftheside rail/bedend,istooshort.Seeimageabove.
–AlwayskeepaminimumdistanceAof22cm. –Followthemaximummattressheightin
combinationwiththesiderailasstatedinthe mattresstableinchapter9T echnicalData,
page29
.
Safety

2.2Mattresses

CAUTION!
Thereisariskofentrapmentofngersinthe bedmovingparts.
–Payattentiontoyourngers.
NOTICE!
Thebedhasnoisolator(mainswitch).Ifthebed needstobeelectricallydisconnected,ithastobe unpluggedfromthemainssocket.
–Alwaysplacethebedinawaysothemains
socketiseasilyaccessibletounplugthebed.
NOTICE!
Accumulationoflint,dustandotherdirtcan impairtheproduct.
–Keeptheproductclean.
WARNING! Safetyaspectsregardingcombinationofside railsandmattresses:
Togetthehighestpossiblesafetylevel,when usingsiderailsonthebed,theminimumand maximummeasuresformattresses,mustbe respected.
–Forcorrectmattressmeasuresseemattress
tableinchapter9TechnicalData,page29.

2.3Safetyinformationon electromagneticinterference

WARNING! Riskofmalfunctionduetoelectromagnetic interference
Electromagneticinterferencebetweenthis productandotherelectricalequipmentcanoccur anddisturbtheelectricaladjustmentfunctions ofthisproduct.Toprevent,reduceoreliminate suchelectromagneticinterference:
–Onlyuseoriginalcables,accessoriesandspare
parts,tonotincreaseelectromagneticemission orreduceelectromagneticimmunityofthis product.
–Donotuseportableradiofrequency(RF)
communicationsequipmentcloserthan30cm toanypartofthisproduct(includingcables).
–Donotusethisproductnearactive
high-frequencysurgicalequipmentandthe RFshieldedroomofasystemformagnetic resonanceimaging,wheretheintensityof electromagneticdisturbancesishigh.
–Ifdisturbancesoccur,increasethedistance
betweenthisproductandtheotherequipment orswitchitoff.
–Refertothedetailedinformationandfollow
theguidanceinchapter10Electromagnetic
compatibility(EMC),page31
.
WARNING! Riskofentrapmentand/orsuffocation
–Theusercouldgettrappedand/orsuffocate,if
thehorizontalspace,betweenthemattressside andtheinsideofthesiderail,istoobig.Follow theminimumwidth(andlength)ofmattresses incombinationwithasiderail,asstatedin themattresstableinchapter9T echnicalData, page29.
–Beawarethatusingverythickorsoft
mattresses(lowdensity),oracombinationof these,increasestherisk.
1563578-H
7
Invacare®Alegio™NG
YYYY-MM
Invacare Portugal, Lda Rua Estrada Velha 949 4465-784 Leça do Balio, Portugal
XXXXXXXXXXXXX
SN
= xxx kg
XXXXXXXXXXXXX
XXX XXX XX XX XX X XXX XXX XX XX XX X XXX XXX XX XX XX X XXX XXX XX XX XX X XXX XXX XX XX XX X
XX
XX
XX
XX
XX
XX
XXX
XXX
= XXX
WARNING! Riskofmalfunctionduetoelectromagnetic interference
Donotusethisbedadjacenttoorstackedwith otherelectricalequipment,thanspeciedinthe following,asitcouldresultinimproperoperation. Ifsuchuseisnecessary,thebedandtheother equipmentmustbecloselyobservedtoverify thattheyareoperatingnormally. ThisbedcanbeusedtogetherwithInvacare approvedaccessoriesandmedicalelectrical equipmentconnectedtotheheart(intracardially) orbloodvessels(intravascularly)providedthat followingpointsarerespected:
–Medicalelectricalequipmentshouldnotbe
xedonthebed’smetallicaccessoriessuchas siderails,liftingpole,driprod,bedends,etc.
–Themedicalelectricalequipmentpowersupply
cordshouldbekeptclearoftheaccessoriesor anyothermovingpartsofthebed.
TypeBappliedpart
WEEEconform
EuropeanConformity
UKConformityAssessed
Abbreviationsfortechnicaldata:
Iin=IncomingCurrent
Uin=IncomingVoltage
Int.=Intermittence
AC=AlternatingCurrent
Max=maximum
min=minutes
Formoreinformationabouttechnicaldata,referto9 TechnicalData,page29.

2.4Labelsandsymbolsontheproduct

2.4.1Identicationlabel
Theidenticationlabelisplacedontheframeofthebedand containsthemainproductinformation,includingtechnical data.
Serialnumber
Referencenumber
Manufacturer
Dateofmanufacture

2.4.2OtherLabels

Readtheusermanualbeforeusingthisproductandfollow allinstructionsforsafetyanduse.
Denitionofmin.weight,min.heightand min.bodymassindexofanadultuser .
SeeIntendedUse.
Refertouserdocumentationforthe correctmattressmeasures.
See9TechnicalData,page29.
Totalweightoftheproductwiththe
Medicaldevice
maximumsafeworkingloadapplied
Temperaturelimit
Max.userweight
Humiditylimitation
Max.safeworkingload
Atmosphericpressurelimitation
CLASSIIequipment
81563578-H
Safety
< 6 cm
Transportandstorageconditions
Operationconditions
Marksoutthelocationofconnectionformeansof potentialequalization.
(Notpresentonallversionsofthisproduct)
Labelon3/4lengthsiderails
Indicatesthemaximumspacebetweensiderailandthe headbedend.
Seethemountinginstructioninthismanualorthe instructiondeliveredwiththesiderail.
1563578-H9
Invacare®Alegio™NG

3Setup

3.1GeneralSafetyInformation

WARNING! Riskofinjuryordamage
Damagedpartsmayaffectthesafetyofthe product.
–Checkallpartsforshippingdamagebeforeuse. –Incaseofdamage,donotusetheproduct
andcontactyourInvacareproviderforfurther instructions.
Mattresssupport,headsection
A
Mattressretainers,4pcs
B
Motor,mattresssupportbackrestsection
C
D
Mattresssupport,thigh/legsection
Liftmotor
E
Castor,4pcs
F
ControlBox
G
Sheararms
H
Mattresssupportframe
I
Handcontrol(notshowninimage)
WARNING! Riskofinjuryordamagetoproperty
Theassemblyofthebedandinstallationof accessoriesmustonlybeperformedbyaqualied technicianorapersonwhohasreceivedproper training.
–Followinstructionscarefully.Ifyouhaveany
questionregardingtheassembly,contactyour Invacareprovider .
–Theelectricalequipmentofthebedmustnot
bedismantledorcombinedwithotherelectrical equipment.
–Aftereachassembly,checkthatallttingsare
properlytightenedandthatallpartshavethe correctfunction.
NOTICE!
–T opreventcondensation,thebedshould
notbeuseduntilithasreachedoperating temperature.See9T echnicalData,page29

