WEATHERPROOF RECEPTACLE COVER INSTALLATION INSTRUCTIONS
This device must be mounted in accordance with all local and National Electrical Code requirements. The following illustrations are typical mounting configurations which may or may not meet your local requirements.
To assure a weatherproof seal between the cover and surfaces which are irregular such as brick or cedar siding, a l/4" minimum bead of nonhardening caulking compound of sili­cone (preferred), neoprene, urethane or polyurethane type should be placed between the weatherproof receptacle gasket and the mounting surface. (See fig. 3).
INSTALLATION
This weatherproof receptacle cover is designed to provide protection for perma­nently or semi-permanently installed appli­ances such as rotisseries, low voltage out­door lighting, holiday lighting or other such permanent or semi-permanent power requirements. This receptacle cover is designed to protect the receptacle from mois­ture “while in use” for safety and to prevent nuisance tripping of the circuit breaker. When properly closed, the recep-tacle cover will protect all receptacles from rain or other moisture whether in use or not.
This receptacle cover is designed for mount­ing on a horizontal receptacle regardless of whether it is a standard 2 outlet duplex or a 2 outlet decorator or GFI type outlet. Two inserts are included with the receptacle cover for these applications. (See Fig.1 & 2).
In order to ensure a weatherproof cover, the self-closing receptacle cover must be installed so that the hinge points are located at the top. (See Fig. 3).
1. Weatherproof cover/base (factory pre­assembled).
2. Universal insert for 2 outlet duplex recep­tacle.
3. Universal insert for GFI receptacle or dec­orator style receptacle.
4. Neoprene gasket with slits for mounting screws.
5. Baggie assembly with 4 long mounting screws and 2 short mounting screws.
CAUTION: DISCONNECT POWER TO THE RECEPTACLE AT THE CIRCUIT BREAKER PANEL BEFORE INSTALLING THIS RECEP­TACLE COVER.
GFI FIG. 1
FIG. 3
DUPLEX FIG. 2
Lockable Tab
Insert
Gasket
Cover
Base
®
To install your receptacle cover, follow the steps listed. (See figures 4, 5, 6, 7 and 8).
IF USING A POWER SCREWDRIVER, BE CAREFUL NOT TO OVER TIGHTEN THE SCREWS BECAUSE YOU WILL STRIP THE THREADS IN THE JUNCTION BOX AND/OR THE ELECTRICAL DEVICE.
1. If installation is being done on an existing receptacle, remove the existing receptacle cover and discard.
2. The mounting screws which hold the receptacle or GFI to the junction box can be removed. Do not remove receptacle wiring connections.
3. Select the proper insert and press insert into base/cover assembly. Press insert firmly into this assembly and it will remain there during the remaining assembly steps.
4. Locate gasket as required for the installa­tion. Be sure gasket is held to the back of the base/cover and insert assembly using the four projections molded on the insert to locate the gasket.
5. Mount the cover/base and insert assem­bly, hinge on top, and the existing recepta­cle to the junction box using two of the long screws provided (DO NOT OVER
TIGHTEN).
CAUTION: DISCONNECT POWER TO THE RECEPTACLE AT THE CIRCUIT BREAKER PANEL BEFORE INSTALLING THIS RECEP­TACLE COVER.
6. If mounting to an outdoor junction box or field service (FS) box, use the remaining long screws, two or four screws as required, to further secure the cover/base and insert assembly to the box. Note that holes are located in the insert for mount­ing to an FS box or any standard single gang junction box. For specially designed junction boxes, holes should be carefully drilled to line up with the holes in the junc­tion box to accommodate mounting.
7. Be sure all screws are secure but not over tightened. Then install the remaining one or two short screws into the receptacle as required.
8. Amolded tab (see Figure 8) is provided to allow for padlocking the cover closed if desired (Figure 9).
FOR BEST PROTECTION FROM RAIN OR HUMIDITY, BE SURE TO ROUTE THE CORDS THROUGH THE CORD OUTLETS IN THE COVER AND PRESS THE COVER FIRMLY UNTIL IT SNAPS CLOSED.
FULL ONE YEAR WARRANTY.
If within one (1) year from date of purchase this product fails due to a defect in material or workmanship, Intermatic Inc. will repair or replace it free of charge.
This warranty does not apply to: a) damage caused by accident, units struck by lightning, abuse, mishandling, dropping; b) units which have been subject to unauthorized repair, opened, taken apart; c) units not used in accordance with directions, d) dam­ages exceeding the cost of the product. Some states do not allow a limitation of damages so the foregoing limitation may not apply to you. This warranty gives you specific legal rights and you may also have other rights which may vary from state to state.
This warranty service is available by a) returning the product to the dealer from whom it was purchased or b) mailing postage prepaid to the address listed below. Please be sure to wrap the product securely when mailing to avoid shipping damage.