• Compatible with Worldwide PBX and CO Performance
Requirements
• Controlled Supply of Battery Feed Current with Programmable
Current Limi t
• Operates with 5V Positive Supply (V
• Internal Ring Relay Driver and a Utility Relay Driver
B+
)
• High Impedance Mode for Subscriber Loop
• High Temper at ure Alarm Ou tput
• Low Power Consumption During Standby Functions
• Switch Hook, Ground Key, and Ring Trip Detection
• Selective Power Denial to Subscr iber
• Voice Path Active During Power Denial
• On Chip Op-Amp for 2 Wire Im pedance Mat c hing
Applications
• Solid State Line I nterface Circuit for PBX or Ce ntral Office
Systems, Digital Loop Carrier Systems
• Hote l/Motel Switching Systems
• Direct Inward Dialing (DID) Trunks
• Voice Messaging PBX’s
• High Voltage 2W/4W, 4W/2W Hybrid
S
N
G
I
S
E
C
c
.
l
t
a
r
e
t
n
e
c
s
t
/
m
o
HC-5509A1
SLIC
Subscriber Line Interface Circuit
Description
The HC-5509A1 telephone Subscriber Line Interface Circuit
integrates most of the BORSCHT functions on a monolithic
IC. The device is manufactured in a Dielectric Isolation (DI)
process and is designed for use as a high voltage interface
between the traditional telephone subscriber pair (Tip and
Ring) and the low voltage filter ing and coding/decoding functions of the line card. Together with a secondary protection
diode bridge and “feed” resistors, the device will withstand
1000V lightning induced surges, in plastic packages. The
SLIC also maintains specified transmission performance in
the presence of ex ternally induced longi tudinal currents. The
BORSCHT functions that the SLIC provides are:
• Battery Feed with Subscriber Loop Current Limiting
In addition, the SLIC provides selective denial of power to
subscriber loops, a programmable subscriber loop current
limit from 20 to 60mA, a thermal shutdo wn with an alarm output and line fault protection. Switch hook detection, ring trip
detection and ground key detection functions are also incorporated in the SLIC devic e.
The HC-5509A1 SLIC is ideally suited for line card designs
in PBX and CO systems, replacing traditional transformer
solutions.
CAUTION: Stresses above those listed in “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress only rating and operation
of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied.
Electrical SpecificationsUnless Otherwise Specified, Typical Parameters are at TA = +25oC, Min-Max Parameters are over
Operating Temperature Range, V
speci fie d at 600Ω 2-Wire terminating impedance.
= -48V, VB+ = +5V, AG = DG = BG = 0V. All A.C. Parameters are
B-
PARAMETERTEST CONDITIONSMINTYPMAXUNITS
A.C. TRANSMISSION PARAMETERS
RX Input Impedance300Hz to 3.4kHz (Note 3)-100-kΩ
TX Output Imped ance300Hz to 3.4kHz (Note 3)--20Ω
4W Input Overload Level300Hz to 3.4kHz R
= 1200Ω,
L
+1.5--V
PEAK
600Ω Reference
2W Return LossMatched for 600Ω (Note 3)
SRL LO2635-dB
ERL3040-dB
SRL HI3040-dB
2W Longitudinal to Metallic Balance
Off Hook
4W Longitudinal Balance
Per ANSI/IEEE STD 455-1976 (Note 3)
5863-dB
300Hz to 3400Hz
300Hz to 3400Hz (Note 3)5055-dB
Off Hook
Low Frequency Longitudinal BalanceR.E.A. Test Circuit---67dBmp