80 PLUS Verification and Testing Report
TYPICAL EFFICIENCY (50% Load):
AVERAGE EFFICIENCY :
80 PLUS COMPLIANT:
Ecos ID #
Manufacturer
Model Number
Serial Number
Year
Type
Test Date
Input Voltage
Input Current
Input Frequency
Note: All measurements were taken with input voltage at 115 V nominal at 60 Hz. Input AC Current Waveform (ITHD = 0.45%, 50% Load)
I
Rated Output Power
RMS A
PF
A
0.80 0.98 12.72% 10% 89.47 12.12/0.04 3.4/1.04 5.05/1.04 5.14/0.22 76.85
1.49 0.99 4.22% 20% 170.70 12.12/0.09 3.39/2.08 5.04/2.07 5.13/0.43 153.89
3.68 1.00 0.45% 50% 421.60 12.13/0.22 3.38/5.2 5.03/5.17 5.1/1.08 384.45
7.53 0.99 7.81% 100% 861.10 12.17/0.43 3.36/10.38 5.01/10.32 5.05/2.16 763.91
1000
900
800
700
600
500
400
300
Power (Watts)
200
100
0
20% 50% 100%
4512
1STPLAYER TECHNOLOGY (GUANGZHOU)
PS-750SP
N/A
2015
ATX12V
12/21/15
100-240 Volts
I
(%)
Load (%)
THD
Input and Output Power
Input Watts
Loading (% of Rated Output Power)
Input
Watts
Output Watts
12V (cumulative of 12V1, 12V2, etc.)
7.5-15 Amps
50-60 Hz
12.29/5.41
12.29/10.83
12.28/27.09
12.24/54.04
200
150
100
50
0
0 0.003 0.006 0.009 0.012 0.015
-50
-100
Voltage (V)
-150
-200
DC Terminal Voltage (V)/ DC Load Current (A)
100%
90%
80%
70%
60%
50%
40%
30%
Efficiency (%)
20%
10%
0%
Input Current and Voltage Waveforms
0% 25% 50% 75% 100% 125%
Loading (% of Rated Output Power)
Time (s)
Voltage Current
Efficiency of the Power Supply
Output
Watts
Efficiency %
6
4
2
0
-2
Current (A)
-4
-6
Efficiency
%
85.89%
90.16%
91.19%
88.71%
These tests were conducted by a third party independent testing firm on behalf of the
80 PLUS Program. 80 PLUS is a certification program to promote highly-efficient power
supplies (greater than 80% efficiency in the active mode) in technology applications.
http://www.80plus.org/