Control panel for automatic removal and milk meter
MODEL
ACR Smart MMV
YEAR OF MANUFACTURE
2017
InterPuls is a registered trade mark of InterPuls SpA.
The information contained in this document is not binding and can be modified without notice. References in
this document to manufacturer trademarks are for identification only. Certain company and product names
used throughout the document are trademarks of their respective owners.
THIS MANUAL IS THE PROPERTY OF - InterPuls S.p.A.- ANY COPYING, EVEN PARTIAL, IS STRICTLY PROHIBITED
Sensitivity (only with HFS) ........................................................................................................... 29 6.2
Power off ...................................................................................................................................... 29 6.3
Configurations (only with HFS) .................................................................................................... 30 6.4
THIS MANUAL IS THE PROPERTY OF - InterPuls S.p.A.- ANY COPYING, EVEN PARTIAL, IS STRICTLY PROHIBITED
MI - 4
ACR Smart MMV - Instruction Manual, Operation and
Maintenance original instructions
5760006_02.17_EN
1 GENERAL INFORMATION
General information and safety warnings 1.1
1.1.1 Important warnings
To safeguard the operator and prevent any damage to the equipment, before carrying out any kind of
operation it is important to have read and fully understood the instruction manual.
1.1.2 Symbol used in this manual
The following symbols are used in this manual to highlight indications and warnings which are of particular
importance:
WARNING
This symbol indicates health and safety regulations designed to protect operators and/or any
exposed persons.
CAUTION
This symbol indicates that there is a risk of causing damage to the equipment and/or its
components.
NOTE
This symbol is used to highlight useful information.
1.1.3 Rules and regulations for the user
WARNING
Any failure to observe the warnings provided in this manual may lead to equipment
malfunctions or damage to the system.
1.1.4 Limitation of liability
InterPuls S.p.A. declines all liability for damage to persons, animals and/or things caused by incorrect use of
the equipment.
Prior using the product 1.2
1.2.1 Requirements and rules for personnel and Safety Rules
WARNING
Before using the device, the operator must carefully read the manual.
The person using the device must be of legal age and be trained and physically and mentally
fit. He or she must also have been provided with adequate information on how to operate the
device.
During the assembly and activation of the device, follow the instructions in the manual and
rules and regulations applying to health and safety at the workplace.
As the Portable ACR-SMART is an operator hand-held device, the operator must wear nonslip safety shoes during use to prevent damage from accidental falls of the device
THIS MANUAL IS THE PROPERTY OF - InterPuls S.p.A.- ANY COPYING, EVEN PARTIAL, IS STRICTLY PROHIBITED
MI - 5
5760006_02.17_EN
ACR Smart MMV - Instruction Manual, Operation and
Maintenance original instructions
Disposal 1.3
1.3.1 General regulation
The appliances must be disposed of only and exclusively by specially authorized waste disposal companies
in accordance with all relative legislation and prescriptions.
The packaging must be consigned to the relative authorized companies to be recycled.
Fire prevention 1.4
1.4.1 Fire prevention
NOTE
The machine is not equipped with fire extinguishers.
The operator must make sure that the place in which the appliance is installed is equipped
with an adequate number of suitable fire extinguishers. The extinguishers must be positioned
where they are clearly visible and protected from damage and improper use.
1.4.2 Safety regulations
WARNING
It is strictly prohibited to extinguish fires involving electrical equipment with water!
1.4.3 Characteristic of extinguishers
Use powder, foam or halogen extinguishers which must be positioned next to the device.
Operating personnel must receive adequate instruction on how to use the extinguishers.
THIS MANUAL IS THE PROPERTY OF - InterPuls S.p.A.- ANY COPYING, EVEN PARTIAL, IS STRICTLY PROHIBITED
MI - 6
ACR Smart MMV - Instruction Manual, Operation and
Maintenance original instructions
5760006_02.17_EN
General technical characteristics
Dimensions
130x180x38 mm (5.12x7.08x1.5 in)
Weight
0.45 kg (0.99 lb)
Power supply
24 VDC
Power consumption (only panel)
max 60 mA
Power consumption (entire system)
Panel – Milk Meter – LE30 – CV – ½ LE30
- alarm
max 600mA
Protection rating (cables installed properly)
IP 67
Operating vacuum
between 20 and 60kPa (between 5.9 and 17.71 “Hg)
Operating temperature (environment)
+3ºC ÷ +40ºC (+37.4°F ÷ +104°F)
Transport/storage temperature
-20ºC ÷ +50ºC (-4°F ÷ +122°F)
2 DESCRIPTION OF THE MACHINE
General characteristics 2.1
The ACRSmart MMV is a panel designed to control all the functions of milking, washing and detachment of
the unit.
Furthermore, with InterPuls Milk Meter, ACRSmart MMV is able to measure the milk production with errors
below 2%.
The panel can work with Milk Meter InterPuls and also with flow sensor HFS InterPuls.
The ACRSmart MMV is able to control the milking frequency and the pulsation ratio in a wide range of values
in order to meet the needs of all system (both in high line and low line) and of all type of animals (cattle –
sheep – goat).
The ACRSmart MMV is able to perform a stimulation that can be forced, automatic (dependent on the flow of
milk) or manual (activated directly by the milker at any time).
The panel is compatible with swing-over systems in which the unit is detached by moving the arm. In fact,
with the ACRSmart MMV you can control the pneumatic cylinder responsible for moving the unit from the
right hand row to the left hand row and vice versa.
