Intex krystal clear 602 Owner's Manual

257A
(257IO) MODEL 602 FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 05/24/2016
English
OWNER’S MANUAL
IMPORTANT
SAFETY RULES
Please read, understand, and follow all
and using this product. Keep for future
reference.
Don’t forget to try these other fine Intex products: pools, pool accessories, inflatable pools and in-home toys, airbeds and boats available at fine retailers or visit our website. Due to a policy of continuous product improvement, Intex reserves the right to change specifications and appearance, which may result in updates to the instruction manual without notice.
Krystal Clear™ Model 602 Filter Pump
220 - 240 V~, 50 Hz, 30 W Hmax 1.0 m, Hmin 0.19 m, IPX5/IPX7
Max. Water Temperature 35 °C
©2016 Intex Marketing Ltd. - Intex Development Co. Ltd. - Intex Trading Ltd.
- Intex Recreation Corp. All rights reserved/Tous droits réservés/Todos los derechos reservados/Alle Rechte vorbehalten. Printed in China/Imprimé en Chine/Impreso en China/Gedruckt in China.
®™ Trademarks used in some countries of the world under license from/®™ Marques utilisées dans certains pays sous licence de/ Marcas registradas utilizadas en algunos países del mundo bajo licencia de/Warenzeichen verwendet in einigen Ländern der Welt in Lizenz von/
Intex Marketing Ltd. to/à/a/an Intex Trading Ltd., Intex Development Co. Ltd., G.P.O Box 28829, Hong Kong & Intex
Recreation Corp., P.O. Box 1440, Long Beach, CA 90801
• Distributed in the European Union by/Distribué dans l’Union Européenne
par/Distribuido en la unión Europea por/Vertrieb in der Europäischen Union durch/
Intex Trading B.V., Venneveld 9, 4705 RR Roosendaal – The Netherlands www.intexcorp.com
257-*A*-R0-1705
For illustrative purposes only.
(257IO) MODEL 602 FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 05/24/2016
257A
SAVE THESE INSTRUCTIONS
English
Page 2
Warnings
.....................................................................................
3
Parts Reference
..........................................................................
4
Setup Instructions
......................................................................
5-7
Maintenance
................................................................................
7-8
Pool Care and Chemicals
...........................................................
8
Long Term Storage
......................................................................
8
Troubleshooting Guide
................................................................
9
Common Pool Problems
..............................................................
10
General Aquatic Safety
.................................................................
10
Limited Warranty
...........................................................................
11
TABLE OF CONTENTS
(257IO) MODEL 602 FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 05/24/2016
257A
SAVE THESE INSTRUCTIONS
English
Page 3
IMPORTANT SAFETY RULES
Read, Understand and Follow All Instructions Carefully Before Installing and Using this Product.
READ AND FOLLOW ALL INSTRUCTIONS
WARNING
These product warnings, instructions and safety rules provided with the product represent some
common risks of water recreation devices and do not cover all instances of risk and danger. Please
use common sense and good judgement when enjoying any water activity.
Always supervise children and those with disabilities.
• Children must stay away from this product and electrical cord(s).
• Children shall not play with the appliance. Cleaning and user maintenance shall not be made by
children without supervision
• This appliance can be used by children aged from 8 years and above and persons with reduced
physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
• Assembly and disassembly by adults only.
• Risk of electric shock. Connect this product only to a grounding type receptacle protected by a ground-fault circuit interrupter (GFCI) or residual current device (RCD). Contact a qualified electrician if you cannot verify that the receptacle is protected by a GFCI/RCD. Use a qualified electrician to install the GFCI/RCD, which has a maximum rate of 30mA. Do not use a portable residual current device (PRCD).
• Always unplug this product from the electrical outlet before removing, cleaning, servicing or
making any adjustment to the product.
• The plug must be accessible after produc t is installed.
• Do not bury the electrical cord. Locate the cord where it will not be damaged by lawn mowers,
hedge trimmers and other equipment.
• The supply cord cannot be replaced. If the cord is damaged the appliance should be scrapped.
• To reduce the risk of electric shock, do not use extension cords, timers, plug adaptors or
converter plugs to connect unit to electric supply; provide a properly located outlet.
• Do not attempt to plug in or unplug this product while standing in water or when your hands are
wet.
• Keep the plug of this product more than 3.5m away from the pool.
• Position this product away from the pool, so as to prevent children from climbing on it and
accessing the pool.
• Do not operate this product when the pool is occupied.
• This product is for use with storable pools only. Do not use with permanently installed pools. A
storable pool is constructed so that it may be readily disassembled for storage and reassembled to its original configuration.
The appliance is intended only for household use.
• This product is intended to be used only for the purposes described in the manual!
FAILURE TO FOLLOW THESE WARNINGS MAY RESULT IN PROPERTY DAMAGE, ELECTRIC SHOCK, ENTANGLEMENT OR OTHER SERIOUS INJURY OR DEATH.
