(131) MODEL CS8110 SALTWATER SYSTEM ENGLISH 7.5” X 10.3” PANTONE 295U 07/28/2010
English
IMPORTANT
SAFETY RULES
Read, understand, and follow all
instructions carefully before
installing and using this product.
Krystal Clear
Saltwater System
Model CS8110
131
®
OOWWNNEERR’’SSMMAANNUUAALL
For illustrative purposes only.
Don’t forget to try these other fine Intex products: pools, pool accessories,
inflatable pools and in-home toys, airbeds and boats available at fine
retailers or visit our website.
IIMMPPOORRTTAANNTT!!
DO NOT RETURN PRODUCT TO STORE
To purchase parts and accessories or to obtain non-technical assistance,
Visit www.intexcorp.com
For technical assistance and missing parts call us toll-free (for U.S. and Canadian Residents):
1-800-234-6839
Monday through Friday, 8:30am to 5:00pm Pacific Time
131**-R0-1108
(131) MODEL CS8110 SALTWATER SYSTEM ENGLISH 7.5” X 10.3” PANTONE 295U 07/28/2010
Intex Service Center Locations........................................... 29
TTAABBLLEEOOFFCCOONNTTEENNTTSS
SAVE THESE INSTRUCTIONS
Page 2
(131) MODEL CS8110 SALTWATER SYSTEM ENGLISH 7.5” X 10.3” PANTONE 295U 07/28/2010
English
IMPORTANT SAFETY RULES
Read, Understand and Follow All Instructions Carefully Before Installing and Using this Product.
READ AND FOLLOW ALL INSTRUCTIONS
WARNING
To reduce the risk of injury, do not permit children to use this product. Always
•
supervise children and those with disabilities.
• Children must stay away from this product and all electrical cords.
• Assembly and disassembly by adults only.
• Risk of electric shock. Connect this product only to a grounding type receptacle
protected by a ground-fault circuit interrupter (GFCI). Contact a qualified electrician
if you cannot verify that the receptacle is protected by a GFCI.
• Always unplug this product from the electrical outlet before removing, cleaning,
servicing or making any adjustment to the product.
• Do not bury the electrical cord. Locate the cord where it will not be damaged by
lawn mowers, hedge trimmers and other equipment.
• To reduce the risk of electric shock, the supply cord cannot be replaced. If the cord
is damaged, the appliance should be replaced immediately.
• To reduce the risk of electric shock, do not use extension cords, timers, plug
adaptors or converter plugs to connect unit to electric supply; provide a properly
located outlet.
• Do not attempt to plug in or unplug this product while standing in water or when
your hands are wet.
• Do not use an appliance leakage current interrupter (ALCI) in place of a GFCI
since the ALCI will not protect people.
• Position this product away from the pool, so as to prevent children from climbing on
it and accessing the pool.
• Do not operate this product when the pool is occupied.
• This product is intended to be used only for the purposes described in the manual!
131
SSAAFFEETTYYRRUULLEESS
FAILURE TO FOLLOW THESE WARNINGS MAY RESULT IN
PROPERTY DAMAGE, ELECTRIC SHOCK, ENTANGLEMENT OR
OTHER SERIOUS INJURY OR DEATH.
CAUTION
This product is for use with storable pools only. Do not use with
permanently-installed pools. A storable pool is constructed so that it is capable of
being readily disassembled for storage and reassembled to its original integrity. A
permanently-installed pool is constructed in or on the ground or in a building such
that it cannot be readily disassembled for storage.
These product warnings, instructions and safety rules provided with the product represent
some common risks of water recreation devices and do not cover all instances of risk and
danger. Please use common sense and good judgement when enjoying any water activity.
For portable Above-Ground-Pools only
SAVE THESE INSTRUCTIONS
Page 3
(131) MODEL CS8110 SALTWATER SYSTEM ENGLISH 7.5” X 10.3” PANTONE 295U 07/28/2010
English
131
PARTS LIST
1
* Optional
4
2
5
3
6
PPAARRTTSSLLIISSTT
7
10
NOTE: Drawings for illustration purpose only. Actual product may vary. Not to scale.
8
11
9
* Optional
12
SAVE THESE INSTRUCTIONS
Page 4
(131) MODEL CS8110 SALTWATER SYSTEM ENGLISH 7.5” X 10.3” PANTONE 295U 07/28/2010
English
PARTS REFERENCE
Before assembling your product, please take a few minutes to check the contents
nd become familiar with all the parts.
a
5
1
2
4
3
7
2
6
2
8
131
9
10
NOTE: Drawings for illustration purpose only. Actual product may vary. Not to scale.
Operation is subject to the following two conditions: (1) this device may not cause
interference, and (2) this device must accept any interference, including
interference that may cause undesired operation of the device.
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
This equipment has been tested and found to comply with the limits for Class B
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and the receiver.
• Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
PPAARRTTSSRREEFFEERREENNCCEE
SAVE THESE INSTRUCTIONS
Page 5
(131) MODEL CS8110 SALTWATER SYSTEM ENGLISH 7.5” X 10.3” PANTONE 295U 07/28/2010
English
PARTS REFERENCE (continued)
Before assembling your product, please take a few minutes to check the contents
and become familiar with all the parts.
