Intersil Corporation FSGS230R Datasheet

TM
FSGS230R
Data Sheet June 2000
Radiation Hardened, SEGR Resistant N-Channel Power MOSFET
TM
developed for high performance applications in a commercial or
military space environment. Star*Power MOSFETs offer the system designer both extremely low r development of low loss Power Subsystems. Star*Power Gold FETs combine this electrical capability with total dose radiation hardness up to 100K RADs while maintaining the guaranteed performance for SEE (Single Event Effects) which the Intersil FS families have always featured.
The Intersil family of Star*Power FETs includes a series of devices in various voltage, current and package styles. The portfolio consists of Star*Power and Star*Power Gold products. Star*Power FETs are optimized for total dose and r
while exhibiting SEE capability at full rated voltage
DS(ON)
up to an LET of 37. Star*Power Gold FETs have been optimized for SEE and Gate Charge combining SEE performance to 80% of the rated voltage for an LET of 82 with extremely low gate charge characteristics.
This MOSFET is an enhancement-mode silicon-gate power field effect transistor of the vertical DMOS (VDMOS) structure. It is specifically designed and processed to be radiation tolerant. The MOSFET is well suited for applications exposed to radiation environments such as switching regulation, switching converters, power distribution, motor drives and relay drivers as well as other power control and conditioning applications. As with conventional MOSFETs these Radiation Hardened MOSFETs offer ease of voltage control, fast switching speeds and ability to parallel switching devices.
Reliability screening is available as either TXV or Space equivalent of MIL-S-19500.
and Gate Charge allowing the
DS(ON)
File Number 4867
Features
• 14A, 200V, r
• UIS Rated
• Total Dose
- Meets Pre-RAD Specifications to 100K RAD (Si)
• Single Event
- Safe Operating Area Curve for Single Event Effects
- SEE Immunity for LET of 82MeV/mg/cm V
up to 80% of Rated Breakdown and
DS
V
of 5V Off-Bias
GS
• Dose Rate
- Typically Survives 3E9 RAD (Si)/s at 80% BV
- Typically Survives 2E12 if Current Limited to I
• Photo Current
- 3.0nA Per-RAD (Si)/s Typically
• Neutron
- Maintain Pre-RAD Specifications for 1E13 Neutrons/cm
- Usable to 1E14 Neutrons/cm
DS(ON)
= 0.155
2
2
with
2
Symbol
D
G
S
Packaging
TO-257AA
S
D
G
DSS
AS
Formerly available as type TA45230W.
Ordering Information
RAD LEVEL SCREENING LEVEL PART NUMBER/BRAND
10K Engineering Samples FSGS230D1 100K TXV FSGS230R3 100K Space FSGS230R4
4-1
1-888-INTERSIL or 321-724-7143 | Intersil and Design is a trademark of Intersil Corporation. | Copyright © Intersil Corporation 2000
CAUTION: Beryllia Warning per MIL-S-19500
refer to package specifications.
CAUTION: These devices are sensitive to electrostatic discharge; follow proper ESD Handling Procedures.
FSGS230R
Absolute Maximum Ratings T
= 25oC, Unless Otherwise Specified
C
FSGS230R UNITS
Drain to Source Voltage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V
Drain to Gate Voltage (RGS = 20k) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V
DS
DGR
200 V 200 V
Continuous Drain Current
TC = 25oC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .I
TC = 100oC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .I
Pulsed Drain Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I
Gate to Source Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V
D D
DM
GS
14 A
9A
40 A
±30 V
Maximum Power Dissipation
TC = 25oC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P
TC = 100oC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P
T T
56 W 22 W
Linear Derating Factor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.45 W/oC
Single Pulsed Avalanche Current, L = 100µH (See Test Figure). . . . . . . . . . . . . . . . . . . . .I
Continuous Source Current (Body Diode) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .I
Pulsed Source Current (Body Diode). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I
Operating and Storage Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . TJ, T
STG
Lead Temperature (During Soldering) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . T
AS
S
SM
L
36 A 14 A 40 A
-55 to 150 300
o
C
o
C
(Distance >0.063in (1.6mm) from Case, 10s Max)
Weight (Typical) 4.4 (Typical) g
CAUTION: Stresses above those listed in “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress only rating and operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied.