(257IO) MODEL 602 FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 05/24/2016
257A
SAVE THESE INSTRUCTIONS
English
Page 4
PARTS REFERENCE
Before assembling your product, please take a few minutes to check the contents
and become familiar with all the parts.
When ordering parts, be sure to quote the model number and part numbers.
NOTE:
Drawings for illustration purpose only. Actual product may vary. Not to scale.
REF. NO.
DESCRIPTION QTY. SPARE PART NO.
1 AIR RELEASE VALVE 1 10460 2 VALVE O-RING 1 10264
3
FILTER HOUSING COVER
1
11917
4 COVER SEAL 1
11919
5
FILTER CARTRIDGE (29007)
1
6 HOSE SEAL 2 10134 7 HOSE CLAMP 4 11489
8 HOSE 2
10399
9 STRAINER CONNECTOR
1
11070
10
POOL INLET JET NOZZLE
1
12364
11 STRAINER GRID 1
12197
12 THREADED FILTER HOUSING COLLAR 1
11918
13 INLET STRAINER CONNECTOR 1 12365
*14 AIR JET VALVE 1 12363 *15 POOL INLET AIR ADAPTOR 1 12366 *16 AIR JET VALVE CAP (NOT SHOWN) 1 12373
Type of lter medium Synthetic cartridge #29007
No tools are required for the assembly.
" * ":
Optional.
1 2
3 4
5
6
7 8
13
9
11
10
ABC
12
15
14
(257IO) MODEL 602 FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 05/24/2016
257A
SAVE THESE INSTRUCTIONS
English
Page 5
SETUP INSTRUCTIONS
Be sure you have access to water to fill the pool and chemicals for the water.
IMPORTANT: This filter pump is shipped with the air release valve (1) open (open the air release valve if necessary). DO NOT replace the air release valve until you reach STEP #8. Failure to follow these instructions will result in air trapped inside filter housing; the motor will run dry, be noisy and malfunction.
1.
Assemble above-ground-pool first. Carefully follow the pool’s installation instructions.
2.
Place the filter pump the length of the hose away from the pool wall where the lower black
protruding hose connection is "sticking-out". Ensure the filter pump is accessible at all time for
service and maintenance.
3.
Insert the nozzle union
(13 & 10)
into the upper protruding hose connections, and then attach
the pool inlet air adaptor
(15)
to the upper protruding fitting. Screw the air jet valve
(14)
over
the pool inlet air adaptor
(15)
. Then insert the strainer union
(9 & 11)
into the lower protruding
hose connections. The hoses
(8)
fit over the strainers inserted into the connections.
4.
There are two hoses to be connected to the filter pump hose connections. With hose clamps
(7)
,
fasten one of the hoses
(8)
to the lower protruding hose connection (marked "+" on the pool
liner) and to the upper pump connection (marked "+").
5.
Connect the second hose to the pool inlet air adaptor
(15)
and to the lower pump connection.
Make sure all the hose clamps
(7)
are tight.
NOTE:
Make sure the air jet valve
(14)
is securely
tighten onto the pool inlet air adaptor
(15)
and facing up.
6.
In a counter-clockwise motion unscrew the threaded filter housing collar
(12)
from the filter
housing. Grasp and remove the housing cover
(3)
. Check to see if a cartridge is inside the
housing. If yes, replace the cover, finger tighten the housing collar
(12)
back onto the filter
housing.
7.
Fill the pool to a level of at least 1-2 inches above the top connection. The water will
automatically flow down into the pump.
8.
When water starts flowing out of the air release valve hole, screw in the air release valve back
into the filter housing cover. Do not over tighten the valve.
NOTE: Venting the system is
necessary for air to escape as the filter housing fills with water.
9.
Connect the filter pump to the power outlet. The filter pump is now filtering the water.
10.
Operate the filter pump until the desired water clarity is obtained.
NOTE:
Never put pool chemicals directly into the filter pump. This may damage the pump
and void the warranty.
WARNING
Risk of electric shock. Connect this product only to a grounding type receptacle protected by a ground-fault circuit interrupter (GFCI) or residual current device (RCD). Contact a qualified electrician if you cannot verify that the receptacle is protected by a GFCI/RCD. Use a qualified electrician to install the GFCI/RCD, which has a maximum rate of 30mA. Do not use a portable residual current device (PRCD).
(257IO) MODEL 602 FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 05/24/2016
257A
SAVE THESE INSTRUCTIONS
English
Page 6
SETUP INSTRUCTIONS (continued)
It is essential to change any damaged element or set of elements as soon as possible. Use only parts approved by the manufacturer.
To inspect and change the filter cartridge, disconnect line cord, unscrew the pool inlet nozzle
(10)
and strainer grid
(11)
from the strainer connectors and insert the hat-like plugs into the strainer connectors before servicing the filter. After service, open the air release valve, remove the plugs, allow any air to escape through the valve before tightening the valve again and replace the pool inlet nozzle
(10)
and strain grid
(11)
. The pump is now primed with water
again and may be turned on.