It is suitable for milk transport systems thanks to the alarm indicating the end of the milking process and the
possibility to restart the panel from the last active stage.
The ACRSmart MMV can be connected to remote start-up devices (AutoStart) and remote stop devices
(Quick Lift Line).
Technical features
2.2
THIS MANUAL IS THE PROPERTY OF - InterPuls S.p.A.- ANY COPYING, EVEN PARTIAL, IS STRICTLY PROHIBITED
MI - 7
5760006_02.17_EN
ACR Smart MMV - Instruction Manual, Operation and
Maintenance original instructions
Blue
Brown
Black
Blue
29
30
31
32
Pink
Brown
Brown
Black
25
26
27
28
Grey
White
Yellow
Green
21
22
23
24
Blue
Black
Red
Blue
17
18
19
20
Black
Blue
Black
Brown
13
14
15
16
Black
Shield
Blue
Black
9
10
11
12
Grey
Pink
Blue
Red
5 6 7
8
Brown
White
Green
Yellow
1 2 3
4
IUP
MMV
IUP
FILTERED AIR LINE
VACUUM LINE
MILK LINE
ACR Smart
MMV
+24VDC
-24VDC
CV20
LE30
CV30
VAC/ATM
MMV
DVC AS
END OF
MILKING
LAMP
QUICK-LIFT
BUTTON
TO THE
NEXT PANEL
TO THE
NEXT PANEL
ATM
VAC
ADDITIONAL
VACUUM LINE
(minØ40)
Wiring diagrams 2.3
2.3.1 Connection diagram with MMV sensor
THIS MANUAL IS THE PROPERTY OF - InterPuls S.p.A.- ANY COPYING, EVEN PARTIAL, IS STRICTLY PROHIBITED
MI - 8
ACR Smart MMV - Instruction Manual, Operation and
Maintenance original instructions
5760006_02.17_EN
N°
terminal
PCB
Wiring
N°
wire
Color
Description
Type of
wiring
Wire color
(device side)
N° wire
(device
side)
1
8 poles cable
19
Red
PCB power
supply
24 VDC (+)
- - 2
8 poles cable
20
Blue
24 VDC (-)
-
-
3
End of milking
lamp
11
Blue
Lamp power
supply
24 VDC (+)
- - 4
12
Black
24 VDC (-)
- - 5
DVC AS
13
Black
Autostart
- - -
6
14
Blue - - - 7
Quick lift line
-
Clean contact
- - -
-
8
-
9
8 poles cable
21
Grey
LE30
Rear
Brown
27
10
8 poles cable
22
White
Common
Black
28
11
8 poles cable
23
Yellow
Front
Blue
29
12
8 poles cable
24
Green
CV
Left channel
(S/O)
Brown
30
13
CV (2x2)
15
Black (blue for the
second milking
point)
Detachment
(DVC)
Common
-
-
14
16
Brown (grey for the
second milking
point)
to the DVC
-
-
15
16
17
MMV cable
8
Red
Temperature
probe
Ground
Black 9 18
MMV cable
7
Blue
IN
Black 9 19
8 poles cable
25
Pink
CV
Common
Black
31
20
8 poles cable
26
Brown
Right channel
(dump valve)
Blue
32
21
MMV cable
4 e 10
White + shield
MMV power
supply
5 VDC (-)
White
4
22
MMV cable
22
Yellow
Level
LIV 2
Yellow
3
23
MMV cable
23
Green
LIV 1
Green
2
24
MMV cable
24
Brown
MMV power
supply
5 VDC (+)
Brown
1
THIS MANUAL IS THE PROPERTY OF - InterPuls S.p.A.- ANY COPYING, EVEN PARTIAL, IS STRICTLY PROHIBITED
MI - 9
5760006_02.17_EN
ACR Smart MMV - Instruction Manual, Operation and
Maintenance original instructions
1
Rosso
4 Bianco
7 Rosa
10
Nero
13
Marrone
16
Blu
2
Blu 5
Giallo 8
Marrone
11
Nero
14
Nero
17
Nero
3
Grigio
6 verde 9
Blu 12
Blu 15
Blu 18
Marrone
IUP
CV20
VACUUM LINE
LE30
+24VDC
-24VDC
FILTERED AIR LINE
MILK LINE
HFS EVO
ACRSmart MMV
QUICK-LIFT
BUTTON
TO THE NEXT
PANEL
DVC AS
END OF
MILKING
LAMP
2.3.2 Connection diagram with HFS Flow sensor
THIS MANUAL IS THE PROPERTY OF - InterPuls S.p.A.- ANY COPYING, EVEN PARTIAL, IS STRICTLY PROHIBITED
MI - 10
ACR Smart MMV - Instruction Manual, Operation and
Maintenance original instructions
5760006_02.17_EN
N°
terminal
PCB
Wiring
N°
wire
Color
Description
Type of
wiring
Wire color
(device side)
N° wire
(device
side)
1
8 poles cable
1
Red
PCB power
supply
24 VDC (+)
-
-
2
8 poles cable
2
Blue
24 VDC (-)
-
-
3
end of milking
lamp
9
Blue
Lamp power
supply
24 VDC (+)
-
-
4
10
Black
24 VDC (-)
- - 5
DVC AS
11
Black
Autostart
- - -
6
12
Blue - -
-
7
Quick lift line
Clean contact
- - -
-
8
9
8 poles cable
3
Grey
LE30
Rear
Brown
13
10
8 poles cable
4
White
Common
Black
14
11
8 poles cable
5
Yellow
Front
Blue
15
12
8 poles cable
6
Green
CV30
to S/O
Blue
16
13
8 poles cable
7
Pink
Common
Black
17
14
8 poles cable
8
Brown
to the DVC
Brown
18
15
HFS
Clean contact
Milk flow - -
-
16 17 18
19
20
21 22
23
24
2.3.3 Choice of CV
It’s possible to set the ACRSmart MMV panel in order to use solenoid valves normally open or normally
closed by setting the following parameters:
- E.S-O : shut-off solenoid valve
- E.DVC : cylinder solenoid valve
- E.dMP. : dump valve solenoid valve
Set these parameters on:
- N.OP. (normally open) if the utility is connected to a VAC channel of the CV (eg. for CV20 or left
channel of CV30 inv)
- N.CL. (normally closed) if the utility is connected to a ATM channel of the CV (eg. for CV30 or
right channel of CV30 inv)
The default settings require the utilization of a CV20 for cylinder (E.DVC = N.OP.) and a CV30 inv for
shut-off and for dump valve (E.S-O = N.OP. , E.dMP. = N.CL.)
