Intermec CV60, 851-040-001, 851-041-002, 851-070-001 Installation Manual

Page 1
Installation
Mobile DC-DC Uninterruptible Power Supply
Guide
Page 2
2 Mobile DC-DC Uninterruptible Power Supply Installation Guide
Corporate Headquarters Technical Communications Department 6001 36th Ave. W. 550 Second Street SE
Everett, WA 98203 Cedar Rapids, IA 52401 U.S.A. U.S.A.
www.intermec.com
The information contained herein is proprietary and is provided solely for the purpose of allowing customers to operate and service Intermec-manufactured equipment and is not to be released, reproduced, or used for any other purpose without written permission of Intermec.
Information and specifications contained in this document are subject to change without prior notice and do not represent a commitment on the part of Intermec Technologies Corporation.
E 2003 by Intermec Technologies Corporation. All rights reĆ served.
The word Intermec, the Intermec logo, Norand, ArciTech, CrossBar, Data Collection Browser, dcBrowser, Duratherm, EasyCoder, EasyLAN, Enterprise Wireless LAN, EZBuilder, Fingerprint, i-gistics, INCA (under license), InterDriver, Intermec Printer Network Manager, IRL, JANUS, LabelShop, Mobile Framework, MobileLAN, Nor*Ware, Pen*Key, Precision Print, PrintSet, RoutePower, TE 2000, Trakker Antares, UAP, Universal Access Point, and Virtual Wedge are either trademarks or registered trademarks of Intermec Technologies Corporation.
Throughout this manual, trademarked names may be used. Rather than put a trademark ( or ®) symbol in every occurrence of a trademarked name, we state that we are using the names only in an editorial fashion, and to the benefit of the trademark owner, with no intention of infringement.
There are U.S. and foreign patents pending.
Page 3
3
Mobile DC-DC Uninterruptible Power Supply Installation Guide
Description
An uninterruptable power supply (UPS) is a battery-operated power supply connected to a computer to keep the system runĆ ning during a power failure. The UPS service for Windows XP and Windows CE detects and warns users of power failures and manages a safe system shutdown when the backup power supply is about to fail.
UPS Battery Information
The UPS battery (P/N 317-075-002) requires 3-4 hours to fully charge. Remove the six screws from the UPS cover for battery access.
Note: The battery is the only user-serviceable part. Use only Intermec-approved replacement batteries for the UPS, since they are UL-approved.
Cover
RS-232 Connector
DC Input from Vehicle Battery or Power Supply
Power Connector to CV60
Power/Charge Status
LED
Remote Sense Input
(Optional Connection)
Shown with dust covers removed
Note: Visit the Intermec technical knowledge base (Knowledge Central) at http://intermec.custhelp.com to review technical information and support for batĆ tery care and use for your Intermec product.
Page 4
4 Mobile DC-DC Uninterruptible Power Supply Installation Guide
Connecting the UPS (Smart Mode)
Note: Remove the dust cover from the serial port before connecting the cable.
1 Attach the RSĆ232 cable (PN 321-593-001) to COM1 or
COM2 on the CV60 and tighten the screws to the DBĆ9 connector.
2 Connect the other end of the RSĆ232 serial cable to the
RS-232 connector on the UPS and tighten the screws.
3 Connect the cable from the UPS power OUT to the CV60
power input connector. Tighten the connector.
4 Connect the cable (PN 226-341-003, six foot cable or PN
226-341-004, three foot cable) from the vehicle battery or power supply to the dc input connector on the UPS.
Connecting the UPS (Standard)
1 Connect the cable (PN 226-341-003, six foot cable or PN
226-341-004, three foot cable) from the vehicle battery or dc-dc converter to the dc input connector on the UPS.
2 Connect the cable from the UPS power OUT to the CV60
power input connector. Tighten the connector.
Power/Charge Status LED
The LED lights when power is applied to the UPS.
S Amber: indicates UPS is charging
S Red: indicates UPS is discharging
S Green: indicates UPS is charged.
Note: Always have power to the UPS before booting the CV60. Failure to do so may cause the UPS to shut down.
Page 5
5
Mobile DC-DC Uninterruptible Power Supply Installation Guide
Remote Sense Input (Optional, CV60 only)
Use this input if you want the UPS to send a shutdown signal to the CV60 Vehicle Mount Computer.
Note: Remove the dust cover from the circular conĆ nector before installing the cable.
Installation:
1 Cut the 2 pin connector end from the cable (P/N 226-340-001)
and wire the toggle switch as shown.
2 Install the cable into the 4 pin connector.
Operation:
1 Close the switch (ON) to have the CV60 shutdown (after config
uring the UPS service in software.)
2 To remove the shutdown signal to the CV60, move the toggle
switch back to the OFF position.
3 When the battery is low, there are two thresholds that are
reached:
S the UPS will signal the CV60 to shut down via the low
battery line
S the UPS itself will shut down to conserve battery power.
(The LED turns off).
4 The UPS will awaken when external power is applied and the
battery is charged to a minimum level.
Green/White
Red
X
P/N 226-340-001
Switch
Switch Wiring Diagram
Black - No Connection
Page 6
6 Mobile DC-DC Uninterruptible Power Supply Installation Guide
Note: The toggle switch for remote sense operation is not Intermec supplied. We recommend an SPST switch (single pole single throw) rated at 24VDC at 1mA or less for the remote sense option.
Note: Use a sealed switch for high humidity and dusty environments. Follow customary electrical wiring practices when wiring the switch.
Remote Sense Cable P/N 226-340-001
X
Cut this End
J1
J2
108 +/- 3.0
Pin 1
Pin 2
Pin 1
Pin 2
Pin 4
Pin 3
Green White Red Black
J1 J2
1
2
1 2 3
4
-DC
+DC
-DC
-DC +DC +DC
Note: New cables may not adhere to the Intermec current wiring scheme. Verify individual wire colors and their equivalent connection before proceding with the UPS installation.
Page 7
7
Mobile DC-DC Uninterruptible Power Supply Installation Guide
Configuring the UPS Service
Windows XP
Double-tap the CV60 Settings icon to open the control panel applet.
1 On the UPS Service button, click Start UPS Service.
2 Check Auto Start Service when OS Start box if you want
the UPS service to start at login.
3 In Critical Level Shutdown Timeout, select Manual, or 10,
20, 30 second intervals.
4 In COM Port, select the COM port where the UPS device is
connected.
5 In Polling Frequency dialog box, set the intervals for 1 sec, 3
sec, or 5 sec.
Page 8
8 Mobile DC-DC Uninterruptible Power Supply Installation Guide
Windows CE
Double-tap the CV60 Settings icon to open the control panel applet.
UPS
Select the UPS tab and check the Enable UPS checkbox. Click the dropĆdown arrow to reset the Poll Frequency value. Check Automatic shutdown before you click its drop-down arrow to adjust its value.
Page 9
9
Mobile DC-DC Uninterruptible Power Supply Installation Guide
851-040-001 or 851-041-002 DC-DC Converters
851-070-001 DC-DC Converter
Page 10
10 Mobile DC-DC Uninterruptible Power Supply Installation Guide
Page 11
11
Mobile DC-DC Uninterruptible Power Supply Installation Guide
Page 12
12 Mobile DC-DC Uninterruptible Power Supply Installation Guide
Corporate Headquarters
6001 36th Avenue West Everett, Washington 98203
tel 425.348.2600
fax 425.355.9551
www.intermec.com
*962000030A*
*962-000-030A* REV A
Mobile DC-DC Uninterruptable Power Supply - August 2004
U.S.A
Loading...