Installation and use of the Installation and use of the
RF
RF EEN
EEN----REC3
RF RF
EENEEN
REC3----RW Read Write receiver
REC3REC3
RW Read Write receiver
RW Read Write receiverRW Read Write receiver
Presentation
The EEN-REC3-RW receiver enables RF
control of two car park accesses called
"ENTRY" and "EXIT".
It accepts the 2 and 4-channel RF 868MHz
remote controls.
It is waterproof and can be attached to an
outside wall.
EEN-REC3-RW features:
- 12 24 V AC/DC – 100 mA.
- 2 1A 24V Relays.
Description of the unit's components
ECstandard
Terminals
6
Settings and reset
Remote control management:
- On the web
- Read/write mode from the web
- Max 2,500 remote controls
Ensure to note the receiver's
serial number. It will be
needed for managing your
remote controls from the
Internet.
Waterproof seal
Removable memory
LEDs
Waterproof cables pass through
Installation and user guide for the EEN-REC3-RW receiver
Page 1 / 6 V233 – 0012 – AA
Page 2
Cabling diagram:
T
T
- +
T1 C1
T2 C2 2 1
2 1
2 1A 2
4V Relays.
Power supply
1224 V AC/DC 100mA
With the wire
(Factory fitted)
With 868 MHz aerial
(NOT SUPPLIED)
C
C
POWER
2 Relays
ANT.
ANT.
Voltage-free
contact
to
the
device
to controlon
entry
Voltage-free
contact
to
device
to control
on exit
Woven
Core
Instructions to follow:
The receiver mustnot be enclosed in a metal case or placed behind a protective area that uses
wire netting. In the event that you cannot do otherwise, you must connect the 868 MHz aerial
that you will install outside.
To achieve satisfactory operation, there must be no metal obstacles between the active aerial and
the normal position used for operating the remote controls. It is therefore preferable to install the receiver in a high location to avoid obstacles (e.g. wire netting).
Drill the holes as accurately as possible in the cable grommets to prevent any water seeping into
the receiver. Failure to comply with this requirement will void the warranty.
Installation and user guide for the EEN-REC3-RW receiver
Page 2 / 6 V233 – 0012 – AA
Page 3
State Correspondence
1 flash every
3 seconds
2 flashes every
3 seconds
LED operation
New unit: The unit works with all Intratone remote controls whether or not
they are programmed. This state allows the installation of the EEN-REC3-RW receiver to be tested.
Unit in operation: The unit works with the remote controls programmed for
residents from the website. Access control is enabled. Only the owner
administrator of the receiver may authorise the remote controls for this unit.
Permanent slow
flashing
Light on for 1
second
Fast flashing
for 10 seconds
Fast flashing
for 2 to 3 seconds
Permanent fast
flashing
Pass option enabled: (See below).
RF reception from a remote control.
Activation of the central unit.
Programming of a new remote control.
Memory not present or invalid.
Activating the control unit
To activate the EEN-REC3-RW receiver, you must program the remote controls from the website:
Locate the serial number of the unit you wish to activate.
Log into the website using your login and password or by opening an account ("create an
account" button).
Create a residence and then an "EEN-REC3-RW" access type by entering the EEN-REC3-RW
receiver's serial number.
Then program the remote controls that you will distribute to the residents.
They will automatically open the accesses controlled by the receiver. The first of them will
activate the control unit.
If you need to program pass remote controls, you will need to enable the pass option by programming
a specific remote control on the website ("Enable Pass Option” button on the screen of the receiver in
question).
In front of the receiver, pass this remote control to activate the "Pass Option." The pass remote
controls will now open.
Installation and user guide for the EEN-REC3-RW receiver
Page 3 / 6 V233 – 0012 – AA
Page 4
Switches
The ON state is the high position, whereas the OFF position is the low position. The receiver is
supplied with the 6 switches in the OFF position corresponding to the following operation:
The relays are set to 5 second unlock times
Receiver set for the I (ENTRY) and II (EXIT) buttons of the remote controls.
For 2-button remote controls:
The left button triggers the ENTRY relay while the right button triggers the EXIT relay
(if the remote control is authorised for this car park control unit).
For 4-button remote controls:
Switch 4 in the OFF position: button I for the ENTRY relay and button II for the EXIT
relay (if the remote control is authorised for this car park control unit).
Switch 4 in the ON position: button III for the ENTRY relay and button III for the EXIT
relay (if the remote control is authorised for this car park control unit).
Setting the door unlock time
Switch 1 Switch 2 Switch 3 Unlock times of the "ENTRY" and "EXIT" relays
OFF OFF OFF Relay unlock times set to 05 seconds.
ON OFF OFF Relay unlock times set to 0.2 seconds.
OFF ON OFF Relay unlock times set to 01 second.
ON ON OFF Relay unlock times set to 03 seconds.
OFF OFF ON Relay unlock times set to 10 seconds.
ON OFF ON Relay unlock times set to 15 seconds.
OFF ON ON Relay unlock times set to 30 seconds.
ON ON ON Relay unlock times set to 60 seconds.
Channel authorised on the unit
Switch 4Buttons (I and II) or (III and IIII)
OFF Buttons I and II of the 4-button remote controls.
Left and right buttons of 2-button remote controls
ON Buttons III and IIII
The 2-button remote controls do not operate this mode
Note:
• Switch 5 is not used.
• Switch 6 resets the EEN-REC3 HF-RW receiver (See below).
Installation and user guide for the EEN-REC3-RW receiver
Page 4 / 6 V233 – 0012 – AA
Page 5
Reset procedure with switch No.6.
On completing this procedure, all Intratone remote controls will open the
accesses controlled by the receiver. "Access control" is no longer enabled. The
EEN-REC3-RW receiver will have returned to its unused state.
To proceed with the reset, do the following:
Switch switch no. 6 of the receiver (the LED lights up) and wait until the LED flashes.
Repeat this step twice until the LED flickers.
As soon as the LED flashes every 3 seconds, the reset has been completed and the receiver has
returned to its unused state.
Standards
The EEN-REC3-RW complies with the R&TTE Directive 1999/5/EC: electrical safety standard EN
60950(2000) applied, EMC standard EN 301 489-3 (2000) applied, radio standard EN 300 220-3
(2000) applied.
End of life product recycling:
The receiver and its accessories must not be disposed of with unsorted municipal waste, but
must follow the WEEE (Waste Electrical and Electronic Equipment) collection and
recycling channel.
Installation and user guide for the EEN-REC3-RW receiver
Page 5 / 6 V233 – 0012 – AA
Page 6
Sizes
Installation and user guide for the EEN-REC3-RW receiver
Page 6 / 6 V233 – 0012 – AA