THIS MANUAL IS THE PROPERTY OF - InterPuls S.p.A.- ANY COPYING, EVEN PARTIAL, IS STRICTLY PROHIBITED
MI - 11
5760006_02.17_EN
ACR Smart MMV - Instruction Manual, Operation and
Maintenance original instructions
A
F
B
D
C
E
3 DESCRIPTION OF THE DEVICE
A) Display
B) LEDs (green and red)
C) STOP key
D) Milking process START button with automatic detachment, continuous pressure for 3’’ stimulation
start
E) Key to show milk production or milking time
F) Combination of key for accessing the washing or programming mode
THIS MANUAL IS THE PROPERTY OF - InterPuls S.p.A.- ANY COPYING, EVEN PARTIAL, IS STRICTLY PROHIBITED
MI - 12
ACR Smart MMV - Instruction Manual, Operation and
Maintenance original instructions
5760006_02.17_EN
Display
Indication
Meaning
Code St.on.
Start of stimulation
Code St.oF.
End of stimulation
Code diS
Washing (only with HFS sensor)
Code E + temperature
EMPTY phase during washing and
temperature indication (only with MMV
sensor)
Code F + temperature
FILL phase during washing and
temperature indication (only with MMV
sensor)
xx.xx with point on time symbol
Milking time
xx.x with point on quantity symbol
Milk production (only with MMV sensor)
Right point blinking
Continuous milk flow
Display during operation 3.1
THIS MANUAL IS THE PROPERTY OF - InterPuls S.p.A.- ANY COPYING, EVEN PARTIAL, IS STRICTLY PROHIBITED
MI - 13
5760006_02.17_EN
ACR Smart MMV - Instruction Manual, Operation and
Maintenance original instructions
Key
Function
briefly
Start automatic milking (reset of milking time and milk measurement)
briefly
Removal or release of the milking unit
+ briefly
Start washing
+ x 10”
Access programming mode
briefly
Change display visualization from milking time to milk quantity and vice
versa
hold
Show the whole milking production (from last reset)
hold +
Reset the whole milking production
hold +
Reattached the same animal (keep the last milking time and the last milk
production)
QUICK-LIFT operation
Removal or release of the milking unit
AUTO-START operation
Start automatic milking via remote control (cylinder with auto-start or
remote button)
4 DESCRIPTION OF THE FUNCTIONS
Upon start-up the panel display indicates the software version installed. Depending on the configured
settings (parameter In.P.), then the panel starts during:
- washing
- detachment (default)
- last active phase
Detachment phase (stand-by) 4.1
Depending on the settings (parameter dEF.P.), the panel shows the milking production (point on
symbol) or the milking time (point on symbol) of last animal; at the start, the display shows time and
production equal to zero.
Green led of detachment is on to signal that the cluster is in removal position. The S/O valve stays
closed, while the unit position may switch from release to removal or vice versa by pressing STOP button
or via cluster up/down line; when the unit is released, the green led turns off.
THIS MANUAL IS THE PROPERTY OF - InterPuls S.p.A.- ANY COPYING, EVEN PARTIAL, IS STRICTLY PROHIBITED
MI - 14
ACR Smart MMV - Instruction Manual, Operation and
Maintenance original instructions
5760006_02.17_EN
Washing 4.2
The wash phase can be operated:
Manually when the system is in detachment position by pressing together + briefly
Automatically if pre-set as the start-up phase on the programming menu (parameters In.P. set on
diS.)
By pressing STOP button during washing, the phase stops and the panel returns to stand-by mode,
the unit is not removed from washing plate.
By pressing again the STOP button the cluster is removed.
CAUTION
At the end of washing phase it’s recommended to power off the ACRSmart MMV panels to
avoid that the coils of control valves stay powered for long time and being damaged. Upon
start-up, the panel may restart in washing phase or detachment phase according to the
parameter In.PH.
4.2.1 Washing with HFS
Washing visualization with HFS
The display features the code diS. And the green washing led starts blinking. The unit is released and
the count relating to the shut-off closure delay starts (parameter c.S.d.). When it is elapsed, the shut-off
valve is opened and the washing stage starts.
It’s possible to change the frequency during washing (parameter diS.F.).
Press the STOP button or the cluster up/down command to stop washing cycle and retract the unit.
