Intermec TZ2400 Quick Reference Manual

Page 1
Specifications
Electrical requirements Input voltage: 85 to 264 VAC
Frequency: 47 to 63 Hz
Application Intermec lithium-ion battery pack
(Part No. 063278 or Part No. 068537)
Charge cycle Current limit: 2.0 Amps maximum
Float voltage: 8.2V ± 100 mV
Operating environment Temperature: 0ºC to 40ºC (32ºF to 104ºF)
Storage environment Temperature: -20ºC to 60ºC (-4ºF to 140ºF)
Dimensions Approximately 51 x 114 x 165 mm (2 x 4.5 x 6.5 in)
Design and specifications are subject to change without notice.
Warning
To prevent fire or electric shock, do not expose the battery charger to rain or moisture.
Avertissement
Pour éviter des risques d’incendie ou de choc électrique, ne pas exposer le chargeur de la batterie à la pluie ou à l’humidité.
Ordering Power Cords for the Battery Charger
The AC power cord is ordered separately. If you have not already done so, contact your Intermec sales representative and order one of these Intermec power cords:
Australia, New Zealand, and China
Part No. 586281
Denmark
Part No. 586283
Europe
Part No. 586267
Italy and Chile
Part No. 586282
North America and Central America
Part No. 586105
Switzerland
Part No. 586276
United Kingdom
Part No. 586266
TZ2400 Battery Charger Quick Reference Guide
The TZ2400 battery charger lets you simultaneously charge up to four battery packs for the TRAKKER
Antares 2420 and 2425 terminals and Intermec
5020 Data Collection PC. This guide describes how to install and use the battery charger. Before using the
charger, please read this guide thoroughly and retain it for future reference. For help managing battery power, see your TRAKKER Antares 2420 and 2425
Terminal User’s Manual (Part No. 064024) or 5020 Data Collection PC User's Manual (Part No. 068975).
Choosing a Location for the Battery Charger
Choose an appropriate location for the charger using these guidelines:
Locate a flat, stable, and clean surface that is within 1.5 m (5 feet) of an
electrical source.
Make sure there is easy access to the external power supply jack on the
battery charger and to load and unload batteries.
Connecting the Power Supply
The battery charger uses an autoranging external power supply. Plug the external power supply connector into the jack on the back of the battery charger and then connect the AC power cord (ordered separately) to the power supply and to an AC outlet.
Charging a Battery Pack
You can charge up to four Intermec-labeled battery packs (Part No. 063278 or Part No. 068537) simultaneously, using any slot. The charging time depends on the condition of the battery. Usually a battery is fully charged in less than 3 hours.
Loading and Unloading a Battery Pack Into the Charger
Align the battery pack with a battery slot on the charger (as shown in the illustration) and slide the battery pack down until it fits firmly in the charger.
To unload a battery pack from the charger, simply pull it out of the battery slot. You can unload and use a battery pack before it has been fully charged.
6001 36th Avenue West P.O. Box 4280 Everett, WA 98203-9280
© 1999 Intermec All Rights Reserved
P/N 064213-004
Page 2
Using the Battery Charger
Lithium-ion battery pack
TZ2400 battery charger
External power supply
242XIS.001
Status light
AC power cord connector
Note: AC power cord is ordered separately.
External power supply connector
External power supply jack
Interpreting the Status Light
Each charger slot has a status light that indicates the status of the battery pack.
Red
The battery pack is charging.
Green
The battery pack is fully charged.
Red flashing
There is a problem with the battery pack.
Off
The battery slot is empty.
Important Recommendations
Use only Intermec-labeled lithium-ion battery packs (Part No. 063278 or Part
No. 068537) in the battery charger.
Charge the battery pack immediately before use, or at least within a couple of
days before use.
Remove the battery pack from the charger within 24 hours after charging is
completed.
For maximum battery efficiency, the recommended temperature range when
charging is 10ºC to 30ºC (50ºF to 86ºF).
Be sure nothing metallic comes into contact with the battery charger contacts.
Do not disassemble the charger. There are no user-serviceable parts in the
charger.
While the charger is in use, it becomes warm. This is normal.
Do not place the charger in locations that are extremely hot or cold, dusty or
dirty, very humid, or subject to vibration.
If the status light continuously flashes or fails to light when a battery pack is
in the slot, if any part of the charger appears worn or damaged, or if any difficulty arises while using the battery charger, unplug the battery charger immediately and contact your Intermec service representative.