Intertek Jøtul GI 535 DV IPI, 157784, 157785 Fuel Conversion Instructions

Direct Vent Fireplace Insert
Jøtul GI 535 DV IPI
Fuel Conversion
New Harbor
Instructions
Kit 157784 - NG to LP
NOTE: IN ORDER TO EASILY ACCESS THE STEPPER MOTOR COMPONENTS, COMPLETE THE FUEL CONVERSION PROCEDURE BEFORE PLACING THE INSERT WITHIN THE FIREPLACE.
This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion, or production of carbon monoxide may result causing property damage, personal injury or loss of life. The qualified service agency is responsible for the proper installation of this kit. The installation is not proper and complete until the operation of the converted appliance is checked as specified in the manufacturer’s instructions supplied with the kit.
Cet équipement de conversion sera installé par une agence qualifiée de service conformément aux instructions du fabricant et toutes exigences et codes applicables de l’autorisés avoir la juridiction. Si l’information dans cette Instruction n’est pas suivie exactement, un feu, explosion ou production de protoxyde de carbone peut résulter le dommages causer de propriété, pert ou blessure personnelle de vie. L’agence qualifiée do service est esponsable de l’installation propre de cet équipemetn. L’installation n’est pas propre et complète jusqu’à l’operation de l’appareil converi est chéque suivant les critères établis dans les instruction de propriétaire provision nées avel l’équipement.
Kit 157785- LP to NG
CAUTION: Before proceeding with this conversion, the gas supply must be shut off prior to disconnecting the electrical power.
Jøtul North America, Inc. 55 Hutcherson Dr. Gorham, Maine 04038
ATTENTION: Avant de procéder à cette conversion, l’approvisionnement en gaz doit être coupée avant de dé­brancher l’alimentation électrique.
2 / 17 139777_R02
Fuel Conversion
The Jøtul GI 535 DV IPI is shipped from the factory equipped to burn Natural gas. Propane Fuel Conversion Kit 157784 is included with this appliance. Use Fuel Conversion Kit 157785 to convert back to Natural Gas. The kits contain all the necessary components, including labels that must be applied to the insert.
WARNING:
THE CONVERSION KIT IS TO BE INSTALLED BY AN AUTHORIZED JØTUL SERVICE TECHNICIAN IN ACCORDANCE WITH THE MANUFACTURER’S INSTRUCTION AND ALL CODES AND REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN SERIOUS INJURY OR PROPERTY DAMAGE. THE QUALIFIED AGENCY PERFORMING THIS WORK ASSUMES RESPONSIBILITY FOR THIS CONVERSION.
IN CANADA:
THE CONVERSION SHALL BE CARRIED OUT IN ACCORDANCE WITH THE REQUIREMENTS OF THE PROVINCIAL AUTHORITIES HAVING JURISDICTION AND IN ACCORDANCE WITH THE REQUIREMENTS OF
THE CAN1-B149.1 AND .2 INSTALLATION CODE.
Fuel Conversion Kit Propane #157784 / Natural Gas #157785
SIT Proflame 2 Valve Rating Specifications - BTU/hr NG LP
Min. Input Rate, 0 - 2000 ft. 32,000 31,500 Max. Input Rate, 0 - 2000 ft. 11,500 11,000
Tools required:
• Torx T20 or slotted screwdriver
• ratchet wrench w/ 10 mm or 7/16” deep-well socket
• 1/2” open ended wrench or deep-well socket
Conversion Kit Contents:
• 1, Regulator Tower labeled for either LP or NG
• 2, Regulator Tower screws
• 2, Burner Orifices: Propane - Left - 3/64”
- Right - #56
Natural Gas - Left - 1.95 mm
- Right - #48
• Label A - to be completed and applied to the back of the stove.
• Label B - apply to the stove’s Rating Plate
• Small valve label - apply to valve body
• Conversion instructions
• Fuel Conversion Label A - Valve Compartment
• Fuel Conversion Label B - Rating Plate Notice
• Small Regulator Tower Label
Fuel Conversion Procedure
1. Use the Latch Tool to shut off the gas supply by closing the gas cock. Fig. 1.
2. Disconnect electrical power from the appliance.
3. Use the Latch Tool to remove disengage and remove the glass frame from the firebox.
3. RETRACT THE AIR SHUTTERS: Locate the Air Shutter cable on the floor in each side compartment - push each fully in. This action retracts the shutters and allows the burner to be disengaged from the firebox. See figs. 2 and 3.
4. REMOVE THE BURNER: Lift out the two steel support shelves, fig. 4, (A), located at each side of the burner. Grasp the burner assembly at the sides, lifting it straight up, then tilt it back to disengage it from the injectors and front locator studs (B). Pull the assembly up out of the firebox.
5. CHANGE THE BURNER INJECTORS: Use a 1/2” open end wrench or deep-well socket to remove the burner injectors from the brass fittings at the rear of the firebox. See fig.
2. Install the injectors from this conversion kit into the appropriate left and right locations and tighten securely.
6. CHANGE THE INTEGRATED DUAL-FUEL PILOT ORIFICE: Use the 7/16” wrench to loosen the pilot head just enough to push the orifice lever to the appropriate position. See fig. 5.
LP : push lever to the Right to expose the red indicator. NG: push lever to the Left.
Retighten the pilot base nut, but do not over-tighten. Be
certain the pilot hood directs flame to the flame sensor.
7. LP CONVERSION ONLY: Remove the Upper Baffle Wing from the firebox. See fig. 6.
• Remove three 10 mm hex nuts (A) from the front of the Upper Baffle plate.
• Loosen, but do not remove the two 10 mm hex nuts (B) from the rear of the Upper Baffle plate. These are not visible, but you will be able to locate them with your fingers. The baffle plate will drop down enough to enable you to remove the Inner Wing panel from the firebox.
• Remove the two sheet metal screws (C) that secure the Inner Baffle Wing to the center of the Upper Baffle.
• Replace the three front hex nuts on the Upper Baffle and re-tighten the rear nuts.
8. CHANGE THE VARIABLE REGULATOR TOWER on the gas control valve. See fig. 3.
• Remove the heat shield from the valve compartment to access the Regulator Tower.
• Disconnect the IFC lead from the regulator lead.
• Remove the two Torx screws to remove the original regulator tower, rubber diaphragm and spring.
• Install the new regulator tower from the kit using the screws previously removed. Tighten screws securely. Reconnect the Regulator lead to the IFC lead.
2