3.2Mainpartsofthebed

Siderailsandbedendsarenotdeliveredinthe standardconguration.Formoreinformationabout siderails,bedendsandotheraccessories,contact yourInvacarerepresentative.
WARNING! Riskofinjury
Theusercanfallovertheedgeandgetseriously injuredifthebedisusedwithoutbedendsand siderails

3.3Assemblyofthebed

Mattresssupport
1.
Placebaseandsheararmassemblyontheoorand lockallcastors.
2.
a.Placethemattresssupportfootsectionattheendof
thebedwhichhastheliftingactuator .
b.AligntheplasticsnaplockttingsAonthemattress
supportwiththepivotpinsBonthesheararm.
c.PressdownrmlytoengagethepivotpinsBinthe
snaplockttingA.RotatethelockingpinConthe snaplockttingtopreventdisengagementofthe footsection.
101563578-H
Setup
B
A
C
D
E
F
G
3.
a.Placetheheadsectiononthesheararmsatthe
oppositeendofthebed.
b.Alignthesquareplasticguideswiththechannelon
theheadsection.
c.Liftthelowerendofthefootsectiontoalignthe
bracketswiththeframetubesoftheheadsection.
4.
8.
Attachthecablettingtotheholeofthedeckbracket withtheclevispinprovidedandmakesuretheheadof theclevispinisonthesamesideastherastoxdeck brackets.
9.
a.Pushthefootsectiontowardstheheadsectionuntil
theframetubesaretouching.
b.Securetheheadandfootsectiononeachsidewith
thengerscrewA.
Ifthebedisprovidedwithawireactuatedfoot section,followsteps5–10.
5.Unfastenthecablefromtheheadsection.
6.
Fixtheclevispinwiththehitchpin.
10.Lowerthekneepivotpointandensurethecableand pinaremountedproperly.

3.4ControlBox

Thecontrolboxislatchedtotheliftmotor.
Liftthefootsectionandlaycableovertubeandguide pulley.
7.Lowerthefootsectionandraisethekneepivotpoint.
1563578-H
ThecontrolboxAisprovidedwithalabelwithsymbols showingwheretoconnectthemotorplugs:
Thighsection’smotorB.
LiftmotorC.
BackrestmotorD.
HandcontrolE.
notusedF.
ThecontrolboxisequippedwithagreenLEDG whichindicatesitisconnectedtomainspower. WhenitisconnectedtomainspowerthegreenLED Gison.
11
Invacare®Alegio™NG

3.5Wiring

NOTICE!
–Thecablesmustbemountedinsuchaway
thattheyarekeptclearofftheooranddo notblockthecastors.
Inordertopreventthecablesfrombeingdamagedwhen activatingthemotors,followtheinstructionsbelow.
1.
3.
a.Routetheheadsectionmotorcableovertheshear
armassemblycrosstubeandintothemotorpipepin andhookonthemattresssupportcrosstube.
b.Plugcableintothemotorandsecurewithlockingclip.
2.
a.Routethethighsectionmotorcableovertheshear
armassemblycrosstube.
b.Plugcableintomotorandsecurewithlockingclip.
Routethepowercablethroughthesheararmassembly hooks.
4.Routethehandcontrolcableunderthebaseframe.

3.6Installingbedends

Allenkey

3.6.1Bedendbrackets

Dependingonthebedendtobemounted,itmightbe requiredtopre-mountorchangethebedendbrackets.
Mounting
1.Insertthebedendbracketsintothesidetubesofthe mattresssupportplatform.
2.Fixthebedendbracketsonthesidetubeswiththe screwsfrombelowandtightenrmly.
Dismounting
1.Removethescrewsandpullthebedendbracketsoutof thesidetubes.
12
1563578-H
Setup
3.6.2BedendswithU-bracketstyletting
Mounting
1.LowerthebedendintotheU-brackettting.
2.Pressdownrmlyandensurethebedendisfullyseated atthebottomoftheU-brackettting.
Dismounting
1.Holdthebedendrmlyoneachsideandpullup verticallyonbothsidesatthesametime.
3.6.3BedendswithSannestyletting
CAUTION! Riskofsqueezing
Ifthebedendisnotcorrectlylockeditcanfall downandcauseinjurytouser .
–Makesurethelockingpinsareengaged.
Mounting

3.6.4SabrineandCamilabedends

Mounting
1.Fixthebedendbracketsonthebedendpanelwith thescrews.
2.Insertthebedendbracketsintothesidetubesofthe mattresssupportplatform.
3.ForSabrinebedends,xthebedendonthesidetubes withthengerscrewsinsertedinthesecondhole.In somecongurationsyouhavetoinsertthengerscrews intherstholetoxthefootend. ForCamilabedends,xthebedendonthesidetubes withthescrews.
Dismounting
1.Unscrewthengerscrewsorscrews,thatxthebed endonthesidetubes.
2.Pulloutthebedendpanelwiththebedendbracketsof thesidetubesofthemattresssupportplatform.
1.Aligntheslotsinthebedendwiththetabsonthe Sannetting.
2.Placethebedendontothetabs.
3.Pushdownrmlyandensurethatthebedendisfully seatedinthetabs.
4.Rotatethelockingpinonbothsidestoallowitto engagewiththebedend.
Dismounting
1.Pulloutthelockingpinandrotatetotemporarily disengagefromthebedendonbothsides.
2.Holdthebedendrmlyoneachsideandpullup verticallyonbothsidesatthesametime.

3.7Installingsiderails

WARNING! Riskofpersonaldamage
Thereisariskofentrapmentorsqueezing,while assemblingordisassemblingthesiderail.
–Payattentiontoyourngers. –Followinstructionscarefully. –Aftereachassembly,checkthatallttingsare
properlytightenedandthatthesiderailhas thecorrectfunction.
Removable3/4lengthsiderails
WARNING! Riskofentrapment
There’sariskofentrapmentorsuffocation betweenmattresssupport,siderailandbedend.
–Whenusingremovablesiderails,alwaysmake
surethatthedistancebetweenthebedend andthesiderail’shandleupperedgeisless than6cmintheheadendandmorethan32 cminthefootendofthebed.

3.7.1VersoIIsiderail

Mounting
1563578-H13
Invacare®Alegio™NG
Themountingofthesiderailmustbedonewiththe siderailinlockedposition.
1.Placebothbracketsofthesiderailontheframeofthe bed,withthelockingbuttonAfacingtowardsthefoot endofthebed.
2.Ensurethatthebracketneartheheadendofthebedis placedencompassingtheliftingpolesupportasshown indetailB.
3.ForbedsequippedwithbedendswithSannestyle tting,itisbeforehandnecessarytotemporarily disengagethelockingpinCfromtheheadbedend toplacethebracket. a.PullthelockingpinCandrotate1/4turntolockit
inthedisengagedposition.
b.Positionthebracketunderthelockingpinas
describedinstep2.
c.Rotatethelockingpinandallowittoengagewith
thebedend.
4.Afterthebracketsarepositionedcorrectlyontheframe ofthebed,xthesiderailbyrmlytighteningthe ngerscrewsD.
Dismounting
1.Untightenthengerscrewsandliftthesiderailofthe bedframe.