THIS MANUAL IS THE PROPERTY OF - InterPuls S.p.A.- ANY COPYING, EVEN PARTIAL, IS STRICTLY PROHIBITED
MI - 15
5760006_02.17_EN
ACR Smart MMV - Instruction Manual, Operation and
Maintenance original instructions
4.2.2 Washing with Milk Meter
The panel alternates FILL phase and EMPTY phase; between the two phases, the dump-valve is activated
to allow the emptying of the sensor.
During the FILL phase, the dump-valve stays closed to permit the complete filling of the milk meter to wash it
in each of his part. The FILL phase lasts for the Fill time (parameter FILL).
The display features code “F” and the temperature of the water.
FILL phase with water at 63°C (145.4°F)
During the EMPTY phase, the dump-valve is closed until the floater reaches the second level. Then the shutoff stays open as setting in the parameter Dump time (parameter dMP.t.) to discharge the water. After that
the milk meter starts again to fill and to discharge until the Empty time elapsed (parameter EMPt).
The display features code “E” and the temperature of the water.
EMPTY phase with water at 51°C (123.8°F)
The washing parameters have to be modified to allow the complete filling and emptying of the sensors.
Depending from the parlour configuration, you may need to set different values of FILL and EMPt
parameters to allow the correct washing of each sensor.
In the milking points far from the water entrance, if there isn’t enough water to completely filling of the sensor
(FILL PHASE), it’s necessary to increase fill time (parameter FILL); equally, to make available more water,
it’s also possible to increase empty time (parameter EMPt).
Milking 4.3
4.3.1 Milking with automatic cluster removal
To start the milking process with automatic detachment press the START button during detachment
phase or operate the Auto-start contact.
NOTE
The connectors 5-6 (clean contact) can be connected to a REMOTE BUTTON or an AUTOSTART cylinder to start a milking without using button.
When the milking with automatic detachment starts:
Cylinder releases the unit
After the Vacuum/pulsation delay (parameter PuL.d.), the pulsator is activates and the shut-off valve
is opened.
4.3.2 Milking with HFS
At the beginning of the milking, the display shows the milking time and the panel counts of Initial delay
(parameter In.d.).
When the milking presence signal constantly exceeds the value defined by the position of the jumpers, the
panel detects a presence of milk and the first dot on the right starts blinking.
If the presence of milk lasts more than Continuous flux time (parameter M.d.F.), the panel detects a real milk
flux.
THIS MANUAL IS THE PROPERTY OF - InterPuls S.p.A.- ANY COPYING, EVEN PARTIAL, IS STRICTLY PROHIBITED
MI - 16
ACR Smart MMV - Instruction Manual, Operation and
Maintenance original instructions
5760006_02.17_EN
The panel shows the milking time in MM.SS size; the central dot is on clock symbol .
At the end of Initial delay (parameter In.d.) when there’s no longer milk flux, the count of Final delay
(parameter Fin.d.) starts; the detachment operations start when this delay has elapsed.
Milking time (4minutes and 58 seconds) with milk flow
During all milking stages, press the START button to switch from automatic to manual milking and
vice versa.
Press STOP button (or activate the Cluster up/down button) to immediately stop the milking and
start the detachment operations.
4.3.3 Milking with MMV
At the beginning of the milking, the panel starts counting of Initial delay (parameter In.d.).
The display can show:
- Milk yield (if parameter dEF.P = MiLK) – point on symbol
Milk yield (14.8 Kg)
- Milking time (if parameter dEF.P = tiME) – point on symbol
Milking time (2 minutes and 17 seconds) with milk flow
It’s always possible to pass from milk yield to milking time visualization and vice versa by pressing
button.
During milking, the point in the right corner of the display shows if in that moment there’s milk in the sensor. If
the milk flow is higher than the parameter Detachment flow (parameter dEt.F.), the panel detects a
continuous flow.
At the end of Initial delay (parameter In.d.), when there is no longer any milk flow, the panel start counting
final delay (parameter Fin.d.). The detachment operations start when this delay has elapsed.
During all milking stages, press the key to switch from automatic milking to manual milking and vice
versa.
Press the key (or activate the quick-lift button) to immediately stop the milking operations and start
the detachment operations.
THIS MANUAL IS THE PROPERTY OF - InterPuls S.p.A.- ANY COPYING, EVEN PARTIAL, IS STRICTLY PROHIBITED
MI - 17
5760006_02.17_EN
ACR Smart MMV - Instruction Manual, Operation and
Maintenance original instructions
4.3.4 Manual milking
To start milking with manual unit removal, press the key after the system has been started in
automatic milking mode:
The red led of manual milking stays on
The panel stays in the manual milking mode as long as:
the button is pressed to switch to the automatic milking mode
or
the button is pressed to start the detachment operations
Press the key to switch from the manual milking mode to the automatic milking mode and vice versa,
at any time.
4.3.5 Maximum milking time
WARNING
You can envisage a maximum milking time, which can be set or disabled in the programming
menu (parameter M.M.t.)
If this limit is reached, the unit detachment operations start automatically and, in the event of
no flow during the milking process, the anomaly is signaled via an alarm (see chapter 4.7
Alarm)
Detachment operation 4.4
When the Initial delay (parameter In.d.) has elapsed, if the panel does not detect a continuous flow (HFS) or
a minimum flow (MMV) of milk, the final delay count starts (parameter Fin.d.) and the green led of
detachment starts flashing .
If the flow of milk is resumed, the delay is reset. The unit removal operations start when the final delay has
elapsed.
The removal procedure can also be started manually by pressing the key o by activating Quick-Lift
button.
