Intratone EEN-PAD User Manual

Fitting and connecting the panel to a central unit
Scr
Fitting and connecting the panel to a central unit
Fitting and connecting the panel to a central unitFitting and connecting the panel to a central unit
Residential
Important notes
EC standards:
- The panel unit complies with the R&TTE Directive 1999/5/EC: electrical safety standard
EN 60950(2001)applied, EMC standard EN 301 489-3 (2002) applied, radio standard EN
300 330-2 (2001) applied.
- The panel complies with the telephone network standards TS-103 021 and TR-103 000.
Cabling:
- -The cables connected to the central unit must not be placed in the vicinity of other sources of
electrical power (e.g. mains power supply).
Operating warranty
- The panel is guaranteed to operate within a temperature range of between -20°C and +70°C in
which relative humidity does not exceed 70%.
End of life product recycling:
The panel and its accessories must not be disposed of with unsorted municipal waste, but must follow the WEEE (Waste Electrical and Electronic Equipment) collection and recycling channel.
Fit the tip to a hex shaped tool or to a reversible screwdriver.
Unscrew the panel's 6 screws
Remove the front and place it so that you can read the terminal block numbers.
Fit the box in its built-in wall mounting.
Note: Cable pass throughs in the box will allow you to pass the cables.
Wire the panel to one of the central unit's terminal's as shown below.
Warning: You cannot connect two panels to the same terminal on the central unit.
Screw the front of the panel back onto the box.
Connecting a name scrolling panel
to the Intratone Residential central unit
Page 1 / 2 V231 – 0027 – AB
Cabling of a panel connected to connector 2
+
1 2 3 4 5 6 7 8 9 111
11 13 14 15 16 17 18 19
C R T
12
1 2 3 4 5 6 7 8 9 111
21 23 24 25 26 27 28 29
C R T
22
Connector 1
11 to 19 and CRT
Length - Diameter
Max 100 m using 0.6mm
Max 200m using 0.9mm
Do not connect 2 panels in parallel.
With a PSTN line, connector no.1 can be
connected to a panel.
With a GSM unit, connector no.1 cannot
be connected to a panel.
Size of the built-in wall box
21 to 29 and CRT
Connector 2
Central unit terminal
blocks
Panel card's terminal
blocks
Connecting a name scrolling panel
to the Intratone Residential central unit
Page 2 / 2 V231 – 0027 – AB