Connection and fitting guide for the GPRS module 
                 Residential
CE standards: 
-  The GPRS unit complies with EC directive R&TTE 1999/5/CE: electrical safety standard 
used: EN 60950(2001), EMC standard applied: EN 301 489-3(2002), radio standard applied: 
EN 300 330-2(2001). 
-  The GPRS module complies with GSM (Radio spectrum) standards EN 301 511 and 3GPP 
51.010-1. 
-  The GPRS module complies with EMC standards EN 301 489-1 and EN 301.489-7 
Cabling: 
-  The cables connected to the central unit must not be placed in the vicinity of other sources of 
electrical power (e.g. mains power supply). 
-  3-pair twisted cables 0.5mm minimum. 
Operating warranty: 
-  The GPRS unit is guaranteed for a temperature range between -20°C and +70°C and for relative 
humidity not exceeding 70%. 
-  The flap on the unit must be turned down in order to protect the block from rainwater ingress. 
End-of-life product recycling: 
The receiver and its accessories must not be disposed of with unsorted municipal waste, but 
must follow the WEEE (Waste Electrical and Electronic Equipment) collection and recycling 
channel.
The LEDs on the GPRS 
module display the 
reception quality of the 
surrounding GPRS network 
signal: 
"The more LEDs lit up, the 
better the signal". 
Optimum performance is 
achieved with at least 
3 LEDs lit up. 
 Poor reception can lead to an inability to make calls or perform 
updates. We therefore advise that you conduct 
to find the location with the best reception (the GPRS module can 
be installed 100m away). 
 The GPRS module can be installed outside as well as inside. 
 N
EVER PUT THE UNIT INSIDE A METAL BOX
! 
Connection guide for the Intratone Residential EEN-MGPRS unit 
Page 1 / 2    EN-V231 – 0038 – BA 
 

1 2 3 4 5 6 7 8 9 10 11 12
1 2 3 4 5 6 7 8 9 10 11 12
The GPRS module is exclusively for Data (no 
voice). It does not therefore work with a call panel! 
Connecting the GPRS module to an Intratone Residential central 
unit: 
Always connect the GPRS module to terminals 11 to 14 
Connector 1 on the central unit 
11 to 19 and CRT 
11 13 14 15 16 17 18 19
12
+ - D+ D-
Maximum cable distance/diameter: 
- 200m using 0.8mm 
- 100m using 0.5mm 
Connector 2 on the central unit 
21 to 29 and CRT 
21 23 24 25 26 27 28 29
22
GPRS unit connector 
EEN-CEN-12 
EEN-MGPRS 
Connecting the GPRS module to an IntraCode central unit: 
Connector on the IntraCode 
central unit 
+ - D+ D-
Maximum cable distance/diameter: 
- 200m using 0.8mm 
- 100m using 0.5mm. 
GPRS Module connector 
EEN-MGPRS 
Warning: The "Alert" terminals on the GPRS module are operational only if 
you connect the GPRS module to a central unit.  
Only the alert terminals on the central units may be configured in this case. 
Plug-in terminals on the GPRS module 
1. Connect the 6 wires such that 
TERMINALS POINT DOWNWARDS
2. Plug the terminals into the 6 pico-terminals on the module. 
3. Turn the installation on and check the status of the LEDs 
on the module. 
THE SCREWS ON THE PLUG-IN 
. 
+ -
D+ D-
Connection guide for the Intratone Residential EEN-MGPRS unit 
Page 2 / 2    EN-V231 – 0038 – BA