When the detachment operation start:
the pulsator stops
the S/O Valve closes the vacuum passage
the detachment delay time count starts (parameter det.d.), in order to wait for a certain amount of air
to leak through the collection unit hole, lowering the vacuum level under the nipples before removing
the unit
when the delay has elapsed, the cylinder gently removes the unit and the green led stays fixed
on.
if the suction function has been activated (parameter SPt.L.), when the suction delay time has
elapsed (parameter SPt.d.) the residue milk in the collection unit and in the milk pipe is aspirated
through the flow meter.
THIS MANUAL IS THE PROPERTY OF - InterPuls S.p.A.- ANY COPYING, EVEN PARTIAL, IS STRICTLY PROHIBITED
MI - 18
ACR Smart MMV - Instruction Manual, Operation and
Maintenance original instructions
5760006_02.17_EN
if the automatic unit release function has been activated, when the automatic release delay has
elapsed (parameter A.r.d.) the unit is released automatically to start a new milking session.
At the end of detachment operation the green led of detachment stays fixed on and the display shows
the milking time or the milk yield (only with MMV). The pair of terminals 3-4 is powered at 24VDC; the pair of
terminals can be connected to a flashing light for indicating the end of milking.
Press the key to switch off the flashing light and the cylinder releases the milking unit (you can put it
on washing plates).
Press key to start a new milking session.
Press key to switch the display visualization from milking time to milk yield and vice versa (only with
MMV).
If you press and hold key, the display shows the total milk yield from the last reset (only with MMV).
If you press and hold key and then press also key, the total milk yield is reset.
Reattachment 4.5
At the end of detachment operation, if the farmer believes that the animal still has milk, it’s possible to make
a reattachment, that is a new milking but without milking time and milk yield reset (these data restart from
the values of the last detachment).
To make a reattachment, press and hold key and then press also key. The reattachment is like
a normal milking and at the end start the detachment operation.
THIS MANUAL IS THE PROPERTY OF - InterPuls S.p.A.- ANY COPYING, EVEN PARTIAL, IS STRICTLY PROHIBITED
MI - 19
5760006_02.17_EN
ACR Smart MMV - Instruction Manual, Operation and
Maintenance original instructions
Stimulation 4.6
At the beginning of stimulation, the display features the code St.on. for 3 seconds.
On the programming menu you can define the type of stimulation (parameter St.tY.) which may be:
Forced (Forc)
Automatic (Auto)
OFF (oFF) – can only be activated manually
FORCED STIMULATION
During programming you can set a forced stimulation cycle at the beginning of each milking process.
For a certain period of time (stimulation time, which can be set via parameter St.t.) the frequency
and pulsation ratio are gradually modified in order to reach the set values (stimulation frequency
St.F., stimulation ratio St.r.)
AUTOMATIC STIMULATION
Stimulation starts if the function is enabled and if during milking the sensor does not detect presence
of milk for a certain period of time (called neutral time, which can be set via parameter nEU.t.
Therefore the frequency and pulsation ratio vary gradually until reaching the values set for
stimulation (stimulation frequency St.F., stimulation ratio St.r.)
Stimulation stops when the flow meter starts detecting a presence of milk again or when the
stimulation time elapses (parameter St.t.)
MANUAL STIMULATION
Press and hold the key for 3” during the milking cycle (with any value set for parameter St.tY.) to start the manual stimulation process: the frequency and pulsation ratio vary gradually until
reaching the values set for stimulation (stimulation frequency St.F., stimulation ratio St.r.).
Stimulation stops when the stimulation time has elapsed (parameter St.t.).
A couple of second before the stop of stimulation, the display features the code St.oF. for 3 seconds, after
that the frequency and pulsation ratio gradually go back to the values set for milking. Then the display
features again the milking time or the milk yield
NOTE
By setting stimulation ratio (parameter St.r.) on value 0, upon start of the stimulation, the
liners stay completely closed and the pulsation stops until the end of stimulation time (St.t.).
THIS MANUAL IS THE PROPERTY OF - InterPuls S.p.A.- ANY COPYING, EVEN PARTIAL, IS STRICTLY PROHIBITED
MI - 20
ACR Smart MMV - Instruction Manual, Operation and
Maintenance original instructions
5760006_02.17_EN
L/min
Initial delay
Final
delay
Final
delay
Final
Delay
Detachment
operation
Time
Start of milking session
When the Pulsation delay
has elapsed, the pulsator is
activated
The Initial delay count
starts
When the initial delay has
elapsed, the sensor starts
monitoring the presence of
milk flow
If a milk flow is detected,
the milking process
continues normally
If a milk flow is not detected,
the final delay count starts
Is a milk flow is detected
before the final delay has
elapsed, the milking
process continues normally
If a milk flow is not detected
before the final delay has
elapsed, the detachment
operations start and the
operator is warned by the
warning LED . Now,
press the button
to delete the alarm.
As soon as there is no milk
flow, the final delay count
starts
As soon a milk flow is
detected again, the milking
process continues normally
If a milk flow is not detected,
the detachment operations
start
THIS MANUAL IS THE PROPERTY OF - InterPuls S.p.A.- ANY COPYING, EVEN PARTIAL, IS STRICTLY PROHIBITED
MI - 21
5760006_02.17_EN
ACR Smart MMV - Instruction Manual, Operation and
Maintenance original instructions
Alarm 4.7
If a continuous flow is not detected during the milking process, when the Initial delay has elapsed and during
the subsequent final delay time count, the red alarm LED starts flashing and the unit removal
procedures start automatically.