(ILLUSTRATION NOT TO SCALE)
WATER LEVEL
INSIDE OF POOL
STRAINER GRID
(REMOVE)
POOL INLET
JET NOZZLE
(REMOVE)
PLUG
UPPER PUMP CONNECTION
LOWER PUMP
CONNECTION
FILTER
CARTRIDGE
INSIDE
AIR RELEASE
VALVE
HOSE
W
A
T
E
R
D
I
R
E
C
T
I
O
N
W
A
T
E
R
D
I
R
E
C
T
I
O
N
FILTER HOUSING
COVER
THREADED FILTER
HOUSING COLLAR
POOL INLET
AIR ADAPTOR
AIR JET
VALVE
HOSE
CLAMP
WARNING
Position this product away from the pool, so as to prevent children from climbing on it and accessing the pool.
The power cord plug to the 220-240 volt electrical power source of the filter pump must be
positioned more than 3.5 m away from the pool walls. Check your local authorities to determine
the appropriate standard and requirements for “electrical installation of swimming pools and basins equipment”. The following table is for reference only:
International
France
Germany
The Netherlands
Country/Region
Standard Number
IEC 60364-7-702 NF C 15-100-7-702 DIN VDE 0100-702
NEN 1010-702
(257IO) MODEL 602 FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 05/24/2016
257A
SAVE THESE INSTRUCTIONS
English
Page 7
FILTER PUMP STATIONARY MOUNTING OPTION
There are three mounting holes located at the bottom of the filter pump base. These
holes are provided because various country’s regulations, especially in the European
community, require the filter pump to be secured to the ground or to a base in a permanent upright position. These three holes form a triangle pattern and the holes are slotted with a 7mm width. The filter pump can be mounted on a cement base or onto a wooden structure to prevent
accidental falling over. Total assembly must exceed 18kg. The drawings on the following
show two possible ways of upright mounting.
-- (3) x M6 HEXAGON HEAD BOLTS
119mm
119mm
91mm
119mm
91mm
119mm
-- (3) x M6 HEXAGON LOCK-NUTS
It is recommended that the filter cartridge be replaced at least every 2 weeks. Regularly monitor the filter clogging level.
1.
Make sure filter pump is not operating. Disconnect line cord.
2.
To prevent water from escaping the pool, unscrew the pool inlet nozzle
(10)
and strainer grid
(11)
from the strainer connectors and insert the hat-like plugs into the strainer connectors.
3.
In a counter-clockwise motion, remove the filter housing collar
(12)
and threaded cover
(3)
. Be
careful not to lose the cover seal
(4)
.
4.
Remove filter cartridge
(5)
to clean it. The filter may be cleaned from the spray from a water
hose.
5.
Use judgement as to whether cartridge needs to be replaced. Only use the original Intex
cartridge for replacement. See “Parts Reference” section for detail.
6.
Return cartridge to filtering position.
7.
Return the seal
(4)
and threaded cover
(3)
to their original positions and in a clockwise direction
rescrew the housing collar
(12)
onto the filter housing.
8.
After service, open the air release valve, remove the plugs, allow any air to escape through the
valve before tightening the valve again and replace the pool inlet nozzle
(10)
and strainer grid
(11).
The pump is now primed with water again and may be turned on.
9.
Check the inlet and outlet openings regularly to ensure they are not obstructed thus preventing
a good filtration.
10.
The disposal of any used filter media should be in accordance with applicable local regulation
and legislation.
CLEANING OR REPLACING FILTER CARTRIDGES
(257IO) MODEL 602 FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 05/24/2016
257A
SAVE THESE INSTRUCTIONS
English
POOL CARE AND CHEMICALS
All pools require care to keep the water clear and hygienically clean. With proper chemical control, your filter will help attain this objective. Consult your pool supply dealer for
instructions regarding the proper use of chlorine, algaecide and other chemical agents required for sparkling clear water.
Keep pool chemicals away from children.
Do not replenish chemicals in pool while pool is occupied. Skin or eye irritations could occur.
Daily pH checking and chemical treatment of the water is very important and can not be overemphasized. Chlorine, algaecide and maintenance of proper pH levels are required when filling the pool as well as during the season. Consult your local swimming pool supply
store for instructions.
The season's first filling of the pool may have brackish water requiring extra water additives and extra filter changes. Do not allow swimming in pool until the pH level is balanced. Consult your local swimming pool supply store for instructions.
Keep spare filter cartridges on hand. Replace cartridges every two weeks.
Chlorinated water may damage lawns, gardens or shrubbery as children play in the pool and splash water outside the pool. Lawn areas underneath the pool liner will be destroyed. Note
that some types of grass may grow through the liner.
Filter run time depends on pool size, weather and usage level. Experiment with various run
times so as to produce clean clear water.
European standard EN16713-3 lists some additional pool water quality and water treatment
information that can be found at www.intexcorp.com/support.
