Intesis INMBSRTR0320000 User guide

© HMS Industrial Networks S.L.U - All rights reserved
This information is subject to change without notice
1 / 2
INMBSRTR0320000
Modbus RTU to Modbus TCP Router
Order Codes:
INMBSRTR0320000 (32 full-load devices)
The Intesis INMBSRTR0320000 Router has been specially designed to route messages between Modbus RTU and Modbus TCP networks.
Intesis acts as a transparent gateway between Modbus RTU and Modbus TCP networks, making its configuration simple and fast. It makes accessible Modbus RTU devices, its registers and resources to a Modbus TCP client BMS or controller. When the gateway receives a Modbus TCP packet from the TCP network, it simply routes the packet to the serial port.
Modbus TCP devices are connected through the Ethernet port, while Modbus RTU devices are connected to the serial port of the gateway.
Configuration project is done through Intesis MAPS.
Support for up to 5 simultaneous Modbus TCP Clients
Support for up to 32 full-load RTU devices
Modbus diagnose signals available in both MAPS and as Modbus
registers
Configuration through IP
Onboard LED indicators to provide easy to check communication
status on both the Ethernet and serial ports
Includes Intesis MAPS with automatic updates for both Intesis MAPS and Gateway’s firmware
UL certification
HOW IT WORKS
FEATURES
INTEGRATION EXAMPLE
© HMS Industrial Networks S.L.U - All rights reserved
This information is subject to change without notice
2 / 2
Modbus
RTU
TCP
Connection
EIA485
(3 wire isolated)
10BASE-T
100BASE-TX
Date rate
2.4, 4.8, 9.6, 19.2,
38.4, 57.6, 115.2kbps
10 Mbps
100 Mbps
Data Types & Functions
supported
All supported by clients
Enclosure
Plastic, type PC (UL 94 V-0) Net dimensions (dxwxh): 93x53x58 mm Recommended space for installation (dxwxh): 100x60x70mm Color: Light Grey. RAL 7035
Mounting
Wall. DIN rail EN60715 TH35.
Terminal Wiring
(for power supply and low-voltage signals)
Per terminal: solid wires or stranded wires (twisted or with ferrule)
1 core: 0.5mm
2
… 2.5mm
2
2 cores: 0.5mm
2
… 1.5mm
2
3 cores: not permitted
Power
1 x Plug-in screw terminal block (3 poles)
Positive, Negative, Earth 9-24VDC +/-10% Max.: 205mA
Ethernet
1 x Ethernet 10/100 Mbps RJ45 2 x Ethernet LED: port link and activity
Port
1 x Serial EIA485 (Plug-in screw terminal block 3 poles) A, B, SGND (Reference ground or shield)
1500VDC isolation from other ports
Operation Temperature
0°C to +60°C
Operational Humidity
5 to 95%, no condensation
Protection
IP20 (IEC60529)
CONNECTIONS
ELECTRICAL & MECHANICAL FEATURES
PROTOCOLS
COMMUNICATION
Modbus Protocol is a de facto standard, truly open and the most widely used network protocol in the industrial manufacturing environment. Modbus is used in multiple applications to monitor and program devices; to communicate between intelligent devices, sensors and instruments; to monitor field devices using PCs and HMIs.
But Modbus is not only an industrial protocol. Building, infrastructure, transportation and energy applications also make use of its benefits.
For further information visit www.modbus.org 70mm (h)
60 mm (w)
100 mm (d)