Intersil Corporation FSYA250R, FSYA250D Datasheet

June 1998
FSYA250D,
FSYA250R
27A, 200V, 0.100 Ohm, Rad Hard,
SEGR Resistant, N-Channel Power MOSFETs
Features
• 27A, 200V, r
• Total Dose
- Meets Pre-RAD Specifications to 100K RAD (Si)
• Single Event
- Safe Operating Area Curve for Single Event Effects
- SEE Immunity for LET of 36MeV/mg/cm V
up to 80% of Rated Breakdown and
DS
V
of 10V Off-Bias
GS
• Dose Rate
- Typically Survives 3E9 RAD (Si)/s at 80% BV
- Typically Survives 2E12 if Current Limited to I
• Photo Current
- 12nA Per-RAD(Si)/s Typically
• Neutron
- Maintain Pre-RAD Specifications for 1E13 Neutrons/cm
- Usable to 1E14 Neutrons/cm
DS(ON)
2
2
with
DSS
DM
2
Ordering Information
RAD LEVEL SCREENING LEVEL PART NUMBER/BRAND
10K Commercial FSYA250D1 10K TXV FSYA250D3 100K Commercial FSYA250R1 100K TXV FSYA250R3 100K Space FSYA250R4
Description
The Discrete Products Operation of Intersil Corporation has developed a series of Radiation Hardened MOSFETs specif­ically designed for commercial and military space applica­tions. Enhanced Power MOSFET immunity to Single Event Effects (SEE), Single Event Gate Rupture (SEGR) in particu­lar, is combined with 100K RADS of total dose hardness to provide devices which are ideally suited to harsh space envi­ronments. The dose rate and neutron tolerance necessary for military applications have not been sacrificed.
The Intersil portfolio of SEGR resistant radiation hardened MOSFETs includes N-Channel and P-Channel devices in a variety of voltage, current and on-resistance ratings. Numerous packaging options are also available.
This MOSFET is an enhancement-mode silicon-gate power field-effect transistor of the vertical DMOS (VDMOS) struc­ture. It is specially designed and processed to be radiation tolerant. The MOSFET is well suited for applications exposed to radiation environments such as switching regula­tion, switching converters, motor drives, relay drivers and drivers for high-power bipolar switching transistors requiring high speed and low gate drive power. This type can be oper­ated directly from integrated circuits.
Reliability screening is available as either commercial, TXV equivalent of MIL-S-19500, or Space equivalent of MIL-S-19500. Contact Intersil for any desired deviations from the data sheet.
Symbol
D
G
Formerly available as type TA17657.
Package
SMD1
CAUTION: These devices are sensitive to electrostatic discharge; follow proper IC Handling Procedures. http://www.intersil.com or 407-727-9207
| Copyright © Intersil Corporation 1999
3-125
S
File Number 4313.1
FSYA250D, FSYA250R
Absolute Maximum Ratings T
= 25oC, Unless Otherwise Specified
C
FSYA250D,
FSYA250R UNITS
Drain to Source Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V
Drain to Gate Voltage (RGS = 20k) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V
DS
DGR
200 V 200 V
Continuous Drain Current
TC = 25oC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I
TC = 100oC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I
Pulsed Drain Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I
Gate to Source Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V
D D
DM
GS
27 A 17 A 81 A
±20 V
Maximum Power Dissipation
TC = 25oC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .P
TC = 100oC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .P
T T
150 W
60 W
Linear Derating Factor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.20 W/oC
Single Pulsed Avalanche Current, L = 100µH, (See Test Figure). . . . . . . . . . . . . . . . . . . . . . I
Continuous Source Current (Body Diode) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I
Pulsed Source Current (Body Diode). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I
Operating and Storage Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .TJ, T
STG
Lead Temperature (During Soldering) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . T
AS
S
SM
L
81 A 27 A 81 A
-55 to 150 300
o
C
o
C
(Distance >0.063in (1.6mm) from Case, 10s Max)
CAUTION: Stresses above those listed in “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress only rating and operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied.