CAUTION
Concentrated chlorine solutions may damage the pool liner. Always follow the chemical manufacturer’s directions, and the health and hazard warnings.
Page 8
1.
Before emptying your pool for long term storage, or relocation, be sure the water is directed
towards an acceptable drain water receptacle away from the house. Check local regulations
for specific directions regarding disposal of swimming pool water.
2
. Now, drain the pool.
3.
When the pool is empty, disconnect all pool hoses
(8)
from the pool and filter pump, simply
reverse the set up instructions.
4.
Remove the filter cartridge as shown in the Filter Cartridge Cleaning section, steps 2 thru 4.
5.
Remove the nozzle and strainer unions from the pool wall. Place the wall plugs into the hose
connections. Loosen clamps
(7)
securing the strainer connectors
(9)
before removal.
6.
Drain water from the filter pump housing.
7.
Leave filter pump pieces and hoses outside to thoroughly air dry.
8.
Depending on the cartridge
(5)
usage, a new cartridge may be needed for next season, keep
a spare available.
9.
Cover the seal
(4)
, air release valve O-ring
(2)
and hose seals
(6)
with petroleum jelly to
preserve its resilience during storage.
10.
Store the unit and accessories in a dry place. The storage's temperature should be controlled, between 32 degrees Fahrenheit (0 degrees Celsius) and 104 degrees Fahrenheit (40 degrees Celsius) storage location.
11.
The original packing can be used for storage.
LONG TERM STORAGE
(257IO) MODEL 602 FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 05/24/2016
257A
SAVE THESE INSTRUCTIONS
English
Page 9
TROUBLESHOOTING GUIDE
FILTER MOTOR FAILS TO START
FILTER DOESN’T CLEAN POOL
FILTER DOESN’T PUMP WATER OR FLOW IS VERY SLOW
PUMP DOESN’T WORK
TOP COVER LEAKING
HOSE LEAKING
AIR LOCK
POOL INLET AIR ADAPTOR / AIR JET VALVE LEAKING
• The motor is not plugged in.
• The GFCI/RCD circuit breaker
is tripped.
• Motor too hot and overload
protection is shut off.
• Improper chlorine or pH levels.
• Filter cartridge is dirty.
• Damaged cartridge.
• Excessively dirty pool.
• The strainer screen is
restricting the water flow.
• Clogged inlet or discharge.
• An air leak on the intake line.
• Scale or buildup on cartridge.
• Excessively dirty pool.
• Dirty filter cartridge.
• The nozzle and strainer
connection are reversed.
• Pool inlet air adaptor connected to
the wrong fitting.
• Low water level.
• Strainer screen plugged up.
• An air leak on the intake hose.
• Faulty motor or the impeller is
jammed.
• An air lock inside the cartridge
chamber.
• O-ring missing.
• Cover or air release valve are not
tight.
• Hose clamps are not well-fitted.
• Hose o-ring dislodged when
connecting the hose.
• Hose broken.
• There’s air trapped in the pump
housing and inlet hose.
• Hose clamps are not well-fitted.
• Air jet valve is not tight and
facing up.
• Air jet valve internal seal blocked.
• Air jet valve internal seal dirty.
• Air jet valve broken.
TROUBLE CAUSE SOLUTION
• Filter cord must be plugged into a 3 wire outlet that is protected by a Class A Ground Fault Circuit Interrupter, or RCD.
• Reset circuit breaker. If circuit breaker
trips repeatedly, your electrical system may have a defect. Turn off circuit breaker and call an electrician to correct the problem.
• Let the motor cool down.
Adjust the chlorine and pH level. Consult
your local swimming pool supply stores.
Clean or replace cartridge.
Check the cartridge for holes. Replace if
damaged.
Operate the filter for longer periods.
Clean the strainer screen at the inlet.
• Clear any obstructions in the intake hose by
discharging it inside pool wall.
• Tighten hose clamps, check hoses for
damage, check pool water level.
• Replace cartridge.
• Clean cartridge more often.
• Install the nozzle at the upper position of the
pool inlet, and the strainer at the lower position of the pool outlet.
• Make sure the pool inlet air adaptor is
connected to the pool inlet upper fitting.
• Fill pool to correct water level.
• Clean strainer screens at pool inlet.
• Tighten hose clamps, check hose for
damage.
• Clear any sticks or leaves in the intake hose.
• Open the release valve at top of pump.
• Remove cover & check for O-ring.
• Tighten cover or valve (Manually).
• Tighten or change hose clamps.
• Put the o-ring back into the groove.
• Replace a new hose.
• Open air release valve, lift and lower the
inlet hose until water starts to flow out of the air release valve, close air release valve.
• Tighten or reinstall hose clamps.
• Tighten air jet valve and make sure it’s
facing up.
• Plug in the pump and run for few seconds, then unplug, repeat 3 times.
• Remove air jet valve, flush dirt out with water
and replace valve back.
• Replace a new air jet valve.