Press the to reset the alarm and switch to the detachment mode (stand-by), the alarm lamp and the
alarm LED stop flashing and detachment led stays fixed on.
Press the to start a new milking session.
Quick-Lift 4.8
The quick-lift button corresponds to pressing the key on the panel.
If terminals 7-8 on all the panels are connected to an external button, by pressing this key you can lift or
release all the units at the same time. This way, at the beginning of the milking process, you can release all
the units at the same time.
WARNING
Do not activate the quick-lift button during washing or during milking; milking units would be
all removed from animals or from washing dishes.
Swing-over (only with detachment made by pneumatic cylinder) 4.9
By activating the Swing-Over mode (type of detachment dEt.t = S.OVE. parameter) the ACRSmart MMV
panel can manage systems in which the unit is detached via a pneumatic piston that moves the Swing-Over
arm from one side to the other.
By connecting this piston to the CV output, normally dedicated to the DVC, and setting Type of System
parameter (det.t.) on value S.OVE., at the end of the milking process the panel will automatically move the
arm in order to start milking again on the other side.
Therefore, via the button or via the remote Quick-Lift button, you can move arms from one side of
the milking parlour to the other.
THIS MANUAL IS THE PROPERTY OF - InterPuls S.p.A.- ANY COPYING, EVEN PARTIAL, IS STRICTLY PROHIBITED
MI - 22
ACR Smart MMV - Instruction Manual, Operation and
Maintenance original instructions
5760006_02.17_EN
Ø 1 mm
(Ø 0.04 in)
Ø 3.5 mm
(Ø 0.14 in)
Rubber pipe
Rubber pipe
Calibration (with MMV) 4.10
The parameter CAL.M. is used to calibrate the MMV sensor for each ACRSmart MMV of the parlour. Each
installation requires different settings due to the different vacuum level, tube length, air input and milk
ascent/rising.
It’s recommended to calibrate the system once a year.
Use pure water without acid or salts. The calibration must be done on clean sensors.
Each parameter CAL.M. corresponds to ±1%.
WARNINGS
- We suggest calibrating the system after one week of system operation because the parts
must adapt to function properly. On average, the calibration parameter fluctuates by 2 points
after the parts have settled.
- We suggest calibrating the system at least once a year for best operation.
4.10.1 Equipment
A SUCTION SET composed by:
- Plastic pipe with a sucking hole of Ø 3.5mm
- Plastic pipe with an air inlet 1 mm
Connect the two parts with a piece of rubber hose and prepare a second tube to connect the set to the
sensor.
THIS MANUAL IS THE PROPERTY OF - InterPuls S.p.A.- ANY COPYING, EVEN PARTIAL, IS STRICTLY PROHIBITED
MI - 23
5760006_02.17_EN
ACR Smart MMV - Instruction Manual, Operation and
Maintenance original instructions
A narrow and high BUCKET of sufficient capacity (more than 10l – more than 0.35 ft3)
THIS MANUAL IS THE PROPERTY OF - InterPuls S.p.A.- ANY COPYING, EVEN PARTIAL, IS STRICTLY PROHIBITED
MI - 24
ACR Smart MMV - Instruction Manual, Operation and
Maintenance original instructions
5760006_02.17_EN
N° test
Milk yield
measured
Difference
Average
error
1
9.3
9.3 – 9.6 =
- 0.3 kg (-0.66 lb)
- 0.3 kg
(-0.66 lb)
2
9.2
9.2 – 9.6 =
- 0.4 kg (-0.88 lb)
3
9.4
9.4 – 9.6 =
- 0.2 kg (-0.44 lb)
4.10.2 Testing proceeding
1. Remove the cluster from the milk hose and connect the suction device with a rubber chunk
2. Fill the bucket with 10l (0.35 ft3) of water (=10Kg – 22.04 lb). The temperature of the water should be
approximately 25°C ±10°C (77°F ± 50°F) without salt or acid.
3. From stand-by mode, start a new automatic milking with button
4. Put the suction device in the bucket taking care that the 3.5mm (0.14 in) hole remains always under
the water level until the container is completely empty and the air inlet hole remains above the water
level.
5. Completely suck the 10l (0.35 ft3) of water, waiting the automatic detachment of the panel
6. At the end of detachment operation, the panel shows the milk yield (if the display features the milking
time, press key to show milk yield).
With a properly calibration, the display should show 9.6±0.1 kg (21.16±0.22 lb) (You may have slight variations in the specific weight depending on the animal milked and the type of alimentation)
7. Take note of the measured value
8. If the measurement is different from the reference value (9.6 kg - 21.16 lb) of ±0.1kg (0.22 lb), then
the calibration is correct and no further check is necessary.
9. If the different is more than ±0.1kg (0.22 lb) proceed with 2 further tests, taking note of the values
10. Calculate the average value between the errors of the 3 measurement
11. Now it’s necessary increase/decrease the parameter of calibration CAL.M. of 1 step for each 0.1kg (0.22 lb) of difference from 9.6 kg (21.16 lb).
E.G.
After 3 tests you have the following results
The panel underrates an average error of 0.3kg (0.66 lb) for each milking. So you have to increase the
parameter of calibration CAL.M. of 3 steps.
WARNINGS
If calibration is carried out during plant testing (or just after having carried out routine
maintenance on the MMV), without waiting for the week suggested to allow the parts to settle,
with 10 kg of water in the bucket the panel must measure 9.8±0.1 kg (21.6±0.22 lb) and not 9.6
kg (21.16 lb) as specified in the standard procedure.
