Intermatic WL050MH, WL070MH User Manual

HID Wall Pack - WL Series
INSTALLATION INSTRUCTIONS Lamp Types: Metal Halide 50 Watt & 70 Watt Models: WL050MH & WL070MH
FOR OUTDOOR USE ONLY
NOT FOR USE IN HAZARDOUS ATMOSPHERES
IMPORTANT: Read instruction sheet carefully before installing fixture.
Retain instructions for future reference.
A qualified electrician should complete all required wiring. This fixture will accept 120, 208, 240 or 277 Volts AC and must be properly grounded for safety. A mounting suitable for outdoor use and rated for wet locations is required. Follow all applicable electrical codes and regulations.
WARNING:
Electric shock hazard
Disconnect power at circuit breaker or fuse box before installing or servicing light.
WARNING:
Fire hazard
USE MIN 60˚C SUPPLY CONDUCTORS. CONNECT TO SUPPLY IN EXTERNAL JUNCTION BOX ONLY. Lamp and housing become very hot during use. Ensure free air circulation around unit to dissipate heat. Avoid enclosed locations and locations where flammable debris (leaves, cut grass, etc.) might collect. Avoid locations where humans or animals might accidentally touch fixture.
WARNING:
Never operate light without securing the lens door
Explosion hazard
. When light is operating, the gas in the lamp inner arc tube is at high pressure. Never operate light if the fixture lens or outer glass envelope of the lamp is broken or missing.
WARNING:
Explosion hazard
Wear safety glasses and gloves when handling lamp. Metal Halide outer envelope is pressurized and could explode if broken.
WARNING: UV hazard (Metal Halide Lamps Only)
The type of lamp used in this fixture can cause serious skin burn and eye inflammation from short wave ultraviolet radiation if outer envelope of the lamp is broken or punctured, and the arc tube continues to operate. Do not use where people will remain for more than a few minutes. Certain types of lamps that will automatically extinguish when the outer envelope is broken or punctured are commercially available.
MOUNTING & WIRING
1. Screw the threaded mounting arm of the fixture into 1/2” NPS mounting hole on mounting device.
Tighten locknut to secure fixture. See Figure 1.
Mounting Plate
Locknut Inside Fixture
Figure 1
Screw
Hinge
Lens Cover
Figure 2
Install with lamp horizontal
MOUNTING & WIRING
1. Loosen (2) screws, open, and remove fixture lens cover. Set lens aside to prevent damage wile installing. See Figure 2)
(
2. Loosen (2) screws and remove reflector.
3. Remove locknut from mounting plate threaded nipple inside fixture. Separate mounting plate from fixture.
. Apply provided gasket to back of mounting plate for sealing against junction box.
4
5. Identify supply voltage.
6. Select appropriate fixture wire to match incoming voltage. All fixtures are shipped with 277V wire ready for connection. f supply voltage is lower, cap wire marked 277V with appropriate twist on wire connector and strip fixture wire marked
I with matching voltage (see Figure 3)
277 V
40 V
2
08 V
2
AP
C
120 V
COM
X3
I
C
X1
LAMP
GN-02
X2
OM
Figure 3
7. Feed the matching voltage fixture wire, fixture wire marked “COM”, and bare copper fixture grounding wire through the locknut and then out of the fixture.
8. Confirm all unused voltage fixture wires are appropriately capped within fixture body.
9. Feed the (3) fixture wires outside of the fixture through the threaded nipple of the mounting plate.
10. Using provided twist on or other approved connectors, connect the fixture wires to the supply wires. a. Connect the selected voltage fixture wire to the Black (hot) supply wire. b. Connect the white fixture wire marked “COM” to the White (neutral) supply wire. c. Connect the bare copper (fixture ground) wire to the supply grounding wire.
11. Install mounting plate on junction box with connections in the box.
12. Install fixture over mounting plate nipple and tighten locknut to secure fixture body to mounting. Fixture should be
mounted horizontal. (See Figure 2)
13. Install reflector and secure with (2) screws.
14. Screw lamp into lampholder until finger-tight.
15. Install, close, and secure lens cover with (2) screws making sure that the gasket is properly seated. To weatherproof
fixture, seal all holes in housing (mounting conduit, plugs, photocontrols, etc.) with silicone sealant.
16. To operate, restore power to the circuit and switch light on.
CAUTION:
(Metal Halide Lamps Only) Do not use lamp beyond manufactures rated life to reduce chance of lamp rupture.
Turn lamp off at least once for 15 minutes per week to reduce chance of lamp rupture.
LAMP REPLACEMENT
CAUTION:
1. Turn off power at circuit breaker or fuse box. Allow fixture and lamp to cool.
2. Loosen (4) screws, open, and remove fixture lens cover. Remove old lamp and replace
with new lamp of correct type and wattage. Screw lamp into socket in lampholder until finger-tight.
3. Install, close, and secure lens cover with (4) screws making sure that gasket is properly seated, free of debris, and
compressed to seal out moisture.
4. Turn power back on.
5. Properly dispose of lamp per manufacturer’s recommendations.
If within one (1) year from the date of purchase, this product fails due to a defect in material or workmanship, Intermatic Incorporated will repair or replace it, at its sole option, free of charge. This warranty is extended to the original purchaser only and is not transferable. This warranty does not apply to: (a) damage to units caused by accident, dropping or abuse in handling, acts of God or any negligent use; (b) units which have been subject to unauthorized repair, opened, taken apart or otherwise modified; (c) units not used in accordance with instructions; (d) damages exceeding the cost of the product; (e) sealed lamps and/or lamp bulbs; (f) the finish on any portion of the product, such as surface and/or weathering, as this is considered normal wear and tear; (g) transit damage, initial installation costs, removal costs, or reinstallation costs. INTERMATIC INCORPORATED WILL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU. THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS OR IMPLIED W PURPOSE, ARE HEREBY MODIFIED TO EXIST ONLY AS CONTAINED IN THIS LIMITED WARRANTY, AND SHALL BE OF THE SAME DURATION AS THE WARRANTY PERIOD STATED ABOVE. SOME STATES DO NOT ALLOW LIMITATIONS ON THE DURATION OF AN IMPLIED WARRANTY, SO THE ABOVE LIMITATION MAY NOTAPPLY TO YOU. This warranty service is available by either (a) returning the product to the dealer from whom the unit was purchased, or (b) mailing the product, along with proof of purchase, postage prepaid to the authorized service center listed below. This warranty is made by: Intermatic Incorporated/After Sales Service/7777 Winn Rd., Spring Grove, Illinois 60081-9698/815-675­7000 http://www.intermatic.com Please be sure to wrap the product securely to avoid shipping damage.
ARRANTIES.
THESE INSTRUCTIONS DO NOT COVER ALLVARIATIONS IN EQUIPMENT, NOR DO THEY PROVIDE FOR ALL SITUATIONS RELATED
TO FIXTURE INSTALLATION, OPERATION OR MAINTENANCE. FOR FURTHER INFORMATION CONTACT YOUR DISTRIBUTOR OR
INTERMATIC INCORPORATED - SPRING GROVE, ILLINOIS 60081 (815) 675-7000 www.intermatic.com
ALL
IMPLIED W
Use lamp of correct type and wattage as specified on fixture.
YEAR WARRANTY
ARRANTY
OF MERCHANTABILITY AND THE WARRANTY OF FITNESS FOR A PARTICULAR
ARRANTIES, INCLUDING
LIMITED 1
THE W
158HL12124
Loading...