MUR840, MUR860, RURP840, RURP860
Data Sheet January 2000
8A, 400V - 600V Ultrafast Diodes
The MUR840, MUR860, RURP840 and RURP860 are low
forward voltage drop ultrafast recovery rectifiers
(t
< 60ns). They use a glass-passivated ion-implanted,
rr
epitaxial construction.
These devices are intended for use as output rectifiers and
flywheel diodes in a variety of high-frequency pulse-width
modulated switching regulators.Theirlowstoredchargeand
attendant fast reverse-recovery behavior minimize electrical
noise generation and in many circuits markedly reduce the
turn-on dissipation of the associated power switching
transistors.
Formerly developmental type TA09616.
Ordering Information
PART NUMBER PACKAGE BRAND
MUR840 TO-220AC MUR840
RURP840 TO-220AC RURP840
MUR860 TO-220AC MUR860
RURP860 TO-220AC RURP860
NOTE: When ordering, use the entire part number.
File Number 2091.4
Features
• Ultrafast with Soft Recovery . . . . . . . . . . . . . . . . . . .<60ns
• Operating Temperature. . . . . . . . . . . . . . . . . . . . . . .175
o
• Reverse Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . .600V
• Avalanche Energy Rated
• Planar Construction
Applications
• Switching Power Supplies
• Power Switching Circuits
• General Purpose
Packaging
JEDEC TO-220AC
ANODE
CATHODE
(FLANGE)
CATHODE
C
Symbol
K
A
Absolute Maximum Ratings T
Peak Repetitive Reverse Voltage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V
Working Peak Reverse Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V
DC Blocking Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V
Average Rectified Forward Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .I
(TC = 155oC)
Repetitive Peak Surge Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I
(Square Wave, 20kHz)
Nonrepetitive Peak Surge Current. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I
(Halfwave, 1 Phase, 60Hz)
Maximum Power Dissipation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .P
Avalanche Energy (See Figures 10 and 11) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E
Operating and Storage Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . T
Maximum Lead Temperature for Soldering
Leads at 0.063 in. (1.6mm) from case for 10s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . T
Package Body for 10s, see Tech Brief 334. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .T
= 25oC, Unless Otherwise Specified
C
RRM
RWM
F(AV)
FRM
FSM
STG
PKG
MUR840
RURP840
400 600 V
400 600 V
R
D
AVL
, TJ-65 to 175 -65 to 175
400 600 V
88A
16 16 A
100 100 A
75 75 W
20 20 mJ
300 300
L
260 260
MUR860
RURP860 UNITS
o
C
o
C
o
C
1
1-888-INTERSIL or 321-724-7143 | Copyright © Intersil Corporation 2000
MUR840, MUR860, RURP840, RURP860
Electrical Specifications T
= 25oC, Unless Otherwise Specified
C
MUR840, RURP840 MUR860, RURP860
SYMBOL TEST CONDITION
V
F
IF = 8A - - 1.3 - - 1.5 V
IF = 8A, TC = 150oC - - 1.0 - - 1.2 V
I
R
VR = 400V - - 100 - - - µA
VR = 600V -----100µA
VR = 400V, TC = 150oC - - 500 - - - µA
VR = 600V, TC = 150oC -----500µA
t
rr
IF = 1A, dIF/dt = 200A/µs - -60- -60ns
IF = 8A, dIF/dt = 200A/µs - -70- -70ns
t
a
t
b
Q
RR
C
J
R
θJC
IF = 8A, dIF/dt = 200A/µs - 32 - - 32 - ns
IF = 8A, dIF/dt = 200A/µs - 21 - - 21 - ns
IF = 8A, dIF/dt = 200A/µs - 195 - - 195 - nC
VR = 10V, IF = 0A - 25 - - 25 - pF
--2--2oC/W
DEFINITIONS
VF = Instantaneous forward voltage (pw = 300µs, D = 2%).
IR = Instantaneous reverse current.
trr = Reverse recovery time (See Figure 9), summation of ta + tb.
ta = Time to reach peak reverse current (See Figure 9).
tb = Time from peak IRM to projected zero crossing of IRM based on a straight line from peak IRM through 25% of IRM (See Figure 9).
QRR = Reverse recovery charge.
CJ = Junction Capacitance.
R
= Thermal resistance junction to case.
θJC
pw = pulse width.
D = duty cycle.
UNITSMIN TYP MAX MIN TYP MAX
Typical Performance Curves
40
10
100oC
, FORWARD CURRENT (A)
F
I
1
0.5
0
175oC
0.5
25oC
1
VF, FORWARD VOLTAGE (V)
1.5
2
2.5
FIGURE 1. FORWARD CURRENT vs FORWARD VOLTAGE FIGURE 2. REVERSE CURRENT vs REVERSE VOLTAGE
2
500
100
10
1
, REVERSE CURRENT (µA)
0.1
R
I
0.01
0 200 400 600300 500
100
VR, REVERSE VOLTAGE (V)
175oC
100oC
25oC