(257IO) MODEL 602 FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 05/24/2016
257A
SAVE THESE INSTRUCTIONS
English
IMPORTANT
If you continue to experience difficulty, please contact our Consumer Service Department for assistance. See separate "Authorized Service Centers" sheet.
Page 10
COMMON POOL PROBLEMS
PROBLEM DESCRIPTION CAUSE SOLUTION
ALGAE
COLORED WATER
SUSPENDED MATTER IN WATER
CHRONIC LOW WATER LEVEL
SEDIMENT ON POOL BOTTOM
SURFACE DEBRIS
• Chlorine and pH levels
need adjustment.
• Copper, iron or manganese
in water being oxidized by the added chlorine.
This is Common.
• "Hard water" caused by a too high pH level.
• Chlorine content is low.
• Foreign matter in water.
• Rip or hole in pool
liner or hoses.
• The drain valves are loose.
• Heavy use, getting in
and out of pool.
• Pool too close to trees.
• Super chlorinate with shock treatment. Correct pH to your pool store's recommended level.
• Vacuum pool bottom.
• Maintain proper chlorine level.
• Adjust pH level to the
recommended level.
• Run filter until water is clear.
• Clean cartridge frequently.
• Correct the pH level. Check
with your pool dealer for advice.
• Adjust the chlorine level.
• Clean or replace your filter.
• Repair with a patch kit.
• Finger tighten all caps.
• Use Intex pool vacuum to
clean bottom of pool.
• Use Intex pool skimmer.
• Greenish water.
• Green or black
spots on pool liner.
• Pool liner is slippery
and/or has a bad odor.
• Water turns blue,
brown, or black when first treated with chlorine.
• Water is cloudy or
milky.
• Level is lower than
on previous day.
• Dirt or sand on
pool floor.
• Leaves, insects etc.
GENERAL AQUATIC SAFETY
Water recreation is both fun and therapeutic. However, it involves inherent risks of injury and death. To reduce your risk of injury, read and follow all product, package and package insert warnings and instructions. Remember, however, that product warnings, instructions and safety guidelines cover some common risks of water recreation, but do not cover all risks and or dangers.
For additional safeguards, also familiarize yourself with the following general guidelines as well as guidelines provided by nationally recognized Safety Organizations:
• Demand constant supervision. A competent adult should be appointed as a “lifeguard” or
water watcher, especially when children are in and aroundthe pool.
• Learn to swim.
• Take the time to learn CPR and first aid.
• Instruct anyone who is supervising pool users about potential pool hazards and about the
use of protective devices such as locked doors, barriers, etc.
• Instruct all pool users, including children what to do in case of an emergency.
• Always use common sense and good judgement when enjoying any water activity.
• Supervise, supervise, supervise.
(257IO) MODEL 602 FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 05/24/2016
257A
SAVE THESE INSTRUCTIONS
English
Page 11
Your Krystal Clear™ Filter-Pump has been manufactured using the highest quality materials and workmanship. All Intex products have been inspected and found free of defects prior to
leaving the factory. This limited warranty applies only to the Krystal Clear™ Filter-Pump and accessories listed below.
This limited warranty is in addition to, and not a substitute for, your legal rights and remedies. To the extent that this warranty is inconsistent with any of your legal rights, they take priority.
For example, consumer laws across the European Union provide statutory warranty rights in addition to the coverage you receive from this limited warranty: for information on EU-wide consumer laws, please visit the European Consumer Center website at http://ec.europa.eu/
consumers/ecc/contact_en/htm.
The provisions of this limited warranty apply only to the original purchaser and are not transferable. This limited warranty is valid for the period noted below from the date of the
initial retail purchase. Keep your original sales receipt with this document, as proof of
purchase will be required and must accompany warranty claims or the Limited Warranty is invalid. Krystal Clear™ Filter-Pump Warranty – 1 Year
Hoses & Fittings Warranty – 180 days
If you find a manufacturing defect in the Krystal Clear™ Filter-Pump during the warranty periods noted above, please contact the appropriate Intex Service Center listed in the separate “Authorized Service Centers” sheet. If the item is returned as directed by the Intex Service Center, the Service Center will inspect the item and determine the validity of the claim. If the item is covered by the provisions of the warranty, the item will be repaired or replaced, with the same or comparable item (at Intex’s choice) at no charge to you.
Other than this warranty, and other legal rights in your country, no further warranties are implied. To the extent possibly in your country, in no event shall Intex be liable to you or any third party for direct or consequential damages arising out of the use of your Krystal Clear™ Filter-Pump, or Intex or its agents’ and employees’ actions (including the manufacture of the product). If your country does not allow the exclusion or limitation of incidental or
consequential damages, this limitation or exclusion does not apply to you.