3.7.2Scala2siderail

Mountingsiderail
1.
Placethesiderailoverthetopframewiththerelease systemAattheheadendofthebed.
Theforklinksonthesiderailmustbemounted accordingtotheinstructiononthesiderail.
2.
TightenthengerscrewsBtoattachthesiderailon thetopframe.Makesureitissteadyandfastened.
Dismountingsiderail
1.LoosenthetwongerscrewsBandremovetheside rail.

3.7.3BrittVandLinesiderail

WARNING! Riskofentrapment/suffocation
Theusercangettrappedorfalloutofthebedif thesiderailisnotcorrectlymountedordamaged.
–Makesurethatallglidingshoesarecorrectly
guidedintothebedendguideways.
–Makesurethatallsiderailbarsareabovethe
lockingpinandproperlylocked.
–Makesurethatthestrapsbetweenthebarsare
notdamagedorloose.
Mounting
1.Lifttheupperbarinoneendofthesiderail.The releasebuttonsCmustfaceup/outwards.
2.PressinthelockingpinAintheendofthesiderail.
14
1563578-H
Setup
3.GuidethethreeglidingshoesB(intheendoftheside railbars)upintothebedendguideways,untiltheyhave allpassedthelockingpinD.
4.Repeatsteps2and3tomounttheothersideofthe siderail.
Dismounting
1.Lowerthesiderail.
2.Liftthelowerbar,inoneend,tomakethelockingpin Dvisibleandpressitinwithascrewdriver.
3.Lowerallthreebars,untiltheyareoutoftheguideways.
4.Repeatsteps2to3todismounttheotherendofthe siderail.

3.7.4Lisasiderail

Installingthesiderail
Allenkey
WARNING! Riskofentrapment/suffocation
Theusercangettrappedorfalloutofthebedif thesiderailisnotcorrectlymountedordamaged.
–Makesurethatallglidingshoesarecorrectly
guidedintothebedendguideways.
–Makesurethatthelockingscrewandtab
areproperlyinstalledatthebottomofthe guideways.
Attachingtheglidingsystemandinstallingthe siderail
1.Raisethebedto1/3offullheight.
2.
Removethescrewsofthebedendbracketsonboth sidesofonebedend.
3.
Assemblingtheglidingsystem
1.
PushthepawlAfromthebackside,throughtheglider Bandmakesureitlockswithanaudibleclick.
2.Dothesameforallfourpawlsineachglider.
Loosenthescrewandtabatthebottomofthe guidewaysonthebedendsandononesidepushthe gliderhalfwayupintotheguidewayuntilitattaches withanaudibleclick.
4.
Pushtheuppersiderailontothetwoupperpawls.
5.
Intheotherendofthesiderailbar ,pushthetwoupper pawlsintotheendofthebar.
1563578-H15
Invacare®Alegio™NG
6.
Pushtheattachmentintotheguidewayuntilitattaches withanaudibleclick(=properlyengagedinthelower position).
7.Mountthelowersiderailbarinbothendsasinstep4.
8.Pushthesiderailinbothends,allthewayupuntilthe upperbarlocksintheupperposition.
9.
4.Reinstallthefootbedendandxittothebracketswith thetappingscrews.
NOTICE!
Onanextendedbed,thefootbedendmust besecuredbyxingittothebracketswith tappingscrews.
5.
Attachmattressdeckextendertothefootendofthe mattressdeck.
3.9InstallRastox
(optional)
1.PressbottomofRastoxatthefootendofthebed.
Retightenthescrewandtabunderthelowersiderail bar,ineachcornerofthebedends.
10.Reinsertandtightenthescrewsofthebedendbrackets removedinstep2.
3.8Installingthemattresssupport
extension
(optional)
1.Removethefootbedend.
2.
Loosenthescrewsthatsecurethestandardbedend bracketsandremove
3.Inserttheextendedlengthbedendbracketsintothe frametubesandsecurewithscrews.
2.SqueezeupperendofRastoxtogether.
3.RotateRastoxbetweentabsandrelease.
4.Slidetheplasticcapandlockthebottomoftherastox.

3.10Dismantlethebed

1.Lockallcastorsandremoveallaccessories,endboards andmattress.
2.Bringthebedtoitslowestpositionandadjustall mattresssupportsectionstohorizontalposition.
3.Disconnectthepowercablefromthemainssocket.Roll thecableontothecontrolboxandliftmotor.
Ifthebedisprovidedwithacableactuatedfoot section,followstep4.Otherwiseproceedwithstep
5.
161563578-H
Setup
4.Unfastencablefromfootsectiondeckbracket,being suretoretaintheclevispinandhitchpin.
5.Unscrewthethreadedknobsfromthemiddleofboth sidesofthebedframe.
6.Pulltheheadsectionawayfromthefootsectionto disengagebracketsandplasticglides.
7.Onthefootsection,rotatethelockingpinsandthe snap-lockttings.Pullthefootsectionupandaway fromthesheararmpivotpins.
1563578-H
17
Invacare®Alegio™NG
A

4Operatingthebed

4.1GeneralSafetyInformation

WARNING! Riskofpersonalinjuryanddamagetoproperty .
–Thebedmustbeplacedsothattheheight
adjustmentisnotobstructedby,forexample, liftsorfurniture.
–T akecarethatnobodypartsarebeingsqueezed
betweenxedparts(suchassiderails,bed endsetc)andmovingparts.
–Thehandcontrolmustnotbeusedbychildren.
WARNING! Riskofinjury
Ifthebedisusedbyconfusedorrestlessusers oruserswithspasms:
–either ,whenthebedisequippedwitha
lockablehandcontrol,lockthehandcontrol functions,
–ormakesurethatthehandcontrolisoutof
reachfortheuser .

4.1.1Mattressretainers

WARNING! Riskofinjury
Withoutproperlyinstalledmattressretainers,the mattresscanslipsidewaysandcausetheuserto falloutofthebed.
–Neverusethebedwithoutmattressretainers. –Alwaysmakesurethemattressretainersare
properlyinstalledandfacingupwards.
–Onlyusetheoriginalmattressretainers.

4.2Handcontrol

Thehandcontrolcanbeequippedwitheithertwoorfour buttons.
Sittingposition
1.Up:pressleftsideofthebutton(p).
2.Down:pressrightsideofthebutton(q).

4.3Lockingfunction

Thelockingfunctionpreventsusageofcertainfunction buttons.Regardlessofhowmanybuttonsyourhandcontrol has,theycanallbelockedindividually.
1.InsertkeyAinthekeyholelocatedjustabovethe desiredfunction.
2.Tolock,turnthekeyclockwise.
3.Tounlock,turnthekeyanti-clockwise.

