Intersil Corporation FSL13A0R, FSL13A0D Datasheet

FSL13A0D, FSL13A0R
Data Sheet June 1999
9A, 100V, 0.180 Ohm, Rad Hard, SEGR Resistant, N-Channel Power MOSFETs
The Discrete Products Operation of Intersil has developeda series of Radiation Hardened MOSFETs specifically designed for commercial and military space applications. Enhanced Power MOSFET immunity toSingleEvent Effects (SEE), Single Event Gate Rupture (SEGR) in particular, is combined with 100K RADS of total dose hardness to provide devices which are ideally suited to harsh space environments. The dose rate and neutron tolerance necessary for military applications have not been sacrificed.
The Intersil portfolio of SEGR resistant radiation hardened MOSFETs includes N-Channel and P-Channel devices in a variety of voltage, current and on-resistance ratings. Numerous packaging options are also available.
This MOSFET is an enhancement-mode silicon-gate power field-effect transistor of the vertical DMOS (VDMOS) structure. It is specially designed and processed to be radiation tolerant. The MOSFET is well suited for applications exposed to radiation environments such as switching regulation, switching converters, motor drives, relay drivers and drivers for high-power bipolar switching transistors requiring high speed and low gate drive power. This type can be operated directly from integrated circuits.
File Number 4480.2
Features
• 9A, 100V, r
• Total Dose
- Meets Pre-RAD Specifications to 100K RAD (Si)
• Single Event
- Safe Operating Area Curve for Single Event Effects
- SEE Immunity for LET of 36MeV/mg/cm V
up to 80% of Rated Breakdown and
DS
V
of 10V Off-Bias
GS
• Dose Rate
- Typically Survives 3E9 RAD (Si)/s at 80% BV
- Typically Survives 2E12 if Current Limited to I
• Photo Current
- 1.5nA Per-RAD(Si)/s Typically
• Neutron
- Maintain Pre-RAD Specifications for 3E13 Neutrons/cm
- Usable to 3E14 Neutrons/cm
DS(ON)
= 0.180
2
2
with
2
Symbol
D
DSS
DM
Reliability screening is available as either commercial, TXV equivalent of MIL-S-19500, or Space equivalent of MIL-S-19500. Contact Intersil for any desired deviations from the data sheet.
Ordering Information
RAD LEVEL SCREENING LEVEL PART NUMBER/BRAND
10K Commercial FSL13A0D1 10K TXV FSL13A0D3 100K Commercial FSL13A0R1 100K TXV FSL13A0R3 100K Space FSL13A0R4
Formerly available as type TA17696.
Package
G
TO-205AF
S
G
S
D
4-1
CAUTION: These devices are sensitive to electrostatic discharge; follow proper IC Handling Procedures.
1-888-INTERSIL or 321-724-7143 | Copyright © Intersil Corporation 2000
FSL13A0D, FSL13A0R
Absolute Maximum Ratings T
= 25oC, Unless Otherwise Specified
C
FSL13A0D, FSL13A0R UNITS
Drain to Source Voltage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V
Drain to Gate Voltage (RGS = 20k) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V
DS
DGR
100 V 100 V
Continuous Drain Current
TC = 25oC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .I
TC = 100oC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .I
Pulsed Drain Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I
Gate to Source Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V
D D
DM
GS
9A 6A
27 A
±20 V
Maximum Power Dissipation
TC = 25oC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P
TC = 100oC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P
T T
25 W 10 W
Linear Derating Factor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.20 W/oC
Single Pulsed Avalanche Current, L = 100µH, (See Test Figure) . . . . . . . . . . . . . . . . . . . . . . . . . .I
AS
Continuous Source Current (Body Diode) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .I
Pulsed Source Current (Body Diode). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I
Operating and Storage Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . TJ, T
SM
STG
Lead Temperature (During Soldering) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .T
S
L
27 A
9A
27 A
-55 to 150 300
o
C
o
C
(Distance >0.063in (1.6mm) from Case, 10s Max)
CAUTION: Stresses above those listed in “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress only rating and operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied.
