![](/html/6b/6b93/6b9330cfaa0c7ed096b5e1a051c1dde1773e7abfa67f898a74def89f1df9a437/bg1.png)
User guide
For the EEN-BOXECO-HF kit
General points
The complete pack for car-park access control consists of a waterproof RF receiver
(EEN-REC3) with a 868Mhz RF antenna and a GPRS module (EEN-MGPRS)
Unlimited updates and event logging for a period of ten years after initial installation of subsequently
rechargeable equipment is available to you.
Update via
the Internet
EEN-MGPRS
EEN-REC3
www.intratone.com in the
"management website" tab
• DO NOT USE OTHER USER AND INSTALLATION GUIDES
Principle of how the EEN-REC3 receiver works
General points :
• The EEN-REC3 receiver enables control of two car park access points: "ENTRY" and "EXIT" and works
with the 2-and 4-channel 868MHz RF remote controls.
• The GPRS module enables the equipment to be programmed via the website: www.intratone.com
• When controlling the 2 accesses, the anti-passback function is available using the switch settings.
• It is waterproof and can be attached to an outside wall.
The RF 868 remote control opens two doors, "ENTRY" and "EXIT":
These 2 doors are controlled via 2 "CT" relays fitted to the receiver card.
Pressing a button on the remote control will activate one of these two "ENTRY" or "EXIT" relays:
Vehicle Detection:
Activating each "ENTRY" / "EXIT" relay may depend on the use of vehicle detection loops. These loops can
be configured separately as "Normally Closed (NC)" or "Normally Open (NO)" by means of switches no's 4
and 5 in the receiver (see section on switches and led below).
Anti-Passback (only if enabled on the website and on the EEN-REC3 receiver):
The EEN-REC3 receiver can also manage anti-passback conditions (obligation to exit before re-entering) on
remote controls set to anti-passback on the site. This handling is set using switches 1, 2 and 3 (see switches
and LED section below).
Switch no. 6: For correct operation, it must always be set to OFF.
Page 1 / 4 User guide for the EEN-BOXECO-HF EN-V232-0076-BA
![](/html/6b/6b93/6b9330cfaa0c7ed096b5e1a051c1dde1773e7abfa67f898a74def89f1df9a437/bg2.png)
Anti-passback operation
Anti-passback controls the receiver's 2 ENTRY and EXIT doors to prohibit successive entries (entries by
several vehicles using the same remote control). The resident must therefore have left via the EXIT door
before again being allowed access to the car park via the ENTRY door.
The anti-passback function works by setting an anti-passback time during which any new attempt to gain
access via the ENTRY door is systematically denied. Access via the ENTRY door will be authorised again,
either after this time has expired, or once the resident has left via the EXIT door.
The anti-passback function is only activated with the combined use of:
- A EEN-REC3 receiver;
- A GPRS module
- Vehicle detection loops on ENTRY and EXIT.
And it only works with remote controls to which anti-passback apply (see Website).
This function does not concern any remote controls not programmed to work with the anti-passback function.
Note: The anti-passback is reset each time it is powered on.
Switches and LED
• Switches 1, 2 and 3 define the time of the anti-passback function (+ or - 2 minutes):
S1 S2 S3 Meaning
OFF OFF OFF No anti-passback handling.
ON OFF OFF Anti-passback set to 05 minutes.
OFF ON OFF Anti-passback set to 10 minutes.
ON ON OFF Anti-passback set to 15 minutes.
OFF OFF ON Anti-passback set to 30 minutes.
ON OFF ON Anti-passback set to 45 minutes.
OFF ON ON Anti-passback set to 60 minutes.
ON ON ON Permanent anti-passback.
• Switches 4 and 5 define the operation of the vehicle detection loops :
S4 S5 Meaning
OFF OFF Loop Normally Closed (LC) or no loop installed.
ON ON Loop Normally Open (LO)
• Switch no. 6: It must always be set to OFF.
Any change to this switch resets the rolling codes and anti-passback.
• LED: The LED shows the operating status as follows:
Status Meaning
Flashing for 1 to 2 sec Power on or
after changing switch 6: Deletion of anti-passback and rolling code.
Permanently OFF The receiver has no power supply: Check the connection to the receiver's + and -
terminals.
Flickering The central unit is not connected correctly to the receiver's D + and D-
terminals.
Permanently ON Correct communication with the central unit: Diagnosis displays "RF".
Goes off for 1 second Correct reception of the RF emission by a 868 MHz remote control.
Page 2 / 4 User guide for the EEN-BOXECO-HF EN-V232-0076-BA