Installation and user guide for an auxiliary 1, 2, 3 or 4-door 
card of the Intratone range 
Presentation of the EEN-CR auxiliary door card 
This card opens auxiliary relays that will control a door or a light etc. 
Two potentiometers control the opening of the auxiliary door. The first potentiometer sets the 
delay before opening, the second the door unlock time. 
Two switches indicate the auxiliary door's address: 1 / 2 / 3 or 4. The third switch indicates the 
type of door pushbutton (NO/NC). 
Finally, this card is fitted with a door entry pushbutton. 
Power supply  12 to 24 VDC / 50 mA 
Max cabling distance  300 m in 0.80mm 
Delay before opening   from 0 to 60 sec. 
Door unlock time   from 0.2 to 60 sec. 
0.2 sec 
Technical specifications 
(approx) 
(approx) 
Installation with an IntraCode central unit 
Intracode mini central unit 
Relay main 
door 
Unlock time potentiometer 
 -     +
Ancillary 
card 
Proximity 
proximity 
reader 
To other 
ancillary 
cards 
To main 
door 
To ancillary 
door 
Relay  
ancillary  
door 
To ancillary 
door 
pushbutton 
Installation with independent GSM unit (without central 
unit) 
Unlock time potentiometer 
GSM edge module 
 -     +
5 sec 
area 
OFF  OFF  1 st 
ON  OFF  2 nd 
OFF  ON  3 rd 
Potentiometer 
ON  ON  4 th 
Switch 3  Button type 
OFF  Normally Open 
ON  Normally Closed 
Installation and user guide for an auxiliary 1, 2, 3 or 4-door card of the Intratone range 
Page 1 / 2                                                                  EN-V233 - 0006 - AA
Door No. 
Ancillary 
card 
Proximity reader 
(OPTIONAL) 
To other 
ancillary 
cards 
door 
Relay  
ancillary  
door 
To ancillary 
door 
pushbutton 
Installation and user guide for an auxiliary 1, 2, 3 or 4-door card of the Intratone range  
Page 2 / 2                                                                                                                                   EN-V233 - 0006 - AA