GENERAL SPECIFICATIONS
All specifications are typical at nominal line, full load, and 25°C.
Efficiency: See Ratings Chart
Hold-up time: 10 msec at 115 VAC
Line regulation: ±1% maximum
Inrush current: 30 amps @110 VAC
Withstand voltage: 3000 VAC from input to output
1500 VAC from input to ground
Insulation resistance: 10 Mohm minimum from output
to ground
Operating temperature: 0°C to +50°C*
Storage temperature: –10°C to +70°C
MTBF: 50,000 hours minimum at full load
at 25°C ambient
EMI requirements:
Meets conduction and radiated limits of:
a) FCC Part 15 J Class B
b) CISPR 22 Class B
Safety requirements: Approved to:
a) UL 1310
b) CSA C22.2 No. 22.3
c) EN60950 per TUV
INPUT SPECIFICATIONS
Input voltage: 90 to 264 VAC
Input frequency: 47 to 63 Hz
Input current: 0.3A (rms) for 110 VAC
OUTPUT SPECIFICATIONS
Output voltage: See Rating Chart
Output current: See Rating Chart
Output power range: 0 to 15 Watts
Ripple and noise: See Rating Chart
Overvoltage protection: See Rating Chart
Overcurrent protection: All outputs protected to short
circuit conditions (auto recovery)
Temperature coefficient: All outputs ±0.04%/°C maximum
Transient response: Maximum excursion of 4% on all
models, recovering to 1% of final
value within 200us after a step
load change of 50% to 100% of
rated load.
* Derate from 100% load at 40°C to 66% load at 50°C.
MECHANICAL SPECIFICATIONS
NOTE:
1. Dimensions shown in inches.
2. Weight: 8 ounces approximate.
3. Output connector is 5.5mm outer diameter
barrel. Inner diameter is 2.5mm with center
positive (+) /outer shell negative (-) polarity.
4. Output cable length is 72.0”.
5. Contact factory for optional connectors.
6. Wall mount versions available (consult factory).
83
Your Source of Power ...
260 Hopping Brook Road, Holliston, MA 01746
TEL: (508) 429-4440 FAX: (800) 226-2100
http://www.intlpower.com