ELECTRICAL REQUIREMENTS
qualified electrician should complete all required wiring. This fixture will accept 120, 208, 240 or 277
A
volts AC and must be properly grounded for safety. A mounting suitable for outdoor use and rated for
wet locations is required. Follow all applicable electrical codes and regulations.
WARNING:
Electric shock hazard
Disconnect power at circuit breaker or fuse box before installing or servicing light.
WARNING:
USE MIN 90ºC SUPPLY CONDUCTORS.
CONNECT TO SUPPLY IN EXTERNAL JUNCTION BOX ONLY.
Fire hazard
Lamp and housing become very hot during use.
Ensure free air circulation around unit to dissipate heat.
Avoid enclosed locations and locations where flammable debris (leaves, cut grass, etc.) might collect.
Avoid locations where humans or animals might accidentally touch fixture.
WARNING:
Never operate light without securing the lens door
Explosion hazard
. When light is operating, the gas in the
lamp inner arc tube is at high pressure.
Never operate light if the fixture lens or outer glass envelope of the lamp is broken or missing.
WARNING:
Explosion hazard
Wear safety glasses and gloves when handling lamp, High Pressure Sodium outer envelope is under
vacuum and could implode.
Figure 1
Screws
Lens
Cover
Hinge
Figure 2
Install with Lamp vertical
M
OUNTING & WIRING
1. Loosen (2) screws, open, and remove fixture lens cover. Set lens cover aside to prevent damage while installing.
(See Figure 2)
2. Loosen (4) screws and remove reflector.
3. Identify supply voltage.
4. Select appropriate fixture wire to match incoming voltage. All fixtures are shipped with 277 V wire ready for
connection. If supply voltage is lower, cap wire marked 277V with appropriate twist on wire connector and strip
fixture wire marked with matching voltage. (See Figure 3)
CAP
277 V
40 V
2
208 V
120 V
OM
C
3
X
IGN-01
COM
1
X
LAMP
3
X
Figure 3
5. Feed the matching voltage fixture wire, fixture wire marked “COM”, and bare copper fixture grounding wire out of
the fixture.
6. Confirm all unused voltage fixture wires are appropriately capped within fixture body.
7. Using provided twist on or other approved connectors, connect the fixture wires to the supply wires.
a. Connect the selected voltage fixture wire to the Black (hot) supply wire.
b. Connect the White fixture wire marked “COM” to the White (neutral) supply wire.
c. Connect the bare copper (fixture ground) wire to the supply grounding wire.
8. Mount fixture to wall. Fixture should be mounted horizontal. (See Figure 2)
9. Install reflector and secure with (2) screws.
10. Screw lamp into lampholder until finger-tight.
11. Install, close, and secure lens cover with (2) screws making sure that the gasket is properly seated. To weatherproof
fixture, seal all holes in housing (mounting conduit, plugs, photocontrols, etc.) with silicone sealant.
12. To operate, restore power to the circuit and switch light on.
LAMP REPLACEMENT
CAUTION:
1. Turn off power at circuit breaker or fuse box. Allow fixture and lamp to cool.
2. Loosen (2) screws and swing hinged fixture lens door open. Remove old lamp and replace
with new lamp of correct type and wattage. Screw lamp into socket in lampholder until finger-tight.
3. Close and secure lens door, making sure that gasket is properly seated, free of debris, and
compressed to seal out moisture.
4. Turn power back on.
5. Properly dispose of lamp per manufacturer’
If within one (1) year from the date of purchase, this product fails due to a defect in material or workmanship, Intermatic Incorporated will repair or replace it, at its sole option, free of charge.
to the original purchaser only and is not transferable. This warranty does not apply to: (a) damage to units caused by accident, dropping or abuse in handling, acts of God or any negligent use; (b) units which have been
subject to unauthorized repair, opened, taken apart or otherwise modified; (c) units not used in accordance with instructions; (d) damages exceeding the cost of the product; (e) sealed lamps and/or lamp bulbs; (f) the
finish on any portion of the product, such as surface and/or weathering, as this is considered normal wear and tear; (g) transit damage, initial installation costs, removal costs, or reinstallation costs.
INTERMATIC INCORPORATED WILL NOT BE LIABLE FOR INCIDENTALOR CONSEQUENTIAL DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU. THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS OR IMPLIED WARRANTIES. ALL IMPLIED WARRANTIES,
INCLUDING
WARRANTY, AND SHALL BE OF THE SAME DURATION AS THE WARRANTY PERIOD STATED ABOVE. SOME STATES DO NOTALLOW LIMITATIONS ON THE DURATION OF AN IMPLIED WARRANTY, SO THE
ABOVE LIMITATION MAY NOTAPPLY TO YOU.
This warranty service is available by either (a) returning the product to the dealer from whom the unit was purchased, or (b) mailing the product, along with proof of purchase, postage
prepaid to the authorized service center listed below. This warranty is made by: Intermatic Incorporated/After Sales Service/7777 Winn Rd., Spring Grove, Illinois 60081-9698/815-675-7000 http://www.intermatic.com
Please be sure to wrap the product securely to avoid shipping damage.
THE W
ARRANTY
THESE INSTRUCTIONS DO NOT COVER ALLVARIATIONS IN EQUIPMENT, NOR DO THEY PROVIDE FOR ALL SITUATIONS RELATED
TO FIXTURE INSTALLATION, OPERATION OR MAINTENANCE. FOR FURTHER INFORMATION CONTACT YOUR DISTRIBUTOR OR
OF MERCHANT
INTERMATIC INCORPORATED - SPRING GROVE, ILLINOIS 60081 (815) 675-7000 www.intermatic.com
Use lamp of correct type and wattage as specified on fixture.
s recommendations.
LIMITED 1 YEAR WARRANTY
THE WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, ARE HEREBY MODIFIED TO EXIST ONLY AS CONTAINED IN THIS LIMITED
AND
ABILITY
This warranty is extended
158HL12509