Intermatic 158WF12662REF User Manual

WF403
GENERAL INSTRUCTIONS FOR WATERFALL USE
. Unpack the product, wipe off dust with a damp cloth. Take out all
1
accessories: pump and light with adapter.
2. Familiarize yourself with the pump. Turn valve on pump counter clockwise placing the handle in a horizontal position for maximum water flow. Turn the valve on the pump in a vertical position for minimum water flow.
NOTE: It is recommended the pump be set at its highest flow during assembly
and later adjusted to a lower setting if desired. Be sure to unplug pump before adjusting flow setting.
WARNING: RISK OF ELECTRICAL SHOCK
Do not connect to any voltage other than that shown on the pump.
• This pump is supplied with a grounding conductor and grounding-type attach­ment plug. To reduce the risk of electric shock, be certain that it is connected only to a properly grounded, grounding-type receptacle.
• The national electric code requires that a ground fault circuit interrupter (GFCI) be used in the branch circuit supplying fountain pumps and other pond equip­ment. See your electrical supplies dealer for this device.
• If the supply cable is damaged it can not be replaced and the pump unit should be discarded.
WARNING: RISK OF FIRE
Do not use with water above 30˚C.
Do not pump flammable liquids.
3. Attach the pump to the connector tube on the fountain and place the pump inside the fountain. Place the light in socket at base of fountain. Run the cord through the hole into the base of the fountain out the back, lay with power cord from pump. Connect cord from light to A/C adapter and tighten.
NOTE: Do not let pump run when NOT submerged in water. Doing so may damage the pump. Always submerge the pump in water first, and then plug in the unit.
4. Fill base with tap water to approximately 1/2" above pump. Distilled water is recommended in order to minimize mineral deposits.
NOTICE: Do not place outdoors in weather conditions below 32˚F, may cause water to freeze.
5. Plug cord into 120V household outlet. Turn pump on to verify flow making sure it is not too high and everything is operating correctly. Arrange river rocks on top of plate.
NOTE: Ensure that the electrical cord loop below the electrical outlet.” This will prevent water from running down the cord into the electrical outlet.
ARNING
W
Do not connect with wet hands.
Lens and shade get hot.
IMPORTANT SAFETY INSTRUCTIONS LIGHTED LAMP IS HOT TO REDUCE THE RISK OF FIRE OR INJURY TO PERSONS:
• Turn off/unplug and allow to cool before replacing lamp.
• Lamp gets HOT quickly! Contact only switch/plug when turning on.
Do not touch the lamp at any time. Use a soft cloth. Oil from skin may damage lamp.
Do not operate the luminaire fitting with a missing or damaged shield.
:
Keep lamp away from materials that may burn.
Do not touch hot lens, guard, shade, or enclosure.
MAINTAINING CLEANLINESS AND LIFE OF WATERFALL & PUMP
1. Ensure water pump is kept clean and free of debris. We recommend using distilled water with this product.
NOTE: To clean pump, first make sure pump is UNPLUGGED from 120V circuit and remove front plate. After removing the
ront plate, the impeller holder must be removed. Remove the
f impeller from the pump and check for debris and/or dirt. Rinse impeller and pump under cold water. Reassemble.
Front Plate
Regulator
Impeller Holder
Impeller
Seal Ring
Motorhead
2. Periodically change water and clean the structure of the waterfall with a mixture of vinegar and cold clean water.
3. Add water to waterfall periodically to keep water level at an optimum
Shaft
Suction Bracket
level (approximately 1/2” above pump) to avoid shortening the life of the pump. Water level should completely cover pump at all times.
NOTE: Never let the pump run dry. This will shorten the life of the pump.
4. To store waterfall after use, unplug the waterfall from the electrical outlet, empty the water, and store in a cool dry
place.
TROUBLESHOOTING
1. If jets do not spray correctly, check water level and add if necessary or clean jet holes to unclog any deposits.
2. If pump fails to operate, check the circuit breaker, or try a different outlet to make sure the pump is getting electrical
power.
3. If the pump gurgles, spews, or “burps”, check the water level to make sure the pump has enough water to function.
4. If water is splashing outside of the waterfall, adjust the flow control valve to a lower setting.
LIMITED ONE YEAR WARRANTY
If within one (1) year from the date of purchase, this product fails due to a defect in material or workmanship, Intermatic Incorporated will repair or replace it, at its sole option, free of charge. This warranty is extended to the original household purchaser only and is not transferable. This warranty does not apply to: (a) damage to units caused by accident, dropping or abuse in handling, acts of God or any negligent use; (b) units which have been subject to unauthorized repair, opened, taken apart or otherwise modified; (c) units not used in accordance with instructions; (d) damages exceeding the cost of the product; (e) sealed lamps and/or lamp bulbs, LED’s and batteries; (f) the finish on any portion of the product, such as surface and/or weathering, as this is considered normal wear and tear; (g) transit damage, initial installation costs, removal costs, or reinstallation costs.
INTERMATIC INCORPORATED WILL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU. THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS OR IMPLIED WARRANTIES. ALL IMPLIED WARRANTIES, INCLUDING THE WARRANTY OF MERCHANTABILITY AND THE WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, ARE HEREBY MODIFIED TO EXIST ONLY AS CONTAINED IN THIS LIMITED WARRANTY, AND SHALL BE OF THE SAME DURATION AS THE WARRANTY PERIOD STATED ABOVE. SOME STATES DO NOT ALLOW LIMITATIONS ON THE DURATION OF AN IMPLIED WARRANTY, SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU.
This warranty service is available by either (a) returning the product to the dealer from whom the unit was purchased, or (b) mailing the product, along with proof of purchase, postage prepaid to the authorized service center listed below. This warranty is made by: Intermatic Incorporated/After Sales Service/7777 Winn Rd., Spring Grove, Illinois 60081-9698/815-675-7000 http://www.intermatic.com Please be sure to wrap the product securely to avoid shipping damage.
AUTHORIZED SERVICE CENTER /CENTRO DE SERVICIO AUTORIZADO / CENTRE DE SERVICE AGRÉÉ
Intermatic Incorporated
After Sales Service
7777 Winn Road
Spring Grove, IL 60081-9698
158WF12662
Loading...