IRKD600.. Series
2
ELECTRICAL SPECIFICATIONS
Voltage Ratings
Voltage V
RRM
, maximum repetitive V
RSM
, maximum non- I
RRM
max.
Type number Code peak reverse voltage repetitive peak rev. voltage @ T
J
max.
VVmA
08 800 900
12 1200 1300
16 1600 1700
20 2000 2100
IRKD600.. 50
I
F(AV)
Maximum average forward current 600 A 180° conduction, half sine wave
@ Case temperature 82 °C
I
F(RMS)
Maximum RMS forward current 1120 A 180° conduction, half sine wave @ TC = 82°C
I
FSM
Maximum peak, one-cycle forward, 19.0 KA t = 10ms No voltage
non-repetitive surge current 20.1 t = 8.3ms reapplied
16.2 t = 10ms 100% V
RRM
17.2 t = 8.3ms reapplied Sinusoidal half wave,
I
2
t Maximum I2t for fusing 1805 KA2s t = 10ms No voltage Initial TJ = TJ max.
1683 t = 8.3ms reapplied
1319 t = 10ms 100% V
RRM
1230 t = 8.3ms reapplied
I
2
√t Maximum I2√t for fusing 18050 KA2√s t = 0.1 to 10ms, no voltage reapplied
V
F(TO)1
Low level value of threshold voltage 0.70 V (16.7% x π x I
F(AV)
< I < π x I
F(AV)
), TJ = TJ max.
V
F(TO)2
High level value of threshold voltage 0.77 (I > π x I
F(AV)
), TJ = TJ max.
r
f1
Low level value of forward slope resistance 0.28 mΩ (16.7% x π x I
F(AV)
< I < π x I
F(AV)
), TJ = TJ max.
r
f2
High level value of forward slope resistance 0.25 (I > π x I
F(AV)
), TJ = TJ max.
V
FM
Maximum forward voltage drop 1.24 V Ipk = 1800A, TJ = 25°C, tp = 10ms sine pulse
Parameter IRKD600.. Units Conditions
Forward Conduction
V
INS
RMS isolation voltage 3000 V t = 1 s
I
RRM
Maximum peak reverse and off-state 50 mA TJ = TJ max., rated V
RRM
applied
leakage current
Parameter IRKD600.. Units Conditions
Blocking