The Intracode Visio call panel (ref.: EEN-PICV or as a Kit, EEN-KPV50-S / EENKPV1000-S) is a multifunctional call panel which transmits an image of the visitor to the
resident's telephone.
This call panel is available in a "Bronze" or "Zamak" coloured finish and is surface-mounted. It is configured using the following website: www.intratone.com in the
"management website" tab.
It must be connected to the following "real-time" central units:
2 to 4 doors (ref.: EEN-CEN12)
1 door (ref.: EEN- CIC12)
Ideal for fitting near an entrance gate; four opening methods are possible:
By using an authorised badge
By typing in a specific code
By calling a resident using the call panel, who then opens the door using a key on
his/her telephone
Using a "mobilekey"
Product description:
The Visio telephone intercom with scrolling name-display consists of:
A 12-key keypad and backlit LCD screen
Two scrolling keys and one call button
A proximity reader
A miniature camera for use in video calls
Built-in speech synthesiser: "Call in progress"; "Door open", etc.
"Wall-fixing" bracket
LCD display
Scrolling keys
Wall fixings
X 4
Keys on Keypad
Proximity reader
EN-V233 – 5003 – AB Installation and use of the EEN-PICV Intracode Visio call panel
Page 1 / 11
Page 2
CONTENTS
GENERAL POINTS-----------------------------------------1
CONTENTS---------------------------------------------------2
DIMENSIONS AND ASSEMBLY------------------------3
EN-V233 – 5003 – AB Installation and use of the EEN-PICV Intracode Visio call panel
Page 2 / 11
Page 3
A)
Sl
ide
Panel fixing
Hold the call
screwing it on
D
IMENSIONS
DIMENSIONS AND ASSEMBLY
B)
A
SSEMBLY
points
to
close
AND
panel against the
wall while
Do not trap cables when closing:
EN-V233 – 5003 – AB Installation and use of the EEN-PICV Intracode Visio call panel
risk of cutting them when tightened.
Page 3 / 11
Page 4
CABLING
CIC12
EEN-M3G
THE CENTRAL UNITS
THE CENTRAL UNITS
+
+
A+
Power supply: 12 / 24 V
–
2 to 4 A
MANDATORY
for
video
See EEN-CIC12 guide: V233 - 5002 - XX See EEN-CEN12 guide: V233-5001-XX
Not supplied
EEN-
+ - D+ D-
D+
D-
EEN-
M3G
A)
G
ENERAL POINTS
POWER SUPPLY: The central unit supplies power to the call panel via the + / - terminals.
CABLING: Twisted pairs – Diameter: 0.8 – Max. distance 100 metres.
Important note:
- The video function will only work if the call panel is installed with a 3G unit.
- If the call panel is installed with a PSTN line, only audio will work.
A-
V+ V-
EEN-CEN12
D+
DA+
A-
EEN-
M3G
+ - D+ D- A+ A-
V+ V-
AUDIO
EEN-PICVIV1
VIDEO
EEN-PICVIV1
B)
F
OR USE IN
Connect the following terminals up to the central unit:
Terminal Detail NB pair
+ / - Power supply
D-+ / D- Data 1
A+ / A- Audio 1
C)
F
OR USE IN
Also connect the following terminals up to the V+ / V- (VIDEO 1) terminals on the
3G unit:
Terminal Detail NB pair
V+ / V- Video 1
+ +
+
AUDIO
VIDEO
+
EEN-M3G
CALLS ONLY
CALLS
1
Twisted pairs
Twisted pair
or
or
recommended
EN-V233 – 5003 – AB Installation and use of the EEN-PICV Intracode Visio call panel
Page 4 / 11
Page 5
D)
Add an extension board
-
doors 3 and 4
Entrance
Building
S
CENARIO OF CONNECTING AN ENTRANCE GATE WITH THE 2 TYPES OF CENTRAL
UNITS
/ 2
/2
/ 4
/ 6
/ 6
/ 2
Connections in red refer to video (V+ / V-)
Connections in black refer to (+ / - and D+ / D- and A+ / A-)
E)
S
CENARIO OF CONNECTING AN ENTRANCE GATE PLUS A BUILDING
It is mandatory to use an EEN-CEN12 central unit with, in this example, an extension board.