You should note that this limited warranty does not apply in the following circumstances:
• If the Krystal Clear™ Filter-Pump is subject to negligence, abnormal use or application,
accident, improper operation, improper voltage or current contrary to operating instructions, improper maintenance or storage;
• If the Krystal Clear™ Filter-Pump is subject to damage by circumstances beyond Intex’s
control, including but not limited to, ordinary wear and tear and damage caused by exposure to fire, flood, freezing, rain, or other external environmental forces;
• To parts and components not sold by Intex; and/or
• To unauthorized alterations, repairs or disassembly to the Krystal Clear™ Filter-Pump by anyone other than Intex Service Center personnel.
The costs associated with the loss of pool water, chemicals or water damage are not
covered by this warranty. Injury or damage to any property or person is not covered by this
warranty.
Read the owner’s manual carefully and follow all instructions regarding proper operation and maintenance of your Krystal Clear™ Filter-Pump. Always inspect your product prior to use.
This limited warranty will be void if use instructions are not followed.
LIMITED WARRANTY
257B
(257IO) MODEL 602 FILTER PUMP DANISH 7.5” X 10.3” PANTONE 295U 05/24/2016
Dansk
BETJENINGSVEJLEDNING
VIGTIGT
SIKKERHEDSREGLER
Sørg for at læse, forstå og følge alle
instruktionerne nøje, før du installerer
produktet og tager det i brug.
Opbevares til senere brug.
Prøv også disse andre fine Intex produkter: pools, pool tilbehør, oppustelige pools og indendørs legetøj, luftmadrasser og både kan findes hos store forhandlere eller besøg vores hjemmeside. Som led i vores politik om hele tiden at forbedre vores produkter, forbeholder Intex sig retten til uden varsel at ændre specifikationer og design, hvilket kan resultere i opdateringer af denne vejledning.
Krystal Clear™ Model 602 Filterpumpe
220 - 240 V~, 50 Hz, 30 W Hmax 1.0 m, Hmin 0.19 m, IPX5/IPX7
Maks. Vandtemperatur: 35 °C
©2016 Intex Marketing Ltd. - Intex Development Co. Ltd. - Intex Trading Ltd.
- Intex Recreation Corp. All rights reserved/Tous droits réservés/Todos los derechos reservados/Alle Rechte vorbehalten. Printed in China/Imprimé en Chine/Impreso en China/Gedruckt in China.
®™ Trademarks used in some countries of the world under license from/®™ Marques utilisées dans certains pays sous licence de/ Marcas registradas utilizadas en algunos países del mundo bajo licencia de/Warenzeichen verwendet in einigen Ländern der Welt in Lizenz von/
Intex Marketing Ltd. to/à/a/an Intex Trading Ltd., Intex Development Co. Ltd., G.P.O Box 28829, Hong Kong & Intex
Recreation Corp., P.O. Box 1440, Long Beach, CA 90801
• Distributed in the European Union by/Distribué dans l’Union Européenne
par/Distribuido en la unión Europea por/Vertrieb in der Europäischen Union durch/
Intex Trading B.V., Venneveld 9, 4705 RR Roosendaal – The Netherlands www.intexcorp.com
Kun til illustration.
(257IO) MODEL 602 FILTER PUMP DANISH 7.5” X 10.3” PANTONE 295U 05/24/2016
257B
GEM DENNE VEJLEDNING
Dansk
Side 2
Advarsel
...........................................................................
3
Indholdsliste
.....................................................................
4
Opstillingsvejledning
.....................................................
5-7
Vedligeholdelse
...............................................................
7-8
Pleje af poolen og kemikalier
.........................................
8
Vinteropbevaring
.............................................................
8
Fejlfindingsvejledning
....................................................
9
Almindelige poolproblemer
............................................
10
Generelle sikkerhedsregler
............................................
10
Begrænset garanti
...........................................................
11
INDHOLDSFORTEGNELSE
(257IO) MODEL 602 FILTER PUMP DANISH 7.5” X 10.3” PANTONE 295U 05/24/2016
257B
GEM DENNE VEJLEDNING
Dansk
Side 3
VIGTIGT SIKKERHEDSREGLER
Sørg for at læse, forstå og følge alle instruktionerne nøje, før du installerer produktet og tager det i brug.
LÆS OG FØLG ALLE ANVISNINGERNE
ADVARSEL
Disse produktadvarsler, anvisninger og sikkerhedsregler, der følger med produktet, dækker nogle
almindeligt forekommende risici ved vandsportsudstyr og omfatter ikke alle fare- og risicimomenter. Brug din sunde fornuft og almindelige dømmekraft i forbindelse med vandaktiviteter.
Hold altid opsyn med børn og handicappede personer.
• Hold produktet og ledningen/ledningerne utilgængelige for børn.
• Børn må ikke lege med apparatet. Børn må ikke rengøre eller vedligeholde apparatet uden opsyn
af en voksen.
• Dette apparat må kun anvendes af børn fra 8 år og opefter og af personer med nedsatte fysiske
og metale evner, nedsat følelse eller mangel på erfaring og viden, hvis de er under opsyn eller har fået vejledning i sikker brug af apparatet og forstår risikoen ved at bruge det.
• Samling og demontering må kun foretages af voksne.