4.4Operatingsiderails

WARNING! Riskofentrapmentorsuffocation
There’sariskofentrapmentorsuffocation betweenmattresssupport,siderailandbedend.
–Alwaysensurecorrectttingandtighteningof
thesiderails.
WARNING! Riskoffalling
Ifithasbeendecidedthattheuserneedsside rails:
–Neverleavetheuserunattendedinthebed
withthesideraildown.
–Makesurethesiderailisinitshighestposition
andproperlylockedwhileleavingtheuser unattended.
CAUTION! RiskofInjury
Ifthesiderailisnotlockedproperlyitcanfall down.
–Pull/pushthetopbarofthesiderailtoensure
thatthelockingsystemisproperlyengaged.
Backrestsection
1.Up:pressleftsideofthebutton(p).
2.Down:pressrightsideofthebutton(q).
Thighsection
1.Up:pressleftsideofthebutton(p).
2.Down:pressrightsideofthebutton(q).
CAUTION! RiskofInjury
Thereisariskofentrapmentorsqueezingwhile operatingthesiderail.
–Payattentiontoyourngersandbodyparts
ofthepatient.
–Neverforceordropthesiderailwhilehandling
it.
Heightadjustment
1.Up:pressleftsideofthebutton(p).
2.Down:pressrightsideofthebutton(q).
181563578-H
Operatingthebed
B
A

4.4.1VersoIIsiderails

Foldingdowntoopenthesiderail
1.HoldthetopbarBwithonehandandpullthelocking buttonAwiththeotherhand.
2.Pullthetopbarsidewardsandreleasethelocking button.
3.Foldthesideraildowntoitslowestposition.
Foldinguptoclosethesiderail
1.PullthetopbarBandraisethesiderailuntilitis properlyengagedinthelockingsystem.

4.4.3BrittVandLinesiderails

Lock/Upperposition
Pullupthetopwoodenside railbar ,untilthelockingpin lockswithanaudibleclick
Release
Liftthetopwoodenside railbarandpressthetwo lockingringstogether.
Down/Lowerposition
Lowerthesiderail.
Usingasiderailheightextender

4.4.2OperatingScala2siderail

NOTICE!
–Whenmanoeuvringthesiderail,placeyour
handsonlyintheareasmarkedwiththegrip label.
1.2.
1.Up:LiftandpullthetopbarBofthesiderailtowards theendwiththelockingmechanism(releasebutton)A .Ensure,itislockedinplace.
2.Down:PressthereleasebuttonAandpushthetopbar Bofthesiderailawayfromthelockingmechanism.
LineandBrittVsiderailscanbesupplementedbyaheight extender .Asiderailheightextenderincreasestheallowed mattressthicknessby15cm.
WARNING! Riskofinjuryordeath
Amisappliedsiderailheightextendercouldfall off.There’sanincreasedriskfortheusertofall outofthebed.
–Makesurethatthesiderailheightextenderis
properlyattachedtothesiderail.Refertothe usermanualofthesiderailheightextender .
–Makesuretousethecorrectheightextender
foryoursiderail(theshapemustmatchto theshapeofthesiderail.Alabelonthe heightextenderdeterminestowhichsiderailit belongs.Seeimagebelow.
HeightextenderforLINE siderail:
HeightextenderforBRITTV siderail:
1563578-H19
Invacare®Alegio™NG
A
B
B
A

4.4.4Lisasiderail

Operatingthesiderail
Raisethesiderail
1.Usethetwohandlesontheupperbartoraisetheside railuntilitlocksintheupperpositionwithanaudible click.
Lowerthesiderail
1.
PresstheglidingsystemlatchAononeendofthebed andlowerthesiderailtothelowestposition.
2.Repeattheprocedureattheotherendofthebed.

4.5.2Centralbrakesystem

Allthewheelsarelockedbylockingoneofthepedals.
Alwaysstandinthemiddleofthebed'slongside whenlockingthebrakes.
1.Lockthebrakes: StepontheredpedalB.

4.5Castorsandbrakes

CAUTION! Riskoftrapping/squeezing
Allbrakesarefoot-operated.
–Donotreleasethebrakewiththengers.
CAUTION! Riskofinjury
Usercanfall,whileenteringorexitingthebed,if brakesarenotlocked.
–Alwayslockthebrakesbeforetheuseris
movinginoroutofbedorwhenattendingto theuser.
Castorsmightmakemarksondifferenttypesof absorbingoorsurfaces-suchasuntreatedor badlytreatedoors.T opreventmarks,Invacare® recommendstoplaceasuitablekindofprotection betweenthecastorsandtheoor.

4.5.1Castorbrake

1.Unlockthebrakes: Steponthegreenpedal Auntilthebrakeisin neutralposition=Both pedalsonthesame level.

4.6Liftingpole

WARNING! Riskofinjury
Thebedcantipifthehandleisused,whilethe liftingpoleisturnedawayfromthebed.
–Theliftingpolealwayshastobepositioned
withthehandlehangingoverthebedarea.
–Donotexceedthemaximumloadofthelifting
pole;80kg.

4.6.1Placetheliftingpole

Theliftingpolecanbeplacedeitherontheleftortheright sideoftheheadendofthebed.
1.Inserttheliftingpoleintotheliftingpoletubeandxit withthengerscrew.
It’snotrequiredtotightenthengerscrew,incase youwanttheliftingpoletoswingawaytotheside ofthebed.
Lockingthebrake-StepontheouterpartBofthebrake pedal
Unlockingthebrake-StepontheinnerpartAofthebrake pedal
201563578-H
Operatingthebed
A
A

4.6.2Adjustingthehandleheight

Thehandleheightshouldalwaysbeadjustedtotheuser’s need.
1.2.
1.HoldthecordoutwhileslidingtheplasticcordlockA upwardsordownwardsuntilthehandlereachesthe preferredheight.
2.Lockthehandlebypressingbackthecordinthelock Aandpullthehandledownwards.
NOTICE!
Afteradjustingthehandleheight:
–Checkthatthetwocordsabovethecordlock
areparallelandinsidethecordlock.
–Makesurethecordisproperlylockedbypulling
thehandlehard.
incaseofpowerfailureorurgentneedforaction,use themanualemergencyreleaseandlowerthemattress supportsection.
Referto4.8.1Emergencyreleaseofamattresssupport
section,page21
.

4.8.1Emergencyreleaseofamattresssupport section

Incaseofapower-ormotorfailure,anemergencyrelease oftheback,thighorlegsectioncouldbenecessary.An emergencyreleaseoftheheightadjustmentisNOTpossible.
CAUTION! Riskofinjury
–Aminimumoftwopersonsisrequiredfor
anemergencyreleaseofamattresssupport section.
–Whenreleasingamattresssupportsection,
itmightlowerfast.Donotreachunderthe mattresssupportwhileloweringit.
NOTICE!
–Beforeanemergencyreleaseofthemattress
support,removetheplugfromthemains socket.

