HCTS160T
Data Sheet July 1999 File Number
Radiation Hardened Synchronous
Counter
Intersil’sSatellite Applications FlowTM(SAF) devices are fully
tested and guaranteed to 100kRAD total dose. These QML
Class T devices are processed to a standard flow intended
to meet the cost and shorter lead-time needs of large
volume satellite manufacturers, while maintaining a high
level of reliability.
The Intersil HCTS160T is a Radiation Hardened High Speed
Presettable BCD Decade Synchronous Counter that
features an asynchronous reset and look-ahead carry logic.
Counting and parallel presetting are accomplished
synchronously with the low-to-high transition of the clock. A
low level on the synchronous parallel enable input,
SPE,
disables counting and allows data at the preset inputs, P0 P3, to be loaded into the counter. The counter is reset by a
low on the master reset input,
MR. Two count enables, PE
and TE are providedfor n-bit cascading. TE also controls the
terminal count output, TC. The terminal count output
indicates a maximum count for one clock pulse and is used
to enable the next cascaded stage to count.
Specifications
Specifications for Rad Hard QML devices are controlled by
the Defense Supply Center in Columbus (DSCC). The SMD
numbers listed below must be used when ordering.
Detailed Electrical Specifications for the HCTS160T are
contained in SMD 5962-95742. A “hot-link” is provided from
our website for downloading.
www.intersil.com/spacedefense/ne wsafc lasst.asp
Intersil‘s Quality Management Plan (QM Plan), listing all
Class T screening operations, is also available on our
website.
www.intersil.com/quality/manuals.asp
4626.1
Features
• QML Class T, Per MIL-PRF-38535
• Radiation Performance
5
- Gamma Dose (γ) 1 x 10
RAD(Si)
- Latch-Up Free Under Any Conditions
- SEP Effective LET No Upsets: >100 MEV-cm
- Single Event Upset (SEU) Immunity < 2 x 10
2
/mg
-9
Errors/Bit-Day (Typ)
• 3 Micron Radiation Hardened SOS CMOS
• Fanout (Over Temperature Range)
- Standard Outputs 10 LSTTL Loads
• Significant Power Reduction Compared to LSTTL ICs
• DC Operating Voltage Range: 4.5V to 5.5V
• LSTTL Input Compatibility
-V
= 0.8V Max
IL
-V
= V
IH
• Input Current Levels Ii ≤ 5mA at V
CC/2
Min
OL
, V
OH
Pinouts
HCTS160DTR (SBDIP), CDIP2-T16
TOP VIEW
16
MR
CP
P0
P1
P2
P3
PE
GND
1
2
3
4
5
6
7
8
V
CC
15
TC
14
Q0
13
Q1
12
Q2
Q3
11
10
TE
9
SPE
Ordering Information
TEMP.
ORDERING
NUMBER PART NUMBER
5962R9574201TEC HCTS160DTR -55 to 125
5962R9574201TXC HCTS160KTR -55 to 125
NOTE:
Minimumorderquantity for -T is 150 units through
distribution, or 450 units direct.
1
RANGE
(oC)
CAUTION: These devices are sensitive to electrostatic discharge; follow proper IC Handling Procedures.
HCTS160KTR (FLATPACK), CDFP4-F16
TOP VIEW
MR
CP
P0
P1
P2
P3
PE
GND
www.intersil.com or 407-727-9207
Satellite Applications Flow™ (SAF) is a trademark of Intersil Corporation.
116
2
3
4
5
6
7
8
15
14
13
12
11
10
9
| Copyright © Intersil Corporation 1999
V
CC
TC
Q0
Q1
Q2
Q3
TE
SPE
Functional Diagram
HCTS160T
SPE
MR
CP
PE
TE
3456
Q2 Q3
Q0 Q1
MR
D2
T2
CP
Q2
P
Q0Q1Q2
Q0 Q3
GND V
CC
MR
D0
T0
CP
Q3 Q0 Q3 Q0
P
Q0
Q0
MR
D1
T1
CP
P
Q1
P3P2P1P0
Q3
Q0
P
Q3 Q3
MR
D3
T3
CP
168
14 15
Q0
TC
Q1
13
Q0
12
11
Q1
TRUTH TABLE
INPUTS OUTPUTS
OPERATING MODE
MR CP PE TE SPE Pn Qn TC
Reset (Clear) L X X X X X L L
Parallel Load H X X l l L L
H X X l h H (Note 1)
Count H h h h (Note 3) X Count (Note 1)
Inhibit H X l (Note 2) X h (Note 3) X qn (Note 1)
H X X l (Note 2) h (Note 3) X qn L
H = HIGH voltage level.
L = LOW voltage level.
h = HIGH voltage level one setup time prior to the LOW-to-HIGH clock transition.
l = LOW voltage level one setup time prior to the LOW-to-HIGH clock transition.
X = Immaterial.
q = Lower case letter indicate the state of the referenced output prior to the LOW-to-HIGH clock transition.
= LOW-to-HIGH clock transition.
NOTES:
1. The TC output is HIGH when TE is HIGH and the counter is at terminal count (HHHH for 161 and HLLH for 160).
2. The HIGH-to-LOW transition of PE or TE on the 54/74161 and 54/74160 should only occur while CP is high for conventional operation.
3. The LOW-to-HIGH transition of SPE on the 54/74161 and 54/74160 should only occur while CP is high for conventional operation.