• Fare for elektrisk stød. Dette produkt må kun sluttes til et jordstik, der er beskyttet med en jordfejlsafbryder (HFI) eller fejlstrømsafbryder. Kontakt en elektriker, hvis du ikke er sikker på, at stikket er beskyttet med HFI. Få en elektriker til at installere HFI, som udløses ved maks. 30 mA. Undlad at bruge en transportabel fejlstrømsafbryder.
• Tag altid stikket ud af stikkontakten, før du flytter produktet, gør det rent, udfører service på det
eller foretager justeringer af det.
• Der skal være adgang til stikket, efter at produktet er blevet installeret.
• Undgå at nedgrave ledningen. Placer ledningen et sted, hvor den ikke bliver beskadiget af
plæneklippere, hækkesakse og andet udstyr.
• Denne strømledning kan ikke udskiftes. Hvis ledningen beskadiges bør enheden skrottes.
• For at reducere risikoen for elektrisk stød skal du undgå at anvende forlængerledninger,
timere, stikadaptere eller stikomformere for at slutte enheden til strømforsyningen. Brug en fastmonteret stikkontakt.
• Undgå at slutte stikket til eller at trække det ud, hvis du står i vand eller har våde hænder.
• Stikket til produktet skal som minimum placeres 3,5 m fra poolen.
• Anbring produktet væk fra poolen for at forhindre, at børn kravler op på pumpen for at komme i
poolen.
• Undgå at bruge dette produkt, mens poolen er i brug.
• Dette produkt er kun beregnet til brug med pools, der kan gemmes væk efter brug. Det må ikke bruges til pools, der er fast installeret. En flytbar pool, der kan gemmes væk for vinteren, er
konstrueret, så den er nem at skille ad og samle igen.
Kun beregnet til privat brug.
• Dette produkt er kun beregnet til brug til de formål, der er beskrevet i brugsanvisningen!
MANGLENDE OVERHOLDELSE AF DISSE ADVARSLER KAN MEDFØRE TINGSSKADE, ELEKTRISK STØD, SAMMENFILTRING, ANDEN ALVORLIG PERSONSKADE ELLER DØDSFALD.
(257IO) MODEL 602 FILTER PUMP DANISH 7.5” X 10.3” PANTONE 295U 05/24/2016
257B
GEM DENNE VEJLEDNING
Dansk
Side 4
INDHOLDSLISTE
Før du installerer produktet, skal du bruge et par minutter på at kontrollere indholdet
og gør dig fortrolig med delene.
" * ":
V
algfrit
.
Oplys modelnummer og reservedelsnummer i forbindelse med bestilling af reservedele.
Der skal ikke bruges værktøjer til montering.
BEMÆRK:
Tegningerne er kun til illustration. Viser ikke det korrekte produkt. Er ikke i skala.
N° DE PIÈCE
BESKRIVELSE
ANTAL
RESERVEDEL NUMMER
1 LUFTVENTIL 1 10460 2
O-RING TIL VENTI
L
1 10264
3
DÆKSEL TIL FILTERHUS
1
11917
4 COVER FORSEJLING 1
11919
5
FILTERINDSATS (29007)
1
6 SLANGEPAKNING 2 10134 7 SLANGEKLEMME 4 11489
8 SLANGE 2
10399
9 FILTERTILSLUTNING
1
11070
10
STRÅLEDYSE TIL INDLØB
1
12364
11 SINET 1
12197
12 GEVINDSKÅRET RING TIL FILTERHUS 1
11918
13
FORBINDELSESSTYKKE MED FILTER TIL INDLØB
1 12365
*14
DYSEVENTIL
1 12363
*15
ADAPTER TIL POOLINDLØB
1 12366
*16
HÆTTE TIL DYSEVENTIL ( IKKE VIST)
1 12373
Type af ltermedie: Syntetisk indsats #29007
1
2
3 4
5
6
7 8
13
9
11
10
ABC
12
15
14
(257IO) MODEL 602 FILTER PUMP DANISH 7.5” X 10.3” PANTONE 295U 05/24/2016
257B
GEM DENNE VEJLEDNING
Dansk
Side 5
OPSTILLINGSVEJLEDNING
Sørg for at du har adgang til vand til at opfylde poolen og kemikalier til vandet.
VIGTIGT: Denne filterpumpe er forsendt med en luftventil (1) åben (åben luftventilen hvis
nødvendigt). Udskift IKKE luftventilen før du er nået SKRIDT #8. Følges disse
instruktioner ikke fører det til at luft fanges indeni filteret; motoren løber tør; laver støj og funktionsfejl.
1.
Saml først den ovenstående pool. Følg poolens installationsinstruktioner grundigt.
2.
Placer filterpumpen, i afstand af slangens længde, væk fra poolen hvor den nedre sorte
fremstående slangeforbinder “stikker ud”. Sørg for, at filterpumpen til alle tider er tilgængelig for service og vedligeholdelse.
3.
