International Power Sources ZCA6C01PAPDI, ZCA6C01PAPDL, ZCA6C01PAPDM, ZCA6C16M, ZCA6C17I Datasheet

...
Input
AC Input Voltage 85-264 VAC Input Frequency 47-63 Hz DC Input Voltage 48 VDC nominal (optional) Power Factor 0.99 Harmonic Current Meets EN61000-3-2 Inrush Current Limited to 30A peak Input Protection Internal 15A fuse
Output
Output Voltage 1.8 VDC to 12 VDC Output Power 600W Output Voltage Adj ±5% min, See models chart Minimum Load 0 minimum load for all outputs Line/Load Regulation • ±2% for V1, V2 and V3, ±3%
for V4 and V5
Ripple & Noise >2.5V output: 50mV or 1% whichever
is greater <=2.5V output: 2% maximum
Transient Response 4% max deviation, 300 µs recovery
time for a 25% load change Temperature Co-eff. 0.02%/°C Hold Up Time 20ms minimum Remote Sense Up to 0.25 V compensation on V1, V2
and V3 Overvoltage V1, V2 and V3 only, recycle
Protection input to reset Overcurrent Standard with auto recovery
Protection Overtemperature Logic high signal for overtemp
Protection conditions Current Sharing ±10% for V1, V2 and V3 with
“H” option
General
Efficiency 75% typical at full load Power Density 6.8 W/in
3
MTBF 200,000 hrs per Bellcore Isolation Voltage 3000 VAC Input to Output
1500 VAC Input to Ground 500 VAC Output to Ground
Signals PSU Enable, AC Fail, DC OK,
Global Inhibit, overtemp LED Indicators 2 status indicators Size 5.0” x 11.0” x 1.6”. Weight 3.3 lbs (1.5 kgs.)
Environmental
Operating 0°C to 70°C, Full power to 50°C Temperature derate from 50°C to 70°C
at 2.5%/°C Cooling 3 Internal ball bearing fans Humidity <95% RH, non-condensing Storage Temperature • -40°C to +85°C
Safety and EMC
Safety Approvals UL1950, CSA C22.2 No 950 per cUL,
EN60950 CE Mark LVD EMI/EMC EN61000-3-2, -3, EN55022 and FCC
20780 part 15J Class B conducted
with rack, Class A stand alone Immunity & Surge Meets EN61000-4-4, -5
600 Watts
ZC Series
Configurable Power Supply
Specification
Intelligent Design Quality Product
XPiQ inc.
Meets EN61000-3-2, -3
Up to 5 Outputs Plus 5V Standby
Low Voltage Outputs Down to 1.8V
Hot Swap or Chassis Mount
Oring Diodes On All Outputs
(Hot Swap Modules)
1U, 19” Rack Mount for 2 units
International Safety Approvals with CE (LVD)
PH: 508 429.9883
FAX: 800 226.2100
Email: sales@xpiq.com
Holliston, MA 01746 USA
www.XPiQ.com
ZC6.qxd 6/6/03 4:03 pm Page 1
Mechanical Details
CODE V1 V2 V3 CODE V4 CODE V5
01 1.8 V @ 70 A 2.5 V @ 50 A 12 V @ 10A PA +3.3 V @ 3 A PD +1.8 V @ 3 A 02 1.8 V @ 70 A 3.3 V @ 50 A 12 V @ 10A NA -3.3 V @ 3 A ND -1.8 V @ 3 A 03 1.8 V @ 70 A 5.0 V @ 50 A 12 V @ 10A PB +5.0 V @ 3 A PE +2.5 V @ 3 A 04 2.5 V @ 100 A - 12 V @ 10A NB -5.0 V @ 3 A NE -2.5 V @ 3 A 05 2.5 V @ 70 A 3.3 V @ 50 A 12 V @ 10A PC +12.0 V @ 3 A PF +3.3 V @ 3 A 06 2.5 V @ 70 A 5.0 V @ 50 A 12 V @ 10A NC -12.0 V @ 3 A NF -3.3 V @ 3 A 07 3.3 V @ 100 A - 12 V @ 10A - - PG +5.0 V @ 3 A 08 3.3 V @ 70 A 2.5 V @ 50 A 12 V @ 10A - - NG -5.0 V @ 3 A 09 3.3 V @ 70 A 5.0 V @ 50 A 12 V @ 10A - - PH +5.2 V @ 3 A 10 5.0 V @ 100 A - 12 V @ 10A - - NH -5.2 V @ 3 A 11 5.0 V @ 70 A 2.5 V @ 50 A 12 V @ 10A - - - ­12 5.0 V @ 70 A 3.3 V @ 50 A 12 V @ 10A - - - -
13 1.8 V @ 70 A 2.5 V @ 50 A 5 V @ 10A XX N/C PD +1.8 V @ 3 A 14 1.8 V @ 70 A 3.3 V @ 50 A 5 V @ 10A - - ND -1.8 V @ 3 A 15 2.5 V @ 100 A 5 V @ 10A - - - ­16 2.5 V @ 50 A 3.3 V @ 50 A 5 V @ 10A - - - ­17 3.3 V @ 100 A 5 V @ 10A - - - ­18 2.5 V @ 50 A 2.5 V @ 50 A 5 V @ 10A - - - -
ORDERING CODES ZC
1. For module codes 13 to 18, V4 may have an unregulated output but this output is not useable. XX is the only option code available for V4 and only ±1.8V output is available for V5.
2. V4 is user adjustable from 2.8 VDC to 14.75 VDC codes define setpoint at factory.
3. V5 is user adjustable from 1.7 VDC to 8.12 VDC codes define setpoint at factory.
Notes
PART NUMBER ORDERING SCHEME
Series AC or DC Hotswap or V1-V3 Polarity V4 Output Polarity of V5 Output Option
Input Chassis Code of V4 Code V5 Code Code
ZC A6=AC H=Hotswap 01 to 18 P = Positive A to C P = Positive D to H L = Low Leakage
D6=DC C=Chassis N = Negative N = Negative I = I
2
C Module
M = Low Leakage
&12C
Example: ZCA6H06NCNG is AC input, Hotswap chassis with V1 = 2.5V/70A, V2 = 5V/50A, V3 = 12V/10A, V4 = -12V/3A, V5 = -5V/3A.
* Note:
Vertical blackplane mounting may not allow for sufficient airflow. Horizontal backplane, or additional spacing with a vertical backplane is recommended.
PH: 508 429.9883
FAX: 800 226.2100
Email: sales@xpiq.com
Holliston, MA 01746 USA
www.XPiQ.com
ZC6.qxd 6/6/03 4:03 pm Page 2
Loading...
+ 2 hidden pages