4.7Adjustingthelegsection

Operatethelegsectionbyliftingthemattresshandle:
1.Up:Liftthemattresshandleonthelegsection.
2.Down:Liftthemattresshandleonthelegsectionright
upandthenlowerthelegsection.

4.8Emergencypositions

Incaseofamedicalemergency,itmightberequiredto bringallorcertainmattresssupportsectionsintoaattened position-e.g.aattenedbacksectionforcardiopulmonary resuscitation(CPR).
Tobringamattresssupportsectionintoaattenedposition,
usethecorrespondingfunctiononthehandcontrol
1.Bothpersonsholdthemattresssection.
2.Oneofthemlocatesthemotorinquestionandpulls
outthesafetypin.
3.Bothpersonsslowlylowerthemattresssectionuntilit
iscompletelydown.

4.9TransportationandStorage

Thebedcanbetransportedorstoredinassembledor disassembledstate.
See3.10Dismantlethebed,page16fordetailedinstructions onhowtodisassemblethebed.
Totransportorstorethebedinitsassembledstate:
1.Disconnectthepowercablefromthemainssocket.
2.Coilupthepowercableandplaceitaroundtheside
tubeofthebed,soitiskeptclearoftheoorand damageduringtransportorstorageisprevented.
OR
1563578-H
21
Invacare®Alegio™NG

5Options

5.1Listofavailableoptions

Duetoregionaldifferences,refertoyourlocal Invacarewebsiteorcatalogfordetailsaboutavailable optionsorcontactyourInvacareprovider .
Siderails –VersoII
3/4lengthcollapsiblesteelsiderailmountedonthe sidetube.Releasebuttoninthefootsection
–ScalaBasic2
3/4lengthcollapsiblesteelsiderail,mountedonthe sidetube.Releasebuttonintheheadsection
–ScalaBasicPlus2
3/4lengthcollapsiblesteelsiderail,mountedonthe sidetube.Releasebuttonintheheadsection
–ScalaMedium2
3/4lengthcollapsiblesteelsiderailmountedonthe sidetube.Releasebuttonintheheadsection
–BrittV
Fulllengthcollapsiblewoodsiderailmountedonthe bedendguideways.Releasebuttonsinthemiddle
–Linestandard
Fulllengthcollapsiblealuminiumsiderailmounted onthebedendguideways.Releasebuttonsinthe middle
–Lineextendable
Fulllengthcollapsiblealuminumsiderailwith telescopicextensionmountedonthebedend guideways.Releasebuttonsinthemiddle
–Lisa
Fulllengthcollapsiblewoodsiderailmountedonthe bedendguideways.Releasebuttonsinbothends
–HeightextendersforBrittVandLinesiderails
Mattresssupportextension(footend)–15cm
Liftingpole
IVdriprod
Fixedsupporthandles–40cmx30cmand40cm x50cm
Handcontrols –withbackandheightadjustment –withsittingpositionandback,thighandheight
adjustment
–withsittingpositionandback,thighandheight
adjustment(lockable)
Rastox
Transporttrolley
NOTICE!
–Useonlyoriginaloptionandspareparts.Spare
partslistsandextrausermanualscanbe orderedfromInvacare.

5.2Transporttrolley

Thetransporttrolleyisnotcompatiblewithbeds equippedwithcentralbrake.
22
1563578-H
Options
Mountingthebedonthetransporttrolley
1.Locktrolleycastors.
2.
MountthefootsectionontothetubesAwiththemotor facingawayfromthetrolleycross-channelE.Secure thefootsectiononthetrolleywiththengerscrews.
3.
5.
a.Lockthebrakesofthe2bottomcastorsofthebed
baseandpositiontheminwardstoavoidthatthey touchthegroundduringthemanipulation.
b.Alignsquareglidebushingsofbaseassemblywith
bracketsDandpushthebedbaseontothetrolleyas faraspossible.
6.
PlacetheliftingpoleontoitslocationB.
4.
MounttheheadsectionontothetubesCwiththe motorfacingawayfromthetrolleycross-channelE. Securethefootsectiononthetrolleywiththenger screws.
Liftendofbaseassemblyintoaverticalposition, allowingthesquareglidebushingstoengageintothe bracketsD.Securebasetotrolleywithspringpins.
1563578-H23
Invacare®Alegio™NG
7.
PlacetheVersoIIsiderails(ifapplicable)into cross-channelofthetrolleyE.
8.
Placebedends(ifapplicable)ontotrolleyhooksF.
24
1563578-H
Maintenance

6Maintenance

6.1Generalmaintenanceinformation

CAUTION! Riskofinjuryordamage
–Donotperformanymaintenanceorservice
procedureswhiletheproductisinuse.
Followthemaintenanceproceduresdescribedinthismanual tokeepyourproductincontinuousoperation.

6.2Dailyinspections

WARNING! Riskofinjuryordamage
Damagedorwornpartscanaffectthesafetyof theproduct.
–Theproductshouldbecheckedeachtimeit
isused.
–Donotusetheproductifdamageisfound
oryouquestionthesafetyofanypartof theproduct.ContactyourInvacareprovider immediatelyandensuretheproductisnotused untilrepairsaremade.
DailyInspectionChecklist
qVisuallyinspectthebed.Checkallpartsforexternal
damageorwear .
qCheckallhardware,attachmentpoints,stressedparts
andanypivotpointsforsignsofwear,cracking,fraying, deformationordeterioration.
qCheckthehandcontrolandallactuatorsforsmooth
operation.
Everyyear
Werecommendasafetytestcomprisingtheactuators’ performanceandmechanicalstate.
Everysecondyear
Westronglyrecommendaserviceaccordingtothe belowchecklistaftertwoyearsofnormaluseandthen everysecondyear .
Actuators,handcontrolandcontrolunitareserviced byexchangingthefaultypart.

6.4Checklist-Maintenance

Checkpoints
qCirclips,cotterpinsandplasticxingring-properly
lockedandintact.
qScrews-tightened. qWeldings-intact. qSideraillockingandmovingsystem-properlylocking
andrunningsmoothly .
qCastorttings-tightened. qCastorbrakes-lockingproperly . qHeightadjustmentmotor-runningproperly. qBackrestmotor-runningproperly. qThighsectionmotor-runningproperly. qWires-correctlywiredandundamaged. qElectricplugs-undamaged. qDamagedcoating-repaired. qLinesiderailstraps-notfrayedorcracked. qAccessories-correctlyassembledandcorrectfunction. qRastoxtting-checkfunction. qMotors,controlunitandhandcontrol-keepcleanfrom
dustanddirt.Checkfordamage.
qAnchorpoints,cables,pistonrod,casingandplugs-
Checkfordamage.

