Disposal of old electrical and electronic equipment (applicable through the
or on its packaging, indicates that electrical and electronic equipment may not be
By ensuring the correct disposal of this product, you will help prevent potential
By recycling, reusing and other forms of recovery of old electrical and electronic
equipment you are making an important contribution to the conservation of natural
purchased this product.
ηλεκτρικών και ηλεκτρονικών συσκευών βοηθούν στη διαφύλαξη των φυσικών πόρων
(www.electrocycle.gr).
European Union and other European countries with separate waste collection
systems).
This symbol, found on this product and any of it s parts or on it s ope r ating inst ructi ons
disposed of as unsorted municipal waste. Instead, this prod uct should be handed over
to applicable collection points for the recycling of electrical and electronic equipment.
negative consequences to the environment and human heal th, which could other wise
be caused by inappropriate disposal of this product .
resources and to the protection of the environment.
For more information about the recycling of thi s product, please contact your local
municipal authorities, municipal waste dispo sal service or the store where you
StreetNode 6250 PTP with Embedded Node Manager
WebGUI Commissioning Manual - Ed1.1
•
Απόρριψη παλαιών ηλεκτρικών και ηλεκτρονικών συσκευών (ισχύει στην
Ευρωπαϊκή Ένωση και άλλες Ευρωπαϊκές χώρες με συστήματα χωριστής
συλλογής απορριμμάτων).
Το σύμβολο αυτό, που απεικονίζεται πάνω στο προϊόν και σε τυχόν εξαρτήματα του
ή στο εγχειρίδιο οδηγιών του ή στη συσκευασία του, δείχνει ότι οι ηλεκτρικές και
ηλεκτρονικές συσκευές, μετά το πέρας της λειτουργίας τους, δεν θα πρέπει να
απορρίπτονται μαζί με τα αστικά απόβλητα. Αντίθετα θα πρέπει να παραδίδονται σε
κατάλληλα σημεία συλλογής για την ανακύκλωση των ηλεκτρικών και ηλεκτρονικών
συσκευών.
Διασφαλίζοντας τη σωστή απόρριψη αυτού του προϊόντος, συνεισφέρετε στην
πρόληψη πιθανών αρνητικών συνεπειών στο περιβάλλον και την ανθρώπινη υγεία,
οι οποίες θα μπορούσαν να προκληθούν από την μη ενδεδειγμένη απόρριψη του
προϊόντος.
Η ανακύκλωση, επαναχρησιμοποίηση και άλλες μορφές αξιοποίησης των παλαιών
και στην προστασία του περιβάλλοντος.
Για περισσότερες πληροφορίες σχετικά την ανακύκλωση αυτού του προϊόντος,
παρακαλούμε επικοινωνήστε με τις τοπικές δημοτικές αρχές, την υπηρεσία
αποκομιδής αστικών αποβλήτων ή το κατάστημα από το οποίο αγοράσατε το
συγκεκριμένο προϊόν.
Για περισσότερες πληροφορίες, μπορείτε να επικοινωνείτε με το Συλλογικό Σύστημα
Εναλλακτικής Διαχείρισης Αποβλήτων Ηλεκτρικού και Ηλεκτρονικού Εξοπλισμού
“Ανακύκλωση Συσκευών Α.Ε.”
•
-III-
StreetNode 6250 PTP with Embedded Node Manager
on page 12.
Standards of Complianceστην σελιδα 12.
WebGUI Commissioning Manual - Ed1.1
Declaration of Conformity
Hereby, Intracom S.A. Telecom Solutions declares that the product
StreetNode
6250 PTP is CE marked, complying with the requirements of
the R&TTE Directive 1999/5/EC , EMC Directive 2004/108/ΕC, LVD
Directive 2006/95/ΕC, ΕCO Design Directive 2009/125/EU & with the
requirements of the RoHS Directive 2011/65/ΕU.
The product complies to all relevant FCC regulations.