Electrical Specifications T
= 25oC, Unless Otherwise Specified
C
PARAMETER SYMBOL TEST CONDITIONS MIN TYP MAX UNITS
Drain to Source Breakdown Voltage BV Gate Threshold Voltage V
DSSID
GS(TH)VGS
= 1mA, VGS = 0V 200 - - V
= VDS,
ID = 1mA
TC = -55oC - - 5.0 V TC = 25oC 1.5 - 4.0 V TC = 125oC 0.5 - - V
Zero Gate Voltage Drain Current I
Gate to Source Leakage Current I
DSS
GSS
VDS = 160V, VGS = 0V
TC = 25oC--25µA TC = 125oC - - 250 µA
VGS = ±20V TC = 25oC - - 100 nA
TC = 125oC - 200 nA Drain to Source On-State Voltage V Drain to Source On Resistance r
Turn-On Delay Time t
DS(ON)VGS
DS(ON)12ID
d(ON)
Rise Time t Turn-Off Delay Time t
d(OFF)
Fall Time t Total Gate Charge Q
g(TOT)VGS
Gate Charge at 12V Q Threshold Gate Charge Q Gate Charge Source Q Gate Charge Drain Q Plateau Voltage V
(PLATEAU)ID
Input Capacitance C Output Capacitance C Reverse Transfer Capacitance C Thermal Resistance Junction to Case R
r
f
g(12)
g(TH)
gs
gd
ISS OSS RSS
JC
θ
= 12V, ID = 27A - 2.84 V
= 17A,
VGS = 12V
VDD = 100V, ID = 27A, RL = 3.70, VGS 12V, RGS = 2.35
TC = 25oC - 0.080 0.100 TC = 125oC - - 0.182
- - 45 ns
- - 110 ns
- - 90 ns
- - 25 ns
= 0V to 20V VDD = 100V,
VGS = 0V to 12V - 130 150 nC
ID = 27A
- - 230 nC
VGS = 0V to 2V - - 11 nC
-2640nC
-6578nC
= 27A, VDS = 15V - 8 - V
VDS = 25V, VGS = 0V, f = 1MHz
- 3200 - pF
- 625 - pF
- 170 - pF
- - 0.83
o
C/W
3-126
Source to Drain Diode Specifications
PARAMETER SYMBOL TEST CONDITIONS MIN TYP MAX UNITS
FSYA250D, FSYA250R
Forward Voltage V Reverse Recovery Time t
SD
rr
Electrical Specifications up to 100K RAD T
ISD = 27A 0.6 - 1.8 V ISD = 27A, dISD/dt = 100A/µs - - 550 ns
= 25oC, Unless Otherwise Specified
C
PARAMETER SYMBOL TEST CONDITIONS MIN MAX UNITS
Drain to Source Breakdown Volts (Note 3) BV Gate to Source Threshold Volts (Note 3) V Gate to Body Leakage (Notes 2, 3) I Zero Gate Leakage (Note 3) I Drain to Source On-State Volts (Notes 1, 3) V Drain to Source On Resistance (Notes 1, 3) r
DS(ON)
DS(ON)12VGS
DSS
GS(TH)
GSS DSS
VGS = 0, ID = 1mA 200 - V VGS = VDS, ID = 1mA 1.5 4.0 V VGS = ±20V, VDS = 0V - 100 nA VGS = 0, VDS = 160V - 25 µA VGS = 12V, ID = 27A - 2.84 V
= 12V, ID = 17A - 0.100
NOTES:
1. Pulse test, 300µs Max.
2. Absolute value.
3. Insitu Gamma bias must be sampled for both VGS = 12V, VDS = 0V and VGS = 0V, VDS = 80% BV
DSS
.
Single Event Effects (SEB, SEGR) (Note 4)
ENVIRONMENT (NOTE 5)
APPLIED
VGS BIAS
TEST SYMBOL
Single Event Effects Safe Operating Area
ION
SPECIES
SEESOA Ni 26 43 -20 200
Br 37 36 -5 200
TYPICAL LET (MeV/mg/cm)
TYPICAL
RANGE (µ)
Br 37 36 -10 160 Br 37 36 -15 100 Br 37 36 -20 40
NOTES:
4. Testing conducted at Brookhaven National Labs; sponsored by Naval Surface Warfare Center (NSWC), Crane, IN.
5. Fluence = 1E5 ions/cm2 (typical), T = 25oC.
6. Does not exhibit Single Event Burnout (SEB) or Single Event Gate Rupture (SEGR).
(V)
(NOTE 6)
MAXIMUM
VDS BIAS
(V)
Typical Performance Curves
LET = 26MeV/mg/cm LET = 37MeV/mg/cm2, RANGE = 36µ
FLUENCE = 1E5 IONS/cm2 (TYPICAL)
200
160
120
(V)
DS
V
80
40
TEMP = 25oC
0
0 -10
-5 V
(V)
GS
Unless Otherwise Specified
2
, RANGE = 43µ
-15
-20 -25
LIMITING INDUCTANCE (HENRY)
1E-3
1E-4
1E-5
1E-6
1E-7
30
DRAIN SUPPLY (V)
ILM = 10A
30A
100A
300A
30010010
FIGURE 1. SINGLE EVENT EFFECTS SAFE OPERATING AREA FIGURE 2. DRAIN INDUCTANCE REQUIRED TO LIMIT
GAMMA DOT CURRENT TO I
AS
3-127
1000
Loading...