THIS MANUAL IS THE PROPERTY OF - InterPuls S.p.A.- ANY COPYING, EVEN PARTIAL, IS STRICTLY PROHIBITED
MI - 25
5760006_02.17_EN
ACR Smart MMV - Instruction Manual, Operation and
Maintenance original instructions
5 PROGRAMMING MODE
Accessing the programming mode 5.1
To access the Programming menu, press the + keys for 10” while the system is in
detachment mode.
The display features the first parameter identified by its code and the LEDs start flashing alternately.
Modifying parameters 5.2
In the programming menu you can edit the values associated to the parameters in order to optimize the
milking, stimulation, detachment and washing operations.
The display features the code of the selected parameter.
Press the or keys to scroll the available parameters, each identified by its code.
Press the key to access the parameter and modify it. The current value of the selected parameter is
displayed.
Press the or keys to scroll the parameter values.
Press the key to confirm the value assigned to the parameter and go back to the previous menu. If the
parameter has been modified, the display flashes.
To exit the programming mode press and hold the + keys for 10”; the panel is then
automatically restarted and the version of the software currently installed in displayed.
THIS MANUAL IS THE PROPERTY OF - InterPuls S.p.A.- ANY COPYING, EVEN PARTIAL, IS STRICTLY PROHIBITED
MI - 26
ACR Smart MMV - Instruction Manual, Operation and
Maintenance original instructions
5760006_02.17_EN
Parameter name
Code
Description
Range
Unit of
measure
Default
TYPE OF SENSOR
SEnS
Definition of the type of sensor is used
(volumetric milk meter MMV or flux
sensor HFS)
MMV.2
MMV.1 (NOT
USED)
HFS
//
MMV.2
SHUT OFF
SOLENOID VALVE
E.S-O
Select the type of solenoid valve used for
shut-off, N.OP. - normally open (vac
channel) or N.CL. - normally closed (atm
channel)
N.OP – N.CL
//
N.OP.
CYLINDER
SOLENOID VALVE
E.DVC
Select the type of solenoid valve used for
DVC, N.OP. - normally open (vac channel)
or N.CL. - normally closed (atm channel)
N.OP – N.CL
//
N.OP.
DUMP VALVE
SOLENOID VALVE
E.dMP
Select the type of solenoid valve used for
dump valve, N.Op. - normally open (vac
channel) or N.Cl. - normally closed (atm
channel)
N.OP – N.CL
//
N.CL.
INITIAL DELAY
In.d
Time at the beginning of the milking
process in which milk presence is not
checked
0÷190
seconds
80
PULSATION
DELAY
PuL.d
Delay between the beginning of the
milking process and the pulsation starting
0÷9
seconds
0
FRONT
PULSATION
RATIO
Mi.r.F.
Pulsation ratio of the hindquarters during
the milking process
10:90÷90:10
Pulsation
ratio
60:40
REAR PULSATION
RATIO
Mi.r.r.
Pulsation ratio of the forequarters during
the milking process
10:90÷90:10
Pulsation
ratio
60:40
PULSATION
FREQUENCY
Mi.Fr.
Pulsation frequency during the milking
process
50÷180
LP
Ppm
60
FINAL DELAY
Fin.d
If the panel does not detect a continuous
flow of milk throughout the entire delay, it
starts the detachment operations
0÷30
seconds
9
CONTINUOS
FLOW TIME
M.d.F.
If the sensor detects the presence of milk
for a period equal to the continuous flow
time, then there is an actual flow of milk
0÷4.0
seconds
1.0
DETACHEMNT
FLOW
dEt.F.
If the MMV detects a milk flow lower than
the parameters, the final delay count
starts
0÷1000
gr/min
250 gr/min
MAX MILKING
TIME
M.M.t.
The detachment operations always start
when this time has elapsed
10 - 15 - 20
Minutes
20
DETACHMENT
TYPE
dEt.t
Definition of the type of system in which
the panel is used:
- CYL: Standard system
- S.OVE: Swing-Over
CYL – S.OVE
//
CY
DETACHEMENT
DELAY
dEt.d
At the end of the milking process, it is the
delay between the closure of the s/o valve
and the unit removal
0÷9
seconds
3
Programming parameter table 5.3
THIS MANUAL IS THE PROPERTY OF - InterPuls S.p.A.- ANY COPYING, EVEN PARTIAL, IS STRICTLY PROHIBITED
MI - 27
5760006_02.17_EN
ACR Smart MMV - Instruction Manual, Operation and
Maintenance original instructions
TYPE OF
STIMULATION
St.tY.
Selection of type of stimulation
- Forc: forced stimulation
- Auto: automatic stimulation
- oFF: stimulation that can only be
activated manually
See chapter 4.6 Stimulation
Forc - Auto -
oFF
//
Auto
STIMULATION
RATIO
St.r
Pulsation ratio during stimulation
0:100 ÷ 100:0
Pulsation
ratio
30:70
STIMULATION
FREQUENCY
St.Fr
Pulsation frequency during the stimulation
stage
30 ÷ 240
Ppm
120
STIMULATION
TIME
St.t
Duration of stimulation
10÷90
seconds
15
NEUTRAL TIME
nEU.t.
When this time has elapsed, if there has
not been a continuous flow of milk,
automatic stimulation starts if it has been
set
0÷240
seconds
20
FINAL SUCTION
DELAY
SPt.d
Delay between the end of the milking
session and the opening of the s/o valve
for suction
0÷9
seconds
3
FINAL SUCTION
LENGHT
SPt.L
During opening of the s/o valve to drain
the pipe completely at the end of the
milking session
oFF ÷ 9
seconds
oFF
AUTOMATIC
RELEASE DELAY
A.r.d.