For further information, please refer to Appendix A: Standards of Compliance
Δήλωση Συμμόρφωσης
•
Με την παρούσα, η Intracom Α.Ε. Τηλεπικοινωνιακών Λύσεων δηλώνει ότι
το προϊόν
προς τις απαιτήσεις και τις λοιπές διατάξεις των οδηγιών R&TTE 1999/5/EC,
EMC 2004/108/ΕC, LVD 2006/95/ΕC, ΕCO Design 2009/125/EU καθώς και
με τις απαιτήσεις της οδηγίας RoHS 2011/65/EU.
Το προϊόν συμμορφώνεται σε όλους τους σχετικούς κανονισμούς της
Ομοσπονδιακής Επιτροπής Τηλεπικοινωνίων της Ηνωμένων Πολιτειών
Αμερικής (FCC).
Για περισσότερες πληροφορίες παρακαλώ δείτε το παράρτημα
•
StreetNode 6250 PTP φέρειτηνσήμανση CE συμμορφούμενο
Appendix A:
•
-IV-
Radiation Safety
Introduction
Regulations
Any radio equipment is emitting Radio Frequency (RF) radiation through its
antenna.
In the StreetNode
inside the unit’s enclosure.
It is important to follow any local, national or international regulation during
installation and operation of the radio equipment to minimize radiation
hazards.
Many countries have issued and follow their own RF safety regulations,
while many others have adopted international regulations, standards or
guidelines.
In Europe, some countries follow the recommendations included in the
1999/519/EC directive, which is based on the guidelines document published
by the International Commission on Non-Ionizing Radiation Protection
(ICNIRP).
The above mentioned European directive provides the reference levels
(limits) for assessment of the human exposure to electromagnetic fields
based on health effects. Other regulators may define different reference
levels.
The European Union and U.S. regulator (FCC) Reference Levels for the
microwave frequencies are given below:
Regulation
1999/519/EC 2.0 – 300 61 V/m 10 W/m2 General Public
FCC OET 65 1.5 – 100 - 1 mW/cm2
FCC OET 65 1.5 – 100 - 5 mW/cm2
StreetNode 6250 PTP with Embedded Node Manager
WebGUI Commissioning Manual - Ed1.1
TM
6250 PTP radio, the antenna is integrated and located
As a general rule, it is expected that the highest level of emission would be
at the antenna emission lobe maximum, in direct line-of-sight condition and
in the close vicinity of the antenna.
Additional requirements for the installation of the StreetNode
radio shall be as follows:
The radio should be located in such a way to prevent the public from
•
accessing the area where the RF radiation exceeds the regulation limits.
For this, a compliance boundary is determined, based on its radio
characteristics. Outside this area, the RF radiation levels are below the
reference levels (limits).
Operation and maintenance personnel, which have to work within the RF
•
radiation compliance boundary area, should be informed about the source
of radiation and should have the capability to power off the radio
equipment before entering the compliance boundary area.
The compliance boundary area should be defined by a relevant warning
•
sign or physical barrier.
TM
6250 PTP
Continued on next page
-VI-
StreetNode 6250 PTP with Embedded Node Manager
Parameter
Value
Compliance Boundary (General Public)
0,64
m
RF exposure compliance boundary studies / reports are available
upon request.
1999/519/EC, COUNCIL RECOMMENDATION of 12 July 1999
on the limitation of exposure of the general public to
ELECTRIC, MAGNETIC, AND ELECTROMAGNETIC FIELDS
Radiation Safety, Continued
Compliance
boundary
definition
The Compliance Boundary Definition for StreetNodeΤΜ 6250 PTP is shown to
the following table below:
WebGUI Commissioning Manual - Ed1.1
Max EIRP 40,0
Max EIRP (worst case conditions) ~47,0
Power Flux Density Limit (General Public) 10,0
Power Flux Density Limit (Occupational) 50,0
Compliance Boundary (Occupational) 0,29
dBm
dBm
W/m
W/m
m
10,0
~50,00
2
2
W
W
The above calculations are based on information available at the
time of issue of the current document.