Scenario:
"Audio and Video" calls from the entrance gate
Only "Audio" calls can be made from the building entrance.
/ 6
/ 6
/ 2
Extension board
/ 6
In this example, door 4 remains available
[41 49 and CRT]
Connections in red refer to video (V+ / V-)
Connections in black refer to (+ / - and D+ / D- and A+ / A-)
EN-V233 – 5003 – AB Installation and use of the EEN-PICV Intracode Visio call panel
Page 5 / 11
Page 6
EQUIPMENT CONFIGURATION
A)
G
ENERAL POINTS
INTRATONE call panels are mainly configured on the www.intratone.com website in
the "management website" tab. Nevertheless, some settings can be changed on-site:
- Configuration of the push button.
- Configuration of the door-opening time.
- Panel sound volume
B)
C
ONFIGURATION WITH A RESIDENTIAL CENTRAL UNIT,
(See the EEN-CEN12 central unit guide: V233-5001-XX)
With regard to the push button and of the door-opening time, see the "Door settings"
menu on the central unit.
With regard to the volume level, there are 2 options in the "Panel volume" menu:
- "Direct selection of volume":
Enter a value between 1 and 4 corresponding to the sound level.
- "Settings on the Panels":
This menu starts a 15-minute timer. During this time, you can move between the call
panel or panels connected to this central unit in order to adjust the sound level.
Step 1:
Type in the keypad
code: "12345678"
Step 2:
The call panel automatically
starts
"sound level adjustment"
which continues repeatedly.
sound level
adjustment
EEN-CEN12
Step 3 :
Validate
the chosen level
by pressing the
call button֠֠֠֠
on the call panel
This procedure is valid for 15 minutes per the timer. To exit from this procedure, wait until the
timer finishes or exit from the "Settings on the panels" menu.
EN-V233 – 5003 – AB Installation and use of the EEN-PICV Intracode Visio call panel
Page 6 / 11
Page 7
C)
"Save changes"
C
ONFIGURATION WITH AN INTRACODE
EEN-CIC12
CENTRAL UNIT
Exit from menus or
Return to scrolling menu
Go into menus or Make a
selection
Validation
Entering numbers
- How do I enter settings mode?
o Check that the welcome message is scrolling on the LCD screen
o Press the ֠֠֠֠ key until the "Enter password" menu appears.
o Type the serial number of the EEN-CIC12 central unit (7xxxxxx3).
o Validate with the ֠֠֠֠key. "You are in menu settings mode"
- To exit settings mode: o Press the arrow key several times until you return to the scrolling
message.
Menu options in settings mode:
Setting
the clock
|
|
|
|
|
|
Door
settings
|
|
|
Volume of
call panels
INTERNET Update
Request
Check fitting
|
|
Date: 28/01/13
Day: Monday
Time: 09:15
Type: winter
Accept remote
time: YES
Door settings
PB:NO Opening time:
05s
Direct selection
of the volume
Request an Update?
Test number:
֠
֠ or
֠֠
֠֠֠֠
Numeric keys for date entry
Key to select day
Numeric keys for time entry
Key to select summer/winter season
Key to select YES or NO
Key to select: NO or NC
Numeric keys for door-opening time entry
Key to Exit
Key ֠ to Validate
Enables direct input via the keypad of the
volume of the call panel connected
Key ֠ to Validate
Enables direct input via the keypad of the
telephone number to call for test purposes.
Start test procedure
Warning: the "door settings" menu will appear only if switches 4 / 5 / 6 on the EENCIC12 central unit are set to OFF.
EN-V233 – 5003 – AB Installation and use of the EEN-PICV Intracode Visio call panel
Page 7 / 11
Page 8
POST-FITTING CHECK
Before leaving the fitting, the following points should be checked:
A)
O
N THE PANEL
- Display shows the welcome message
- Check that the keypad keys (0, 1, 2 9, * and #) work.
Procedure:
o Press #; the display shows "Call number"
o The numeric keys must be displayed correctly
o Finish using the * key; the display should return to the welcome message.
- Check that the keypad keys are backlit.
