Intratone EEN-BOXECO HF User Manual

D+
+
S
V. P.
ANT
C1
T1
C2
T2
1
2
     
D+
+
W
IRING DIAGRAM
EEN-MGPRS
12/24V DC - 2AMP
(NOT SUPPLIED)
As close as possible to the
EEN-REC3
EEN-REC3
D-
-
Alert
Cabling
E
D-
-
A
Max 100m from power supply using 0.5 dia. twisted cable Max 200m from power supply using 0.8 dia. twisted cable
See below
V.P.: Vehicle Present E: Entry - S: Exit A: Alert ANT: Aerial - 1: Core / 2: Braid
Relay 1: C1 / T1 – Relay 2: C2 / T2
To vehicle
entry sensor
To vehicle exit sensor
NEVER PUT THE EEN-MGPRS BLOCK OR THE RF RECEIVER IN A METAL BOX
The LEDs on the EEN-MGPRS block display the reception quality of the nearby GPRS network signal:
"The more LEDs are ON, the better the signal". For optimum performance, ensure that you have 3 LEDs
ON.
DO NOT FORGET TO NOTE THE EEN-MGPRS CONTRACT No. AND RELATED ACCESS POINT.
You will need this to create your equipment on www.intratone.com in the "management Website" link
EEN-BOXECO – HF
: Installation Guide
Page 1 / 2 EN-V231-0098-BA
T1 C2 T2
2 1
Woven
wire
2 1
CARPARK DOOR
2 Relays (Entry / Exit) 2A
at 24V
C T
C1
Voltage free contact to
Control a mechanism:
entry exit
C T
S1 S2 S3 Description
OFF OFF OFF No anti-passback function.
ON OFF OFF Anti-passback set to 05 minutes.
OFF ON OFF Anti-passback set to 10 minutes.
ON ON OFF Anti-passback set to 15 minutes.
OFF OFF ON Anti-passback set to 30 minutes.
ON OFF ON Anti-passback set to 45 minutes.
OFF ON ON Anti-passback set to 60 minutes.
ON ON ON Anti-passback permanently on.
S4 S5 Description
OFF OFF Loop Normally Closed (LC) or no loop.
S
WITCH DESCRIPTION
ANTENNA
With the
FACTORY FITTED
ANT.
ON ON Loop Normally Open (LO)
Switch no. 6: Always set to OFF.
Any change to this switch resets the rolling codes and anti-passback
IMPORTANT:
Installation of the varistors supplied with the central unit ensures the system's proper functioning and longevity.
1. The varistor must be fitted as close as possible to the electric lock or the magnet lock.
2. Open access times should be avoided in the case of doors fitted with electric locks!
3. The varistor is 12V.
IF YOU INSTALL SEVERAL POWER CABLES, ENSURE THAT GROUNDS (-) ARE ALL CONNECTED.
The complete pack for managing single-door access with
1 868Mhz HF Receiver (EEN-REC3) 1 (EEN-MGPRS-DATA) module.
With 868 MHz aerial
NOT SUPPLIED
ANT
Core
EEN-BOXECO – HF
: Installation Guide
Page 2 / 2 EN-V231-0098-BA
Loading...