Sæt dysesamlingen
(13 & 10)
i de øvre slange-forbindelser, der stikker ud, og sæt
derefter luftadapteren til poolindløbet
(15)
på det øvre forbindelsesstykke, der stikker ud.
Skru dyseventilen
(14)
på adapteren til pool-indløbet
(15)
. Sæt herefter filtersamlingen
(9 & 11)
i den nederste udstående slangesamling. Slangerne
(8)
passer over filtrene
indsat i forbinderne.
4.
Der er to slanger som skal forbindes til filterpumpe slangeforbindelserne. Med
slangeklemmer
(7)
påsættes en af slangerne
(8)
til den nederste udstående slangesamling
(mærket ”+” på pooldugen) og til den øverste pumpetilslutning (mærket ”+”).
5.
Sæt den anden slange på adapteren til pool-indløbet
(15)
og til den nedre
pumpeforbindelse. Sørg for at alle slangeklemmer
(7)
er strammet ordentligt.
BEMÆRK:
Sørg for, at dyseventilen
(14)
spændes ordentligt fast på adapteren til pool-indløbet
(15)
og at den vender opad.
6.
Skru den gevindskårne ring til filterhuset
(12)
af filterhuset ved at dreje den mod uret.
Afmonter filterhusets dæksel
(3)
. Kontrollér, om der sidder en indsats i huset. Hvis det er
tilfældet, skal du montere dækslet igen og stramme ringen
(12)
på filterhuset med fingrene.
7.
Fyld poolen til at niveau mindst 2,5-5 cm over den øverste forbinder. Vandet vil automatisk
føres ned i pumpen.
8.
Når vandet begynder at flyde ud af luftventilhullet, skru luftventilen tilbage i filtercoveret.
Stram ikke ventilen for meget.
BEMÆRK: Udluftningssystemet er nødvendigt for at
lukke luft ud, idet filteret fyldes med vand.
9.
Forbind filterpumpen til strømforsyningen. Filterpumpen filtrerer nu vandet.
10.
Anvend filterpumpen indtil den ønskede klarhed i vandet er opnået.
BEMÆRK:
Kom aldrig kemikalier direkte ind i filterpumpen. Dette kan beskadige pumpen
og ugyldiggøre garantien.
ADVARSEL
Fare for elektrisk stød. Dette produkt må kun sluttes til et jordstik, der
er beskyttet med en jordfejlsafbryder (HFI) eller fejlstrømsafbryder. Kontakt en elektriker, hvis du ikke er sikker på, at stikket er beskyttet
med HFI. Få en elektriker til at installere HFI, som udløses ved maks.
30 mA. Undlad at bruge en transportabel fejlstrømsafbryder.
(257IO) MODEL 602 FILTER PUMP DANISH 7.5” X 10.3” PANTONE 295U 05/24/2016
257B
GEM DENNE VEJLEDNING
Dansk
Side 6
OPSTILLINGSVEJLEDNING (fortsat)
ADVARSEL
Anbring produktet væk fra poolen for at forhindre, at børn kravler op på pumpen for at komme i poolen.
Det er vigtigt at udskifte beskadigede elementer eller elementsæt snarest muligt. Brug kun dele, som anbefales af producenten.
For at checke og udskifte filterindsatsen, tages ledningen ud af stikkontakten og mundstykket
(10)
og filteret
(11)
skrues af filtertilslutningerne, hvorefter de hattelignende propper sættes i.
Efter service åbnes luftventilen og propperne tages ud og erstattes af mundstykket
(10)
og
filteret
(11)
. Lad evt. Luft komme ud gennem luftventilen inden den lukkes til igen. Pumpen er
nu fyldt med vand og kan tilsluttes igen.
Den elektriske strømkilde (220-240 volt), som filterpumpens strømkabel skal tilsluttes, skal være over 3,5 m fra poolvæggen. Kontakt de lokale myndigheder for gældende standarder og krav angående installation af pools og tilhørende udstyr. Følgende tabel er kun vejledende:
Internationalt
Frankrig
Tyskland
Holland
Land
Standardnummer
IEC 60364-7-702 NF C 15-100-7-702 DIN VDE 0100-702
NEN 1010-702
VANDSTAND
INDERSIDE
AF POOL
SINET
(FJERN)
STRÅLEDYSE TIL
INDLØB
(FJERN)
STIK
ØVRE
PUMPEFORBINDER
NEDERSTE
PUMPEFORBINDER
FILTERENHED
INDENI
LUFTVENTIL
SLANGE
DÆKSEL TIL
FILTERHUS
GEVINDSKÅRET
RING TIL FILTERHUS
ADAPTER TIL POOLINDLØB
DYSEVENTIL
SLANGEPAKNING
( ILLUSTRATIONEN ER IKKE I KORREKT MÅLESTOKSFORHOLD)
V
A
N
D
E
T
S
R
E
T
N
I
N
G
V
A
N
D
E
T
S
R
E
T
N
I
N
G
Loading...
+ 38 hidden pages