Electrical Specifications T
= 25oC, Unless Otherwise Specified
C
PARAMETER SYMBOL TEST CONDITIONS MIN TYP MAX UNITS
Drain to Source Breakdown Voltage BV Gate Threshold Voltage V
DSSID
GS(TH)VGS
= 1mA, VGS = 0V 200 - - V
= VDS,
ID = 1mA
TC = -55oC - - 5.5 V TC = 25oC 2.0 - 4.5 V TC = 125oC 1.0 - - V
Zero Gate Voltage Drain Current I
Gate to Source Leakage Current I
DSS
GSS
VDS = 160V, VGS = 0V
TC = 25oC--25µA TC = 125oC - - 250 µA
VGS = ±30V TC = 25oC - - 100 nA
TC = 125oC - - 200 nA Drain to Source On-State Voltage V Drain to Source On Resistance r
Turn-On Delay Time t
DS(ON)VGS
DS(ON)12ID
d(ON)
Rise Time t Turn-Off Delay Time t
d(OFF)
Fall Time t Total Gate Charge Q Gate Charge Source Q Gate Charge Drain Q Gate Charge at 20V Q Threshold Gate Charge Q Plateau Voltage V
(PLATEAU)ID
Input Capacitance C Output Capacitance C Reverse Transfer Capacitance C Thermal Resistance Junction to Case R
r
f
g(12)
gs
gd
g(20)
g(TH)
ISS OSS RSS
JC
θ
= 12V, ID = 14A - - 2.31 V
= 9A,
VGS = 12V VDD = 100V, ID = 14A,
RL = 7.1, VGS = 12V, RGS = 7.5
TC = 25oC - 0.125 0.155 TC = 125oC - - 0.310
- - 20 ns
- - 40 ns
- - 35 ns
- - 15 ns
VGS = 0V to 12V VDD = 100V,
ID = 14A
-2628nC
-1012nC
- 8 10 nC VGS = 0V to 20V - 40 - nC VGS = 0V to 2V - 3 - nC
= 14A, VDS = 15V - 7 - V
VDS = 25V, VGS = 0V, f = 1MHz
- 1300 - pF
- 230 - pF
-8-pF
- - 2.2
o
C/W
4-2
Source to Drain Diode Specifications
PARAMETER SYMBOL TEST CONDITIONS MIN TYP MAX UNITS
Forward Voltage V Reverse Recovery Time t Reverse Recovery Charge Q
SD
rr
RR
FSGS230R
ISD = 14A - - 1.2 V ISD = 14A, dISD/dt = 100A/µs - - 220 ns
- 1.5 - µC
Electrical Specifications up to 100K RAD T
= 25oC, Unless Otherwise Specified
C
PARAMETER SYMBOL TEST CONDITIONS MIN MAX UNITS
Drain to Source Breakdown Volts (Note 3) BV Gate to Source Threshold Volts (Note 3) V Gate to Body Leakage (Notes 2, 3) I Zero Gate Leakage (Note 3) I Drain to Source On-State Volts (Notes 1, 3) V Drain to Source On Resistance (Notes 1, 3) r
DS(ON)12VGS
DSS
GS(TH)VGS
GSS DSS
DS(ON)VGS
VGS = 0, ID = 1mA 200 - V
= VDS, ID = 1mA 2.0 4.5 V VGS = ±30V, VDS = 0V - 100 nA VGS = 0, VDS = 160V - 25 µA
= 12V, ID = 14A - 2.31 V
= 12V, ID = 9A - 0.155
NOTES:
1. Pulse test, 300µs Max.
2. Absolute value.
3. Insitu Gamma bias must be sampled for both VGS = 12V, VDS = 0V and VGS = 0V, VDS = 80% BV
DSS
.
Single Event Effects (SEB, SEGR) Note 4
ENVIRONMENT (NOTE 5)
TEST SYMBOL
ION
SPECIES
TYPICAL LET
(MeV/mg/cm)
TYPICAL
RANGE (µ)
Single Event Effects Safe Operating Area SEESOA Br 37 36 -20 200
I 60 32 -10 200 Au 82 28 -5 160 Au 82 28 -10 120
NOTES:
4. Testing conducted at Brookhaven National Labs.
5. Fluence = 1E5 ions/cm2 (Typical), T = 25oC.
6. Does not exhibit Single Event Burnout (SEB) or Single Event Gate Rupture (SEGR).
APPLIED
VGS BIAS
(V)
(NOTE 6)
MAXIMUM
VDSBIAS (V)
Performance Curves Unless Otherwise Specified
GS
2
2
-15
(V)
, RANGE = 36µ
, RANGE = 28µ
-20 -25
(V)
DS
V
240
200
160
120
80
40
0
LET = 82 GOLD
LET = 37 BROMINE
LET = 60 IODINE
V
(V)
GS
-300 -5 -10 -15 -20 -25
-35 -40
LET = 37MeV/mg/cm LET = 60MeV/mg/cm2, RANGE = 32µ LET = 82MeV/mg/cm
FLUENCE = 1E5 IONS/cm2 (TYPICAL)
200
160
(V)
120
DS
V
80
40
TEMP = 25oC
0
0 -10
-5 V
FIGURE 1. SINGLE EVENT EFFECTS SAFE OPERATING AREA FIGURE 2. TYPICAL SEE SIGNATURE CURVE
4-3