6.3Generalservicinginformation

NOTICE!
–Themattresssupportmustbesupported
duringserviceinspections,topreventaccidental lowering.
–Onlypersonnelwhohavereceivedthe
necessaryinstructionsortrainingmayperform serviceandmaintenanceofthebed.
–Afterreconditioningthebed,orifbedfunctions
change,servicemustbecarriedoutaccording tothechecklist.
Aservicecontractcanbemadeinthecountries,where Invacarehasitsownsalescompany.Incertaincountries Invacareofferscoursesinserviceandmaintenanceofthe bed.Sparepartslistsandadditionalusermanualsare availablefromInvacare.
BeforeUse
Ensurethatallmanualandelectricalpartsfunctions correctlyandareinasecurestate.
Check,byraisingandloweringthebed,thattheshear armsrunsmoothlyintheguideways.
Afterthreemonths
Ensurethatallmanualandelectricalpartsare functioning,andtightenbolts,screws,nuts,etc.

6.5Inspectionafterrelocation-Prepare fornewuser

NOTICE!
Whenthebedhasbeenrelocated;beforegiven toanewuserithastobethoroughlyinspected.
–Inspectionmustbedonebyatrained
professional.
–Forregularmaintenanceseemaintenancechart.

6.6Checklist-Afterrelocation

Checkpoints
qCheckthettingsbetweensheararmandmattress
support(screwstightenedproperly).
qCheckthelockingofthemotors(pipepinscorrectly
mounted).
qChecktheelectronicwiringforthemotors(wiresnot
squeezed).
qCheckthattheenclosingofthemotorsareintact(no
cracksthatenablesuidstopierce).
qCheckthesectionsofthemattresssupportbyusing
thehandcontroltoactivateallfunctionsofthemoving parts.
qCheckthefunctionofthebrakes.
1563578-H25
Invacare®Alegio™NG
qCheckthelockingfunction(s)ofthesiderails.

6.7CleaningandDisinfection

6.7.1Generalsafetyinformation

CAUTION! Riskofcontamination
–T akeprecautionsforyourselfanduse
appropriateprotectiveequipment.
CAUTION! Riskofelectricshockandproductdamage
–Switchoffthedeviceanddisconnectfrom
mains,ifapplicable.
–Whencleaningelectroniccomponentsconsider
theirprotectionclassregardingwateringress.
–Makesurethatnowatersplashestotheplug
orthewalloutlet.
–Donottouchthepowersocketwithwethands.
NOTICE!
Wronguidsormethodscanharmordamage theproduct.
–Allcleaningagentsanddisinfectantsusedmust
beeffective,compatiblewithoneanotherand mustprotectthematerialstheyareusedto clean.
–Neverusecorrosiveuids(alkalines,acidetc.)
orabrasivecleaningagents.Werecommend anordinaryhouseholdcleaningagentsuchas dishwashingliquid,ifnotspeciedotherwisein thecleaninginstructions.
–Neveruseasolvent(cellulosethinner ,acetone
etc.)thatchangesthestructureoftheplastic ordissolvestheattachedlabels.
–Alwaysmakesurethattheproductiscompletely
driedbeforetakingintouseagain.
Forcleaninganddisinfectioninclinicalorlong-term careenvironments,followyourin-houseprocedures.
Cleaningagent:Werecommendusingamilddetergent withneutralornearneutralpH(5-9).
Commerciallyavailableconsumerproductslike handdishwashingliquidorall-purposecleaners canbeused.Readtheinstructionsonthe labelofyourcleaningagentanduseitatthe indicatedconcentration.
Max.watertemperature:40°C
1.Wipesurfacesthoroughlywithasoftclothslightly moistenedwithdetergentsolutionuntilallvisiblesoil isremoved.
2.Removealldetergentresiduewithacleandampcloth.
3.Wipedryusingacleansoftcloth.
Removabletextiles(includingupholsteryandmattresses)
Seeattachedlabeloneachproduct.

6.7.4DisinfectionInstructions

InDomesticCare
Disinfectant:Werecommendusinganalcohol-based surfacedisinfectant(with70-90%alcohol).
Readtheinstructionsonthelabelofyour disinfectant.Itprovidesinformationonthe activityspectrum(bacteria,fungiand/orviruses), materialcompatibilityandthecorrectexposure time.
1.Ensurethesurfacesarecleanedbeforedisinfection.
2.Moistenasoftclothandwipe-disinfectallaccessible surfacesandkeepthemmoistenedfortheexposure timestatedonthelabelofthedisinfectant.
3.Allowtheproducttoair-dry.
InInstitutionalCare
Followyourin-housedisinfectionproceduresandonlyuse thedisinfectantsandmethodsspeciedtherein.

6.8Lubrication

6.7.2CleaningIntervals

NOTICE!
Regularcleaninganddisinfectionenhancesmooth operation,increasestheservicelifeandprevents contamination. Cleananddisinfecttheproduct:
–regularlywhileinuse, –beforeandafteranyserviceprocedure, –whenithasbeenincontactwithanybody
uids,
–beforeusingitforanewuser .

6.7.3CleaningbyHand

Allcomponents(excludingremovabletextiles)
Werecommendlubricatingthebedaccordingtothe followingtable:
PartofbedLubricationmethod
Pointsofrotationinmattress supportandbaseframe
Motorattachmentpointsto mattressplatform
Upperattachmentpointof Rastoxtting
Scissorpivotboltsand attachmentbolts
Fororderingofcorrectoilandgrease,pleasecontact yourInvacaredealer.
Oil(medicallyclean)
Oil(medicallyclean)
Oil(medicallyclean)
Oil(medicallyclean)
261563578-H
AfterUse

7AfterUse

7.1Disposal

Beenvironmentallyresponsibleandrecyclethisproduct throughyourrecyclingfacilityatitsendoflife.
Disassembletheproductanditscomponents,sothedifferent materialscanbeseparatedandrecycledindividually .
Thedisposalandrecyclingofusedproductsandpackaging mustcomplywiththelawsandregulationsforwaste handlingineachcountry.Contactyourlocalwaste managementcompanyforinformation.

7.2Reconditioning

Thisproductissuitableforreuse.Toreconditiontheproduct foranewuser,carryoutthefollowingactions:
Inspection
Cleaninganddisinfection
Fordetailedinformation,see6Maintenance,page25.
Makesurethattheusermanualishandedoverwiththe product.
Ifanydamageormalfunctionisdetected,donotreuse theproduct.
1563578-H
27
Invacare®Alegio™NG

