RHRG3040CC, RHRG3060CC
Data Sheet January 2000 File Number 3939.3
30A, 400V - 600V Hyperfast Dual Diodes
The RHRG3040CC and RHRG3060CC are hyperfast diodes
with soft recovery characteristics (t
< 40ns). They havehalf
rr
the recovery time of ultrafast diodes and are silicon nitride
passivated ion-implanted epitaxial planar construction.
These devices are intended for use as freewheeling/
clamping diodes and rectifiersinavariety of switching power
supplies and other power switching applications. Their low
stored charge and hyperfast soft recovery minimize ringing
and electrical noise in many power switching circuits, thus
reducing power loss in the switching transistors.
Formerly developmental type TA49063.
Ordering Information
PART NUMBER PACKAGE BRAND
RHRG3040CC TO-247 RHRG3040C
RHRG3060CC TO-247 RHRG3060C
NOTE: When ordering, use the entire part number.
Symbol
K
Features
• Hyperfast with Soft Recovery. . . . . . . . . . . . . . . . . .<40ns
• Operating Temperature. . . . . . . . . . . . . . . . . . . . . . .175
o
• Reverse Voltage Up To. . . . . . . . . . . . . . . . . . . . . . . .600V
• Avalanche Energy Rated
• Planar Construction
Applications
• Switching Power Supplies
• Power Switching Circuits
• General Purpose
Packaging
JEDEC STYLE TO-247
ANODE 2
CATHODE
(BOTTOM
SIDE METAL)
CATHODE
ANODE 1
C
A
1
Absolute Maximum Ratings (Per Leg) T
Peak Repetitive Reverse Voltage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V
Working Peak Reverse Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V
DC Blocking Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V
Average Rectified Forward Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I
(TC = 120oC)
Repetitive Peak Surge Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .I
(Square Wave, 20kHz)
Nonrepetitive Peak Surge Current. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .I
(Halfwave, 1 Phase, 60Hz)
Maximum Power Dissipation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .P
Avalanche Energy (See Figures 10 and 11) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .E
Operating and Storage Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . T
A
2
= 25oC, Unless Otherwise Specified
C
RRM
RWM
F(AV)
FRM
FSM
AVL
, T
STG
RHRG3040CC RHRG3060CC UNITS
400 600 V
400 600 V
R
D
J
400 600 V
30 30 A
70 70 A
325 325 A
125 125 W
20 20 mJ
-65 to 175 -65 to 175
o
C
3-1
1-888-INTERSIL or 321-724-7143 | Copyright © Intersil Corporation 2000
RHRG3040CC, RHRG3060CC
Electrical Specifications (Per Leg) T
= 25oC, Unless Otherwise Specified
C
RHRG3040CC RHRG3060CC
SYMBOL TEST CONDITION
V
F
IF = 30A - - 2.1 - - 2.1 V
IF = 30A, TC = 150oC - - 1.7 - - 1.7 V
I
R
VR = 400V - - 250 - - - µA
VR = 600V - - - - - 250 µA
VR = 400V, TC = 150oC - - 1.0 - - - mA
VR = 600V, TC = 150oC - - - - - 1.0 mA
t
rr
IF = 1A, dIF/dt = 200A/µs--40--40ns
IF = 30A, dIF/dt = 200A/µs--45--45ns
t
a
t
b
Q
RR
C
J
R
θJC
IF = 30A, dIF/dt = 200A/µs - 22 - - 22 - ns
IF = 30A, dIF/dt = 200A/µs - 18 - - 18 - ns
IF = 30A, dIF/dt = 200A/µs - 100 - - 100 - nC
VR = 10V, IF = 0A - 85 - - 85 - pF
- - 1.2 - - 1.2
DEFINITIONS
VF = Instantaneous forward voltage (pw = 300µs, D = 2%).
IR = Instantaneous reverse current.
trr= Reverse recovery time (See Figure 9), summation of ta+tb.
ta = Time to reach peak reverse current (See Figure 9).
tb = Time from peak IRM to projected zero crossing of IRM based on a straight line from peak IRM through 25% of IRM (See Figure 9).
QRR = Reverse recovery charge.
CJ = Junction Capacitance.
R
= Thermal resistance junction to case.
θJC
pw = pulse width.
D = duty cycle.
UNITSMIN TYP MAX MIN TYP MAX
o
C/W
Typical Performance Curves
300
100
100oC
10
, FORWARD CURRENT (A)
F
I
175oC
1
012
25oC
34
VF, FORWARD VOLTAGE (V)
FIGURE 1. FORWARD CURRENT vs FORWARD VOLTAGE FIGURE 2. REVERSE CURRENT vs REVERSE VOLTAGE
3-2
2000
175oC
100
10
1
, REVERSE CURRENT (µA)
0.1
R
I
0.01
0 200 400 600300 500
100
VR, REVERSE VOLTAGE (V)
100oC
25oC