Intersil Corporation HS-26CT32RH-T Datasheet

HS-26CT32RH-T
Data Sheet July 1999 File Number
Radiation Hardened Quad Differential Line Receiver
Intersil’sSatellite Applications FlowTM(SAF) devices are fully tested and guaranteed to 100kRAD total dose. These QML Class T devices are processed to a standard flow intended to meet the cost and shorter lead-time needs of large volume satellite manufacturers, while maintaining a high level of reliability.
The Intersil HS-26CT32RH-T is a Quad Differential Line Receiver designed for digital data transmission over balanced lines and meets the requirements of EIA Standard RS-422. Radiation Hardened CMOS processing assures low power consumption, high speed, and reliable operation in the most severe radiation environments.
The HS-26CT32RH-T has an input sensitivity of 200mV (typ.) over the common mode input voltage r ange of±7V. The receivers are also equipped with input fail saf e circuitry, which causes the outputs to go to a logic “1” when the inputs are open. TTL compatible Enable and Disable functions are common to all four receivers.
Specifications
Specifications for Rad Hard QML devices are controlled by the Defense Supply Center in Columbus (DSCC). The SMD numbers listed below must be used when ordering.
Detailed Electrical Specifications for the HS-26CT32RH-T are contained in SMD 5962-95631. A “hot-link” is provided from our website for downloading. www.intersil.com/spacedefense/ne wsafc lasst.asp
4593.1
Features
• QML Class T, Per MIL-PRF-38535
• Radiation Performance
5
- Gamma Dose . . . . . . . . . . . . . . . . . . . . 1 x 10
RAD(Si)
- SEU and SEL . . . . . . . . . . Immune to 100MeV/mg/cm
• EIA RS-422 Compatible Inputs
• TTL Compatible Enable Inputs
• Input Fail Safe Circuitry
• High Impedance Inputs when Disabled or Powered Down
• Low Power Dissipation 138mW Standby (Max)
• Single 5V Supply
o
• Full -55
C to 125oC Military Temperature Range
Pinouts
HS1-26CT32RH-T (SBDIP) CDIP2-T16
TOP VIEW
16 15 14 13 12 11 10
9
V
BIN BIN BOUT ENABLE DOUT DIN DIN
AIN AIN
AOUT
ENABLE
COUT
CIN CIN
GND
1 2 3 4 5 6 7 8
2
Intersil’s Quality Management Plan (QM Plan), listing all Class T screening operations, is also available on our website.
www.intersil.com/quality/manuals.asp
Ordering Information
ORDERING
NUMBER
5962R9563101TEC HS1-26CT32RH-T -55 to 125 HS1-26CT32RH/Proto HS1-26CT32RH/Proto -55 to 125 5962R9563101TXC HS9-26CT32RH-T -55 to 125 HS9-26CT32RH/Proto HS9-26CT32RH/Proto -55 to 125
NOTE:
Minimumorderquantity for -T is 150 units through
distribution, or 450 units direct.
PART
NUMBER
1
TEMP.
RANGE (oC)
CAUTION: These devices are sensitive to electrostatic discharge; follow proper IC Handling Procedures.
HS9-26CT32RH-T (FLATPACK), CDFP4-F16
TOP VIEW
AIN AIN
AOUT
ENABLE
COUT
CIN CIN
GND
www.intersil.com or 407-727-9207 | Copyright © Intersil Corporation 1999
Satellite Applications Flow™ (SAF) is a trademark of Intersil Corporation.
116 2 3 4 5 6 7 8
15 14 13 12 11 10
9
V
BIN BIN BOUT ENABLE DOUT DIN DIN
Functional Diagram
HS-26CT32RH-T
ENABLE ENABLE
DEVICE POWER
ON/OFF
ON 0 1 X HI-Z
ON 1 X VID VTH (Max) 1
ON 1 X VID VTH (Min) 0
ON X 0 VID VTH (Max) 1
DIN CIN CIN BIN BIN AIN AIN
DIN
DOUT
TRUTH TABLE
INPUTS OUTPUT
ENABLE ENABLE INPUT OUT
+-+-+-+-
AOUTBOUTCOUT
ON X 0 VID VTH (Min) 0
ON 1 X Open 1
ON X 0 Open 1
2
Loading...