B)
D
OOR CONNECTION
- Check door opening with the push button
- Check door opening using a badge
C)
C
ALLS
- Check the quality of a call by a visitor to a resident:
o Audio Call
o Video Call
- Check that, during the call, the resident can open the door by pressing the * key on
his/her telephone
(See Test Procedure in the central unit guide)
(See Test Procedure in the central unit guide)
D)
I
N THE CASE OF A FITTING WITH A 3G UNIT
If you use a 3G unit with your call panel, you can see the signal reception level for the unit
by pressing the 2 scrolling arrow keys
Depending on the situation, you will see:
"3G NET Lev 173" or "GSM NET Lev 173"
- NET : shows that the network has been found by the unit (3G or GSM)
- Lev : shows the level out of 30 (here,17 / 30) and the connection on a scale of 5
(here 3 / 5)
Press one of the arrow keys to exit from this menu.
E)
I
N THE CASE OF A FITTING WITH AN
Remember to make a note of the serial number (7XXXXXX3) of the central unit.
You will need this to go back into the installation and configure these settings on the
keypad outside.
֠
֠ on the display.
֠֠
EEN-CIC12
CENTRAL UNIT
EN-V233 – 5003 – AB Installation and use of the EEN-PICV Intracode Visio call panel
Page 8 / 11
Page 9
DIAGNOSIS IN THE EVENT OF A FAULT
PICVIV1 call panel
Install a 3G unit instead of a GSM
What is the fault?
Message on the display:
"Enter your code to open"
Message on the display:
"Enter a code or swipe a badge"
Keys and display
not backlit
Keys backlit but not
display (or the reverse)
The LCD screen does not
turn on
When swiping a badge, the
green LED on the reader
lights up but the door does not open.
If the call panel says " Call
in progress" but the
resident cannot hear the
visitor
The call panel says
"Unable to call" with no dial
tone
The resident cannot see
the visitor on his/her
telephone
Contact our technical support department (+33 (0)251 655 529)
What is causing the
fault?
Incorrect cabling between
the D+ and/or D- terminals
and the 3G unit
Incorrect cabling on the
D+ and/or D- terminals
- Incorrect cabling on the
+ and/or - terminals
- Equipment fault
Contact our technical support department
Incorrect cabling on the +
and/or - terminals
- Relay on the central unit
not working.
- Cable to the door
Incorrect cabling on the
A+ and/or A- terminals
Telephone network not
available
- Incorrect V+ / V- cabling
- Call panel not a Visio
panel
- The unit is not a 3G unit
- The telephone does not
support video
How to fix the fault!
- Check cabling between the 3G
block and the call panel: D+ / D-
- The display should show the
welcome message.
- Check cabling between the
central unit and the call panel: D+ / D-
- The display should show the
welcome message.
- Check cabling on the + and/or terminals
- Contact our technical support
department
Check cabling between the
central unit and the call panel: + /
-
- Check if relay sticks
- Check cabling between the
central unit and the door
Check A+ / A- cabling
Check cabling to the GSM unit
and LED levels
Check V+ / V- cabling
Install an EEN-
-PIC
EN-V233 – 5003 – AB Installation and use of the EEN-PICV Intracode Visio call panel
Page 9 / 11
Page 10
CERTIFICATE OF CONFORMITY
A)
S
TANDARDS
EC standards:
The central unit complies with the R&TTE Directive 1999/5/EC: electrical safety
standard EN 60950(2001) applied, EMC standard EN 301 489-3(2002) applied, radio
standard EN 300 330-2(2001) applied
The call panel complies with telephone network standards TS-103 021 and TR-103 000.
Cabling:
The cables connected to the central unit must not be placed in the vicinity of other
sources of electrical power (e.g. mains power supply).
Operating warranty:
The call panel is guaranteed for a temperature range of between -20°C and +70°C and
for relative humidity not exceeding 70%.
End of life product recycling:
The panel and its accessories must not be disposed of with unsorted municipal
waste but must be follow the WEEE (Waste Electrical and Electronic Equipment
Directive) collection and recycling channel.
EN-V233 – 5003 – AB Installation and use of the EEN-PICV Intracode Visio call panel
Page 10 / 11
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.