Intratone EEN-CR Installation Manual

1
2
3
Switch 1 Switch 2
area
D+ D- A- A+
2
3
4
1
De
lay potentiometer
8
9
7
R
T
C
To ancillary
5
6
To ancillary
D+ D- C R T
2
3
4
1
Delay potentiometer
8
9
7
R
T
C
lary
1 2 3 4 5 6
5
6
o ancillary
Installation and user guide for an auxiliary 1,
2, 3 or 4-door card of the Intratone range
Presentation of the EEN-CR auxiliary door card
This card opens auxiliary relays that will control a door or a light etc. Two potentiometers control the opening of the auxiliary door. The first potentiometer sets
the delay before opening, the second the door unlock time. Two switches indicate the auxiliary door's address: 1 / 2 / 3 or 4. The third switch indicates
the type of door pushbutton (NO/NC). Finally, this card is fitted with a door entry pushbutton.
Power supply 12 to 24 VDC / 50 mA Max cabling distance 300 m in 0.80mm Delay before opening from 0 to 60 sec.
Door unlock time from 0.2 to 60 sec.
0.2 sec
5 sec
area
Potentiometer
Installation and user guide for an auxiliary 1, 2, 3 or 4-door card of the Intratone range Page 1 / 2 V233 - 0006 - AA
Technical specifications
(approx)
Switch 3 Button type
(approx)
Door No.
OFF OFF 1 st
ON OFF 2 nd
OFF ON 3 rd
ON ON 4 th
OFF Normally Open
ON Normally Closed
Installation with an IntraCode central unit
Intracode mini central unit
Relay main
door
Unlock time potentiometer
- +
Ancillary card
Proximity
proximity
reader
To other ancillary cards
To main
door
To ancil door
Relay ancillary door
T door pushbutton
Installation with independent GSM unit (without central
unit)
Unlock time potentiometer
GSM edge module
Ancillary card
To other ancillary
Proximity reader (OPTIONAL)
Installation and user guide for an auxiliary 1, 2, 3 or 4-door card of the Intratone range Page 2 / 2 V233 - 0006 - AA
cards
door
Relay ancillary door
- +
door pushbutton
Loading...