References
-
electromagnetic fields (0 Hz to 300 GHz).
- OET Bulletin 65, Evaluating Compliance with FCC Guidelines for
Human Exposure to Radiofrequency Electromagnetic Fields,
Edition 97-01, August 1997.
- GUIDELINES FOR LIMITING EXPOSURE TO TIME-VARYING (UP TO 300 GHz), International Commission on Non-Ionizing
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference
that may cause undesired operation.
FCC Part 15.21 Statement: Information to the User
Changes or modifications made to this equipment, not expressly approved
by the party responsible for compliance, could void the user's authority to
operate the equipment.
FCC Part 15.105 Statement: Information to the User
This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to part 15 of the FCC rules.
These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy
and, if not installed and used in accordance with the instruction manual, may
cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the
interference at his own.
Integrated Bluetooth Module FCC ID
The unit contains a certified Bluetooth Module.
The end user has no access to this module.
The FCC ID of the internal Bluetooth module can be found after the phrase
“Contains FCC ID” on the label displaying the FCC IDs related to the unit.
This document provides detailed startup, commissioning and
operation instructions for the following equipment:
StreetNode 6250 PTP with embedded Node
•
Manager (NM) software.
The procedures described in this manual can be carried out by
any technician with basic skills in computer-aided commissioning
of outdoor electrical equipment.
Before starting any commissioning works please refer to
WebUI Commissioning Manual – Edition 1.1
3
StreetNode 6250 PTP with Embedded Node Manager
WebUI Commissioning Manual – Edition 1.1
Reference manuals item 2 on page 2.
Safety Precautions
Before starting any commissioning works please refer to
4
StreetNode 6250 PTP with Embedded Node Manager
WebUI Commissioning Manual – Edition 1.1
Hardware / Software
Description
Hardware & Software Requirements
Laptop with the following
minimum requirements:
th
CPU x86, 9
•
generation
(Intel Core 2 or AMD
ATHLON II Neo).
250 MB HDD.
•
512 MB RAM.
•
Network interface card.
•
Windows XP or later
•
version.
Ethernet cable
(CAT5e, straight-through).
5
StreetNode 6250 PTP with Embedded Node Manager
WebUI Commissioning Manual – Edition 1.1
Laptop
StreetNode
GbE
Ethernet
cable
(Power supply cabling is not shown for simplicity).
Connecting the Laptop
Where to
connect
The laptop can be connected directly to the StreetNodeTM 6250
PTP node, in any of its available traffic interfaces located
underside:
Gigabit Ethernet 1 (electrical, RJ-45).
•
Gigabit Ethernet 2 (electrical, RJ-45).
•
Gigabit Ethernet 3 (SFP).
•
Procedure
By using an appropriate equipment lifter vehicle (for elevating to
the installation position) and an Ethernet cable, connect the laptop
to one of the Ethernet / SFP ports at the bottom of the
StreetNode
If an Ethernet cable is already pre-installed, unplug it and connect
the laptop with another Ethernet cable. Restore everything as
found after finishing with the startup and commissioning.
6
TM
6250 PTP box.
StreetNode 6250 PTP with Embedded Node Manager
Assumptions
For reader’s convenience, we make the following assumptions
regarding the startup and commissioning procedure:
WebUI Commissioning Manual – Edition 1.1
TM
•
Site A
– the location of the StreetNode
6250 PTP node
that is closest to customer’s PoP (Point of Presence) and
is the node that will be installed first.
•
Site B
– the location of the StreetNodeTM 6250 PTP node
that is farther away from customer’s PoP (with respect to
) and is the node that will be installed second.
is meant the StreetNode
TM
6250 PTP unit that the
•
Site A
“Local”
commissioner is directly connected to (using a laptop).