When the delay has elapsed, after
detachment, the unit is released
oFF - 5 - 15 -
30 - 45 - 60
seconds
oFF
SHUT-OFF
CLOSURE DELAY
c.S.d.
Before starting the washing cycle, the s/o
valve stays closed throughout the delay
period, in order for the system to create
vacuum
oFF ÷ 90
seconds
oFF
WASHING
FREQUENCY
diS.F
Pulsation frequency during the washing
cycle
0÷150
ppm
20
WASHING
EMPTY TIME
EMPt
Duration of empty phase during washing
with MMV
0÷99
seconds
20
WASHING FILL
TIME
FILL
Duration of fill phase during washing with
MMV
0÷99
seconds
40
DUMP VALVE
TIME
dMP.t
The dump-valve of MMV stays open for
this time for emptying the sensor
0÷2000
millisecon
ds
550 mS
CALIBRATION
CAL.M
it enables you to modify calculation of the
quantity milked. Each step is 0,1Kg
-15÷15
//
0
INITIAL PHASE
In.pH.
Select in which stage the panel must start
- dEt: start in detachment mode
- diS: start in washing mode
- LASt: start from last active stage
dEt – diS -
LASt
//
diS
UNIT OF
MEAUSEREMENT
Unit
Set to:
- Kg.C: kilograms - °Celsius
- Lb.F: pounds - ° Fahrenheit
Kg.C – Lb.F
//
Kg.C
DEFAULT
VISUALIZATION
dEF.P
Select if the display shows milking time or
milk yield
MiLk – tiME
//
MiLk
THIS MANUAL IS THE PROPERTY OF - InterPuls S.p.A.- ANY COPYING, EVEN PARTIAL, IS STRICTLY PROHIBITED
MI - 28
ACR Smart MMV - Instruction Manual, Operation and
Maintenance original instructions
5760006_02.17_EN
Milk Flow
OHM
Volt
ACR Jumpers
> 500 gr/min
700
6,10 +/- 0,07
JUMPER 1 CLOSED
JUMPER 2 CLOSED
300 gr/min
1270
6,20 +/- 0,07
JUMPER 1 OPEN
JUMPER 2 CLOSED
100 gr/min
2000
6,32 +/- 0,07
JUMPER 1 CLOSED
JUMPER 2 OPEN
< 100 gr/min
2660
6,42 +/- 0,07
JUMPER 1 OPEN
JUMPER 2 OPEN
JUMPER 2 - OPEN
JUMPER 1 - CLOSED
6 GENERAL RECCOMENDATION
Positioning 6.1
Make sure that the volumetric milk meter MMV or the flow sensor HFS are in vertical position
Sensitivity (only with HFS) 6.2
The ACR panel is designed to detect milk flows below the 100 gr/min limit (preferably with the HFS sensor).
It is possible (but NOT recommended) to increase or decrease this threshold via the jumpers on the board.
CAUTION
Power off 6.3
At the end of washing phase it’s recommended to power off the ACRSmart MMV panels to
avoid that the coils of control valves stay powered for long time and being damaged. Upon
start-up, the panel may restart in washing phase or detachment phase according to the
parameter In.p.
THIS MANUAL IS THE PROPERTY OF - InterPuls S.p.A.- ANY COPYING, EVEN PARTIAL, IS STRICTLY PROHIBITED
MI - 29
5760006_02.17_EN
ACR Smart MMV - Instruction Manual, Operation and
Maintenance original instructions
Type of system
Recommended settings
High line
Decrease parameter Continuous flow time
M.d.F. = 0,3 seconds
Low line
Decrease parameter Final delay
Fin.d. = 8 secondi
Sheep and goats
Decrease parameter Continuous flow time
M.d.F. = 0,2 seconds
Decrease parameter Final delay
Fin.d. = 8 seconds
If the system continues to detach too soon, open
both jumpers
Problem
Cause
Solution
The unit is detached too soon
Incorrect setting of Final delay,
Detachment flow, Continuous flow
time.
Increase parameter Fin.d. (Final
delay).
With MMV, decrease parameter
dEt.F (Detachment flow)
With HFS, decrease parameter
M.d.F. (Continuous flow time.)
The unit is detached too late
Incorrect setting of Final delay,
Detachment flow, Continuous flow
time.
Decrease parameter Fin.d. (Final
delay).
With MMV, increase parameter
dEt.F (Detachment flow)
With HFS, increase parameter
M.d.F. (Continuous flow time.)
The Milk Meter MMV underrates
or overrates the milk yield
Foreign bodies inside the MMV
Check that there are no foreign
bodies, such as straw, inside the
sensor
Wrong calibration parameter
See chapter 4.10 Calibration
(with MMV)
The dump-valve time of MMV is
not enough for emptying
completely the sensor
Increase parameter dMP.t (Dump
valve time)
During washing FILL phase, some
sensors are not completely filled
There’s no enough water
increase parameter FiLL (Fill
Time) on these panels (see
chapter 4.2.2 Washing with Milk
Meter)
Configurations (only with HFS) 6.4
Troubleshooting 6.5
THIS MANUAL IS THE PROPERTY OF - InterPuls S.p.A.- ANY COPYING, EVEN PARTIAL, IS STRICTLY PROHIBITED
MI - 30