8Troubleshooting

8.1Troubleshootingelectricalsystem

Symptom
Mainsindicatorlightsup,butthemotor isnotrunning.Therelayinthecontrol unitmakesaclickingnoise.
Mainsindicatorlightsup,butthemotor isnotrunning.Norelaysoundisheard fromthecontrolunit.
Controlunitisinorderexceptforone directionononechannel.
Motorisrunning,butthepistonrod doesnotmove.
Themotorcannotliftfullload.
Motornoise,butnomovementof pistonrod.
Pistonrodoperatesinwardsandnot outwards.
*Serviceandmaintenanceofthebedmustonlybeperformedbypersonnelwhohavereceivedthenecessaryinstructionor training.
PossiblecauseRemedy
Mainsarenotconnected
Fuseinthecontrolunitisblown
Controlunitisdefective
Motorplugisnotfullyinsertedintothe controlunit.
Themotorisdefective.
Motorcableisdamaged.
Controlunitisdefective
Controlunitisdefective
Handcontrolisdefective
Controlunitisdefective
Handcontrolisdefective
Motorisdamaged
Connectmains
*Replacethecontrolunit Mainsindicatordoesnotlightup
*Replacethecontrolunit
Insertthemotorplugproperlyintothe controlunit
*Replacethemotor
*Replacethecable
*Replacethecontrolunit
*Replacethecontrolunit
*Replacethehandcontrol
*Replacethecontrolunit
*Replacethehandcontrol
*Replacethemotor
Riskofpersonalinjuryanddamagetotheproduct.
–Thebedmustbeunpluggedfromthemainpowersourcebeforeopeningorrepairingelectricalparts.
WARNING! Riskofpersonalinjuryanddamagetotheproduct.
–Thebedmustbeunpluggedfromthemainpowersourcebeforeopeningorrepairingelectricalparts.
281563578-H
TechnicalData

9TechnicalData

9.1Materials

MattressPlatform
BedEnds
SideRails
LiftingPole Actuatorshousing,
Handcontrol, Controlbox,Castors andotherPlastic parts
Boltsandnuts
Matressretainers

9.2Dimensions

Steel(powder-coated)
Steel(powder-coated)andMDF Steel(powder-coated),woodor
aluminium Steel(powder-coated),PPandPOM
Materialaccordingtomarking(PA,PP , PE,ABS)
Steel(Zinc-plated)
ABS
Dimensions[cm]
TotallengthH
Totalheight(withlifting pole)I
Mattresssupporttooor heightJ
BasetooorheightK
Alldimensionsarestatedwithouttolerancesfora non-extendedbedwithcastorsof125mmdiameter .
153-205
28-80

9.3Weights

MaximumLoads
Max.patientweight (providedthattheweightofthe mattressandtheaccessoriesdonot exceed35kg)
Max.safeworkingload (patient+accessories)
211
16
135kg
170kg
MattresssupportwidthA
TotalwidthB (dependingonbedend)
MattresssupportlengthC
BacksectionlengthD
SeatsectionlengthE
ThighsectionlengthF
LegsectionlengthG
Dimensions[cm]
90
Emma,Vibeke,Piggy:90
Sabrine:95
Anita,Susanne,Sophie,
Victoria:100
Camila:102
200
80
23
30
67
BedPartsandAccessories
AlegioNGstandardbed,complete,excluding accessories Mattresssupport,standardheadend14.0kg
Mattresssupportwithauto-regression,head end Mattresssupport,footend,15.5kg
Mattresssupport,footend,footmotor17.0kg
Mattresssupport,footendthighmotor17.0kg
Baseandsheararm35.0kg
Base
Sheararm19.5kg
BedEnd,Vibeke–1piece6.0kg
BedEnd,Emma–1piece7.0kg
BedEndSusanne/Sophie–1piece
BedEnd,Camila–1piece11.0kg
BedEnd,Sabrine–1piece6.8kg
BedEnd,Victoria–1piece10.0kg
BedEnd,Piggy–1piece6.0kg
BedEnd,Anita–1piece9.0kg
Liftingpole4.2kg
Rastox0.3kg
Mattresssupportextension(15cm)
65.0kg
17.0kg
15.5kg
8.5kg
1.8kg

9.4MattressDimensions

Allowedmattresssizes,dependingonthesiderail
Mattressmeasures(incm)
SiderailHeightWidthLength*
Versoll10–1885,5–95195–206
Linesiderail12–2085,5–95195–206
1563578-H29
Invacare®Alegio™NG
Lisasiderail12–1785,5–95195–206 BrittVside rail12–2085,5–95195–206
ScalaBasic210–1785,5–95195–206 ScalaBasic Plus210–1785,5–95195–206 ScalaMedium 210–2285,5–95195–206
*Forbedsequippedwithamattresssupportextension,add 15cm.
Min.density:38kg/m

9.5SideRails

SideRail
VersoII 3/4lengthcollapsiblesteel siderail
ScalaBasic2 3/4lengthcollapsiblesteel siderail
ScalaBasicPlus2 3/4lengthcollapsiblesteel siderail
ScalaMedium2 3/4lengthcollapsiblesteel siderail
BrittV Fulllengthcollapsible woodsiderail
Linestandard Fulllengthcollapsible aluminiumsiderail
Lineextendable Fulllengthcollapsible aluminumsiderailwith telescopicextension
Lisa Fulllengthcollapsible woodsiderail
Measures [cm]
150x407.0
168x407.4
168x407.4
165x468.9
205x40
206x404.5
206-226x406.5
205x407.0
Weights [kg/pc]
7.7

9.6Environmentalconditions

Storageand
Transportation
Temperature Relativehumidity
Atmospheric pressure
Allowtheproducttoreachoperationtemperature beforeusage:
Warmingupfromminimumstoragetemperature mighttakeupto24hours.
Coolingdownfrommaximumstorage temperaturemighttakeupto24hours.
-10°Cto+50°C+5°Cto+40°C
20%to80%-notcondensing
700hPato1060hPa

9.7Electricalsystem

Voltage supply
Maximum currentinput
Intermittent (periodic motor operation)
Degreeof protection
Insulation class
TypeB AppliedPart
Soundlevel
Thebedhasnoisolator(mainswitch).Ifthebed needstobeelectricallydisconnected,ithastobe unpluggedfromthemainssocket.
Uin=230Volt,AC,50/60Hz(AC= Alternatingcurrent)
Iinmax.=1.5A
Int=10%,max.2min/18min
IPX6
Thecontrolunitandmotorsareprotected accordingtoIPX6.
IPX6–Theelectricalsystemisprotected againstwaterprojectedinpowerfuljets fromanydirection.
ClassIIequipment
AppliedPartcomplyingwiththespecied requirementsforprotectionagainstelectrical shockaccordingtoIEC60601-1.
45to50dB(A)
Operation
301563578-H
Electromagneticcompatibility(EMC)

10Electromagneticcompatibility(EMC)

10.1GeneralEMCinformation

MedicalElectricalEquipmentneedstobeinstalledandusedaccordingtotheEMCinformationinthismanual.
ThisproducthasbeentestedandfoundtocomplywithEMClimitsspeciedbyIEC/EN60601-1-2forClassBequipment.
PortableandmobileRFcommunicationsequipmentcanaffecttheoperationofthisproduct.
Otherdevicesmayexperienceinterferencefromeventhelowlevelsofelectromagneticemissionspermittedbytheabove standard.T odetermineiftheemissionfromthisproductiscausingtheinterference,runandstoprunningthisproduct.If theinterferencewiththeotherdeviceoperationstops,thenthisproductiscausingtheinterference.Insuchrarecases, interferencemaybereducedorcorrectedbythefollowing:
Reposition,relocate,orincreasetheseparationbetweenthedevices.