Electrical Specifications T
= 25oC, Unless Otherwise Specified
C
PARAMETER SYMBOL TEST CONDITIONS MIN TYP MAX UNITS
Drain to Source Breakdown Voltage BV Gate Threshold Voltage V
DSSID
GS(TH)VGS
= 1mA, VGS = 0V 100 - - V
= VDS,
ID = 1mA
TC = -55oC - - 5.0 V TC = 25oC 1.5 - 4.0 V TC = 125oC 0.5 - - V
Zero Gate Voltage Drain Current I
Gate to Source Leakage Current I
DSS
GSS
VDS = 80V, VGS = 0V
TC = 25oC--25µA TC = 125oC - - 250 µA
VGS = ±20V TC = 25oC - - 100 nA
TC = 125oC - - 200 nA Drain to Source On-State Voltage V Drain to Source On Resistance r
Turn-On Delay Time t
DS(ON)VGS
DS(ON)12ID
d(ON)
Rise Time t Turn-Off Delay Time t
d(OFF)
Fall Time t Total Gate Charge Q
g(TOT)VGS
Gate Charge at 12V Q Threshold Gate Charge Q Gate Charge Source Q Gate Charge Drain Q Plateau Voltage V
(PLATEAU)ID
Input Capacitance C Output Capacitance C Reverse Transfer Capacitance C Thermal Resistance Junction to Case R Thermal Resistance Junction to Ambient R
r
f
g(12)
g(TH)
gs
gd
ISS OSS RSS
JC
θ
JA
θ
= 12V, ID = 9A - - 1.70 V
= 6A,
VGS = 12V VDD = 50V, ID = 9A,
RL = 5.56, VGS = 12V, RGS = 7.5
TC = 25oC - 0.130 0.180 TC = 125oC - - 0.290
- - 20 ns
- - 80 ns
- - 45 ns
- - 30 ns
= 0V to 20V VDD = 50V,
VGS = 0V to 12V - 35 41 nC
ID = 9A
- - 60 nC
VGS = 0V to 2V - - 1.9 nC
- 6.7 8.2 nC
-1922nC
= 9A, VDS = 15V - 8 - V
VDS = 25V, VGS = 0V, f = 1MHz - 760 - pF
- 310 - pF
- 110 - pF
- - 5.0
- - 175
o o
C/W C/W
4-2
Source to Drain Diode Specifications
PARAMETER SYMBOL TEST CONDITIONS MIN TYP MAX UNITS
Forward Voltage V Reverse Recovery Time t
SD
rr
FSL13A0D, FSL13A0R
ISD = 9A 0.6 - 1.8 V ISD = 9A, dISD/dt = 100A/µs - - 260 ns
Electrical Specifications up to 100K RAD T
= 25oC, Unless Otherwise Specified
C
PARAMETER SYMBOL TEST CONDITIONS MIN MAX UNITS
Drain to Source Breakdown Volts (Note 3) BV Gate to Source Threshold Volts (Note 3) V Gate to Body Leakage (Notes 2, 3) I Zero Gate Leakage (Note 3) I Drain to Source On-State Volts (Notes 1, 3) V Drain to Source On Resistance (Notes 1, 3) r
DS(ON)12VGS
DSS
GS(TH)
GSS DSS
DS(ON)VGS
VGS = 0, ID = 1mA 100 - V VGS = VDS, ID = 1mA 1.5 4.0 V VGS = ±20V, VDS = 0V - 100 nA VGS = 0, VDS = 80V - 25 µA
= 12V, ID = 9A - 1.70 V = 12V, ID = 6A - 0.180
NOTES:
1. Pulse test, 300µs Max.
2. Absolute value.
3. Insitu Gamma bias must be sampled for both VGS = 12V, VDS = 0V and VGS = 0V, VDS = 80% BV
DSS
.
Single Event Effects (SEB, SEGR) (Note 4)
ENVIRONMENT (NOTE 5)
TEST SYMBOL
ION
SPECIES
TYPICAL LET
(MeV/mg/cm)
TYPICAL
RANGE (µ)
Single Event Effects Safe Operating Area SEESOA Ni 26 43 -20 100
Br 37 36 -10 100 Br 37 36 -15 80 Br 37 36 -20 50
NOTES:
4. Testing conducted at Brookhaven National Labs; sponsored by Naval Surface Warfare Center (NSWC), Crane, IN.
5. Fluence = 1E5 ions/cm2 (typical), T = 25oC.
6. Does not exhibit Single Event Burnout (SEB) or Single Event Gate Rupture (SEGR).
APPLIED
VGS BIAS
(V)
(NOTE 6)
MAXIMUM
VDSBIAS (V)
Typical Performance Curves Unless Otherwise Specified
2
GS
(V)
, RANGE = 43µ
LIMITING INDUCTANCE (HENRY)
1E-3
1E-4
1E-5
1E-6
1E-7
30
DRAIN SUPPLY (V)
GAMMA DOT CURRENT TO I
ILM = 10A 30A
100A
300A
30010010
AS
LET = 26MeV/mg/cm LET = 37MeV/mg/cm2, RANGE = 36µ
V
(V)
DS
V
120
100
80
60
40
20
FLUENCE = 1E5 IONS/cm2 (TYPICAL)
TEMP = 25oC
0
0 -10 -15 -20 -25-5
FIGURE 1. SINGLE EVENT EFFECTS SAFE OPERATING AREA FIGURE 2. DRAIN INDUCTANCE REQUIRED TO LIMIT
4-3
1000
Loading...
+ 5 hidden pages