REF. NO.
PARTS FOR
COMMON
PARTS
CONNECTION
TO FILTER
PUMPS WITH
1-1/4" (32MM)
OSE SIZE
H
1
2O-RING A310712
3SCREW410713
4
5COPPER ELECTRODE111234
ADAPTOR A WITH THREADED COLLAR (OPTIONAL)
ELECTROLYTIC CELL (WITH TITANIUM
PLATES) (O-RING A INCLUDED)
DESCRIPTIONQTY.
110849
111233
SPARE
PART
O.
N
131
6FLOW SENSOR CONDUIT 111250
7FLOW SENSOR111143
8
9THREADED ADAPTOR B (OPTIONAL)110722
10
11CHLORINE TEST STRIPS119635
12COPPER TEST STRIPS111254
CONNECTOR HOSE WITH THREADED FITTINGS
CELL COVER
110720
211131
When ordering parts, be sure to quote the model number and part numbers.
PPAARRTTSSRREEFFEERREENNCCEE
SAVE THESE INSTRUCTIONS
Page 6
(131) MODEL CS8110 SALTWATER SYSTEM ENGLISH 7.5” X 10.3” PANTONE 295U 07/28/2010
English
HOW THE CHLORINE IS GENERATED
This product is specially designed for above ground pools. It will destroy the
bacteria, oxidize bather organics and control algae, which provide a safe, clean and
comfortable swimming pool.
ommon salt (sodium chloride) is made up of two elements, sodium and chloride.
C
During the installation of your Saltwater System, a measured quantity of salt is
dissolved in the pool water to make it slightly salty. The pool water flows through
the Saltwater System ’s electrolytic cell to produce chlorine. The chlorine dissolves
in the water and instantly starts destroying bacteria and algae. It also oxidizes all
other organic materials.
HOW COPPER IONS ARE GENERATED
Low voltage direct current is applied to the copper electrode, and copper ions are
generated and dissolved instantly in the water. Copper is an effective algaecide,
which will prevent algae from growing in the pool.
131
PRODUCT SPECIFICATIONS
Power:110 - 120 Volt AC
Amperage:1.1A
Wattage:125W
Ideal Salt Level:3000 ppm (parts per million)
Maximum Chlorine Output/hour:12 grams/hour
Copper Ionizer Output Current:175 mA
Minimum Flow Rate:
Limited Warranty:2 Years (see “Limited Warranty”)
(131) MODEL CS8110 SALTWATER SYSTEM ENGLISH 7.5” X 10.3” PANTONE 295U 07/28/2010
BOOST
English
SETUP INSTRUCTIONS
IMPORTANT
The Saltwater System requires a separate filter pump [700~4000 gph
•
(2650~15140 lph)] to drive the water and function properly.
• The Saltwater System must be installed as the last piece of pool
equipment in the water return line to the pool as displayed in Drawing
#1. This location extends the life of the titanium plates.
1. Assemble the above-ground-pool (AGP) and its filter pump according to their
installation instructions.
2. Take the Saltwater System and its accessories out of the packaging.
3. Place the Saltwater System in line after the filter pump.
4. Connect the connector hose (8) to the Saltwater System inlet.
Connecting the system to pump and pool with 1-1/4” (32mm)
connections/hoses:
The saltwater system features 1-1/2” (38mm) connections. It is accordingly
supplied with adaptors A (1) and B (9) for connecting to the small 1-1/4”
(32mm) diameter connections/hoses. Install as follows:
Drawing #1
131
WATER TO
POOL
ID 1-1/4” (32mm)
HOSE
WATER FROM
POOL
SWIMMING POOL
FILTER
PUMP
SALTWATER
SYSTEM
9
1
8
ID 1-1/4”
(32mm) HOSE
SSEETTUUPPIINNSSTTRRUUCCTTIIOONNSS
SAVE THESE INSTRUCTIONS
9
Page 8
(131) MODEL CS8110 SALTWATER SYSTEM ENGLISH 7.5” X 10.3” PANTONE 295U 07/28/2010
English
SETUP INSTRUCTIONS (continued)
1. Go directly to step 2 if your pool is empty. If your above-ground-pool is filled
with water, unscrew the strainer grids from the strainer connectors and insert
the black hat-like plugs into the connectors, before installing the saltwater pool
system.
2. Connect the adaptor A (1) to the electrolytic cell (4) outlet as shown in Drawing
#1. Tighten securely.
4
1
3. Disconnect the water return hose from the filter pump connection and connect
it to the adaptor A (1) on the Saltwater System with a hose clamp. (see
Drawing #1)
4. Connect adaptor B (9) to the connector hose (8). Tighten securely. (see
Drawing #1)
9
8
131
5. Connect adaptor B (9) to filter pump outlet (lower connection). Tighten
securely.
9
8
6. Remove the black hat-like plugs that prevent water from flowing out of the pool.
Now, return the strainer grids to the strainer connectors.