TM
“Remote”
•
is meant the StreetNode
6250 unit that the
commissioner is connected to remotely and by using a
laptop connected to
The StreetNode
“local”
TM
6250 PTP “Local” node, located closest to
unit.
network synchronization source, will retrieve synchronization
from its Gigabit Ethernet ports and will transport it to the next
TM
terminating StreetNode
6250 PTP node over the air
medium.
The StreetNode
TM
6250 PTP “Remote” node will retrieve
network synchronization from its modem port and will
transport it (to the next terminating StreetNode
TM
6250 PTP
node) through its Gigabit Ethernet ports.
7
StreetNode 6250 PTP with Embedded Node Manager
WebUI Commissioning Manual – Edition 1.1
Node Manager for StreetNodeTM 6250 PTP.
Startup & Commissioning Procedure
Introduction
Precautions
On the following pages, an overview of the startup and
commissioning procedure is provided.
For detailed instructions on the included steps, the reader is
prompted to the respective section of the Reference Manual of the
You must configure the modem operation of all
StreetNode
TM
6250 PTP nodes (participating in the
link) so that:
Both nodes are configured to have the same
•
channel bandwidth / size and adaptive mode.
If MAC header suppression is enabled for
•
one node, the same must be done for the
other node(s) of the link.
Continued on next page
8
StreetNode 6250 PTP with Embedded Node Manager
WebUI Commissioning Manual – Edition 1.1
Step
Action
e.
Startup & Commissioning Procedure, Continued
Overview
The commissioning of a StreetNodeTM 6250 PTP unit will be carried as follows:
Details Refer to
Visit site A. Install StreetNodeTM 6250 PTP, point it
1
coarsely toward site B and power it up.
Configure
2
management.
In case the (default) VLAN with id=1 is
to be used, then set:
Acceptable Frame Type = Tagged
and Untagged (modem configuration).
If a different VLAN is to be used, no
such action is required.
EΝ 60950-1:2006 +A11:2009 +A1:2010 +A12: 2011
EN 60950-22: 2006
EN 50385 : 2002
EN 60215:1989 +A1:1992 +A2:1994
IEC/UL/CSA 60950-1
IEC/UL/CSA 60950-22
RoHS : EN 50581 :2012
Eco Design: CR (EC) No. 278/2009
Environmental:
ETSI EN 300019-2-4 V2.2.2, Class 4.1 / (Mechanical 4M5)
(Operation)
(Within Spec Operating temperatures: -33°C to +55°C,
Operational at -50°C).
IEC 60529, Class IP67 (Protection against dust and water)
ETSI EN 300 019-2-2 v2.1.2, Class 2.3 (Transportation)
ETSI EN 300 019-2-1 v2.1.2, Class 1.2 (Storage)
12
StreetNode 6250 PTP with Embedded Node Manager
WebUI Commissioning Manual – Edition 1.1
BW
CBS
Committed Burst Size
CIR
CoS
CRC
DSCP
FDB
L2CP
LDPC
LED
Light Emitting Diode
PDU
PoP
PtP (PTP)
Point-to-Point
QAM
QL
QoS
Quality of Service
RAI
RMON
RRC
Radio Resource Control
RSSI
SNMP
SNR
S-VLAN
TCM
Glossary
Bandwidth
Committed Information Rate
CLI
DCN
IP
Command Line Interface
Class of Service
Cyclic Redundancy Check
Data Communication Network
Differentiated Services Code Point
Forwarding Database
Internet Protocol
Layer 2 Control Processing
Low-Density Parity Check
RSTP
SP
VLAN
Protocol Data Unit
Point of Presence
Quadrature Amplitude Modulation
Quality Level
Remote Alarm Indication
Remote network MONitoring
Received Signal Strength Indicator
Rapid Spanning Tree Protocol
Simple Network Management Protocol
Signal-to-Noise Ratio
Strict Priority
Service VLAN
Three Color Marking
Virtual Local Area Network
13
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.