Intermatic PF1202T Installation, Operation & Service Manual

Page 1
81/2
FREEZE PROTECTION FOR POOLS, SPAS AND WATERFEATURES
By
FREEZE PROTECTION FOR POOLS AND SPAS
By
®
INSTALLATION
OPERATION &
SERVICE MANUAL
MODEL: PF1202T
TWO CIRCUIT POOL EQUIPMENT CONTROL
WITH FREEZE PROTECTION IN RAINPROOF ENCLOSURE
ELECTRICAL RATING: 3 HP MAX. - 240 VOLT, 60 HZ. SUITABLE FOR POOL/SPA EQUIPMENT CONTROL
DANGER! To Reduce the Risk of Injury:
...do not permit children to operate the Control Unit or use the Pool/Spa unless they are closely supervised at all times. ...test GROUND FAULT protection regularly. If it fails to reset, DO NOT USE THE POOL or SPA! Contact a qualified service technician. ...always disconnect electricity before servicing this control or the equipment(s) connected to it. THIS CONTROL IS NOT
TO BE USED AS A POWER DISCONNECT.
READ, FOLLOW & SAVE THIS INSTRUCTION MANUAL
GENERAL INFORMATION
This Pool Equipment Control is designed to automatically operate the Filter Pump, Cleaner Pump and also to provide freeze protection for the pool equipment. Nevertheless this product is not intended to be a substitute for insulation, coverings, or maintenance.
THE FILTER PUMP TIME SWITCH is located in the upper left side of the enclosure and operates the Filter Pump, as set by the trippers on the yellow dial, on a 24 hour schedule. For setting the schedule, refer to page 3 of this Manual.
THE CLEANER PUMP TIME SWITCH is located in the upper right side of the enclosure and operates the Cleaner Pump (Booster Pump). The trippers of this Time Switch should be set so that the operation of the Cleaner Pump falls within the operation of the Filter Pump. To avoid equipment damage, the two Time Switches are interlocked and the Cleaner Pump would not operate unless the Filter Pump is already operating.
Page 2
Page 3
ITEM
PT
. NO. DESC. QUAN.
DR.: SRB 8/19/2005
INTERMATIC INCORPORATED
CHKD.:
TF 8/22/2005
SCALE: NAME:
INST SHT - INSTALL, PF1202T
APPROVED
MA
TL.:
WHITE P
DMB 8/22/2005 FINISH:
BLACK PRINTING INK
1 RELEASED TO ELEC. DATA
HEAT TREAT:
LET. REVISION SIGN. MODEL SUPERSEDES:
DIM
TOL
SEE B/M FOR ALL PART NUMBERS & QUANTITIES
Page 4
FREEZE PROTECTION FOR POOLS, SPAS AND WATERFEATURES
By
WIRING
DIAGRAM
ALTERNATE WIRING FOR
TWO INDEPENDENTLY
WIRED PUMPS
W
ARRANTY
If within one (1) year from the date of installation, this product fails due to a defect in material or workmanship, Intermatic Incorporated will repair or replace it free of charge.
The warranty does not cover labor for removal or reinstallation and does not apply to: (a) damage caused by accident, abuse, mishandling, or dropping; (b) a unit which has been subject to unauthorized repair; (c) units not used in accordance with directions; (d) damages exceeding the cost of the product./ Some states do not allow a limitation of damages so the foregoing warranty may not apply to you.
This warranty gives you specific legal rights and you may also have other rights which vary from state to state.
This warranty service is available, if the defective product or its defective component is returned with proof of purchase and date of installation, either (a) to the dealer from whom the unit was purchased or (b) by shipping prepaid to Intermatic, Incorporated, Intermatic Plaza, Spring Grove, Il. 60081-9698.
240 V.
CLOCK
MOTOR
240 V.
CLOCK
MOTOR
Filter Control T
ime Switch
Cleaner Control T
ime Switch
NOTE: Ground connections
are not shown and vary with installation.
T
o Filter
Pump
To 240 V
Breaker
To Cleaner
Pump
TB1
T
eam
Block
Relay
T. Stat
Equipment Ground
Loading...