10.2Electromagneticemission

Guidanceandmanufacturer´sdeclaration
Thisproductisintendedforuseintheelectromagneticenvironmentspeciedbelow.Thecustomerortheuserofthis productshouldassurethatitisusedinsuchanenvironment.
Emissionstest
RFemissions CISPR11
RFemissions CISPR11
Harmonic emissions IEC61000-3-2
Voltageuctuations /ickeremissions IEC61000-3-3
ComplianceElectromagneticenvironment-guidance
ThisproductusesRFenergyonlyforitsinternalfunction.Therefore,itsRF
GroupI
ClassB
ClassA
Complies
emissionsareverylowandarenotlikelytocauseanyinterferenceinnearby electronicequipment.
Thisproductissuitableforuseinallestablishmentsincludingdomestic establishmentsandthosedirectlyconnectedtothepubliclow-voltagepower supplynetworkthatsuppliesbuildingsusedfordomesticpurposes.

10.3ElectromagneticImmunity

Guidanceandmanufacturer´sdeclaration
Thisproductisintendedforuseintheelectromagneticenvironmentspeciedbelow.Thecustomerortheuserofthis productshouldassurethatitisusedinsuchanenvironment.
Immunitytest
Electrostatic discharge(ESD)
IEC61000-4-2
Electrostatic transient/burst
IEC61000-4-4
Surge
IEC61000-4-5
Test/Compliancelevel
±8kVcontact
±2kV,±4kV,±8kV,± 15kVair
±2kVforpowersupply lines;100kHzrepetition frequency
±1kVforinput/output lines;100kHzrepetition frequency
±1kVlinetoline
±2kVlinetoearth
Electromagneticenvironment–guidance
Floorsshouldbewood,concreteorceramictile.Ifoorsarecoveredwith syntheticmaterial,therelativehumidityshouldbeatleast30%.
Mainspowerqualityshouldbethatofatypicalcommercialorhospital environment.
Mainspowerqualityshouldbethatofatypicalcommercialorhospital environment.
1563578-H31
Invacare®Alegio™NG
Immunitytest
Voltagedips,short interruptionsand voltagevariations onpowersupply inputlines
IEC61000-4-11
Powerfrequency (50/60Hz) magneticeld
IEC61000-4-8
ConductedRF
IEC61000-4-6
RadiatedRF
IEC61000-4-3
Test/Compliancelevel
<0%UTfor0,5cycleat 45°steps
0%UTfor1cycles
70%UTfor25/30cycles
<5%UTfor250/300 cycles
30A/m
3V 150kHzto80Mhz
6V inISM&amateurradio bands
10V/m 80Mhzto2,7GHz
385MHz-5785MHz testspecications forimmunitytoRF wirelesscommunication equipmentrefertotable 9ofIEC60601-1-2:2014
Electromagneticenvironment–guidance
Mainspowerqualityshouldbethatofatypicalcommercialorhospital environment.Iftheuserofthisproductrequirescontinuedoperationduring powermainsinterruptions,itisrecommendedthattheproductispowered fromanun-interruptiblepowersupplyorabattery.
UTisthea.c.mainsvoltagepriortoapplicationofthetestlevel.
Powerfrequencymagneticeldsshouldbeatlevelscharacteristicofa typicallocationinatypicalcommercialorhospitalenvironment.
Fieldstrengthsfromxedtransmitters,suchasbasestationsforradio (cellular/cordless)telephonesandlandmobileradios,amateurradio,AM andFMradiobroadcastandTVbroadcastcannotbepredictedtheoretically withaccuracy.ToassesstheelectromagneticenvironmentduetoxedRF transmitters,anelectromagneticsitesurveyshouldbeconsidered.Ifthe measuredeldstrengthinthelocationinwhichthisproductisusedexceeds theapplicableRFcompliancelevelabove,thisproductshouldbeobserved toverifynormaloperation.Ifabnormalperformanceisobserved,additional measuresmaybenecessary,suchasreorientingorrelocatingthisproduct.
Interferencemayoccurinthevicinityofequipmentmarkedwiththe followingsymbol:
PortableandmobileRFcommunicationsequipmentshouldbeusedno closerthan30cmtoanypartofthisproductincludingcables.
Theseguidelinesmaynotapplyinallsituations.Electromagneticpropagationisaffectedbyabsorptionandreection fromstructures,objectsandpeople.
10.3.1TestspecicationsforimmunitytoRFwirelesscommunicationsequipment
IEC60601-1-2:2014—Table9
TestFrequency
a)
Band
(MHz)
(MHz)
385380-390TETRA400
450430-470
710 745
704-787
788
810 870
800-960
930
Service
GMRS460,
FRS460
LTEBand13,17
GSM800/900,
TETRA800,
iDEN820,
CDMA850,LTE
Band5
a)
Modulation
Pulse
modulation
18Hz
FM ±5kHz deviation
1kHzsine
Pulse
modulation
217Hz
Pulse
modulation
18Hz
b)
Maximum
Distance(m)
power(W)
b)
c)
1.80.327
20.328
b)
b)
0.20.39
20.328
Immunitytest
level(V/m)
321563578-H
Electromagneticcompatibility(EMC)
TestFrequency
a)
Band
(MHz)
Service
a)
Modulation
(MHz)
b)
Maximum
Distance(m)
power(W)
GSM1800;
1720 1845
1700-1990
1970
CDMA1900;
GSM1900;
DECT;L TEBand
1,3,4,25;
modulation
217Hz
Pulse
b)
20.328
UMTS
Bluetooth,
24502400-2570
WLAN,802.11
b/g/n,RFID
2450,LTE
modulation
217Hz
Pulse
b)
20.328
Band7
5240 5500
5100-5800
5785
WLAN802.11
a/n
modulation
217Hz
Pulse
b)
0.20.39
Ifnecessarytoachievetheimmunitytestlevel,thedistancebetweenthetransmittingantennaandtheMedical ElectricalEquipmentorSystemmaybereducedto1m.The1mtestdistanceispermittedbyIEC61000-4-3.
a)
Forsomeservices,onlytheuplinkfrequenciesareincluded.
b)
Thecarriershallbemodulatedusinga50%dutycyclesquarewavesignal.
c)
AsanalternativetoFMmodulation,50%pulsemodulationat18Hzmaybeusedbecausewhileitdoesnotrepresentactual
modulation,itwouldbeworstcase.
Immunitytest
level(V/m)
1563578-H33
Notes
Notes
UnitedKingdom&Ireland:
UKR P
InvacareLimited PencoedTechnologyPark, Pencoed BridgendCF355AQ Tel:(44)(0)1656776200 uk@invacare.com www.invacare.co.uk
InvacarePortugal,Lda RuaEstradaVelha949 4465-784LeçadoBalio Portugal
InvacareUKOperations Limited Unit4,PencoedTechnology Park,Pencoed BridgendCF355AQ UK
1563578-H2023-02-23
MakingLife’sExperiencesPossible®
*1563578H*
Loading...