International Power Sources UP0651S-02, UP0651S-01, UP0653S-04, UP0653S-03, UP0653S-02 Datasheet

...
68
DESCRIPTION
The UP065 Series are compact open PCB type 65 watt AC/DC switching power supplies. Utilizing the latest technology and components, these units deliver 65 watts of power in only a 3" x 5" package. The UP065 Series accepts a 90-264VAC input without the need for straps or jumpers. The main and third outputs are well regulated to within ±1 % while output #2 has significant pulse current capability which make these units ideal for a number of applications. All models are approved to UL, CSA and TUV (per IEC) requirements.
NEW • COMPACT 3”X 5” SIZE
• UNIVERSAL INPUT
FEATURES
Small size 3” x 5” x 1.2”
Universal input
75% minimum efficiency
Built-in EMI filter
Continuous short circuit protection
OUTPUT VOLTAGE/CURRENT RATINGS CHART
Output #1 Output #2 Output #3
Model Vnom Imin Imax Imax Imax3Vnom Imin Imax Imax Imax3Vnom Imin Imax Imax Imax
3
UP0651S-01 5V 0A 11A N/A 14A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A UP0651S-02 12V 0A 5.4A N/A 6.5A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A UP06515-03 15V 0A 4.3A N/A 5.2A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A UP0651S-04 24V 0A 2.7A N/A 3.3A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A UP0653S-01 +5V 0A 5.0A
1
6.0A29.0A +12V 0A 2.0A12.5A23.75A
4
-12V 0A 0.5A10.5A21.0A
UP0653S-02 +5V 0A 5.0A
1
6.0A29.0A +12V 0A 2.0A12.5A23.75A
4
-5V 0A 0.5A10.5A21.0A
UP0653S-03 +5V 0A 5.0A
1
6.0A29.0A +15V 0A 1.6A12.0A23.0A -15V 0A 0.5A10.5A21.0A
UP0653S-04 +5V 0A 5.0A
1
6.0A29.0A +24V 0A 1.0A11.25A21.9A
4
-12V 0A 0.5A10.5A21.0A
NOTES:
1. Natural convection cooled with 55W max. total output power.
2. Forced air cooled 20CFM at 1 atmosphere with 65W max. total output power.
3. Peak output current lasting less than one minute with duty cycle less than 5%. Total output power must not exceed 80 watts during peak loading, output regulation may exceed rated limits.
4. The +12V output on all models will accept pulse load currents up to 5A for disk drive applications. The +24V will accept pulse load currents up to 2.5A (for less than 500mS at 10% duty cycle). The average current must be less than the maximum current.
International Power Sources, Inc.
65 WATT
SWITCHING
POWER SUPPLY
69
GENERAL SPECIFICATIONS
All specifications are typical at nominal line, full load, and 25°C.
Efficiency: 75% minimum Switching frequency: 80 kHz Hi-pot isolation: 3750 VAC from input to output Line regulation: ±0.5% (See note 3) Load regulation: ±1% for outputs 1 and 3; ±3%
for output 2 (See note 4)
Cross regulation: ±4% for output 2; ±1% for output 3
(See note 5) Operating temperature: 0°C to +70°C Derating (50°C to 70°C): 2%/°C Temperature coefficient: ±0.02%/°C Storage temperature: -40°C to +85°C Humidity, non-condensing: 0 to 95% RH EMI filter (on board): Meets VDE/FCC Class B
conducted emission limits.
INPUT SPECIFICATIONS
Input voltage: 90 to 264 VAC Input frequency: 47 to 63 Hz Inrush current: 40A max. (cold start) Hold-up time: 16ms
OUTPUT SPECIFICATIONS
Voltage adjustment:
+5VDC primary output (V1) Adjustable ±5% Auxiliary output (V2,V3) Fixed ±5% (See note 2)
Total output power:
Convection cooled single output 65W Convection cooled triple output 55W
Forced air triple output 65W @ 20CFM Design topology: Flyback Overvoltage protecton: Main output only Overload protection: 120 to 200% of rated value Short circuit protection: Continuous Ripple and noise: 1% peak-peak max. (See note 6)
NOTES:
1. Replace input line fuse with the same type and rating. Recommended fuse is 3A/250VAC slo-blo.
2. Output tolerance is measured by setting the +5V output to its exact value (ie 5.000V). With the power supply output loaded as follows: +5V/6A, +12V/2.5A, +24V/1.25A, -12V/0.5A or -5V/0.5A any adjustment on the +5V will cause the auxillary outputs to rise or fall proportionally.
3. Line regulation is measured at nominal load and the input voltage varied from 90-132 VAC or 180-260 VAC.
4. Load regulation is measured at 115 VAC or 230 VAC input. The output being measured is varied from 30% to 100% of full load. All other outputs are loaded to 50% of full load.
5. Cross regulation is measured with a +5V at 6A load. Note: The effects of load and cross regulation are not cumulative and may actually act to cancel each other in an operating system environment.
6. Peak-to-peak and RMS metering equipment shall have a 20MHz response with probes and cables maintaining frequency response from 200Hz to 200MHz bandwidth. Output ripple and noise spikes are measured directly at the output pins of the power supply without the use of the probe ground clip.
ALL DIMENSIONS IN INCHES (mm) TOLERANCE .XX =+ 0.05
.XXX=+0.020
PIN CHART
MECHANICAL SPECIFICATIONS
Model PIN 1 2 3 4 5 6
UP0651S-XX
OUTPUT OUTPUT OUTPUT
COMMON COMMON COMMON
#1 #1 #1
UP0653S-XX
OUTPUT OUTPUT OUTPUT
COMMON COMMON
COMMON
#2 #1 #1 #3
Your Source of Power ...
260 Hopping Brook Road, Holliston, MA 01746
TEL: (508) 429-4440 FAX: (800) 226-2100
http://www.intlpower.com
International
Power Sources, Inc.
CN1 INPUT CONNECTOR MOLEX 09-50-3031 WITH SECOND PIN REMOVED
CN2 OUTPUT CONNECTOR MOLEX 09-50-3061
MOLEX MATING CONNECTOR MOLEX 2139 SERIES
HOUSING WITH 2478 SERIES CRIMP TERMINALS CN3 INPUT GROUND TAB. TAB SIZE 4.8 x 0.5(mm)
Loading...