WF401
GENERAL INSTRUCTIONS FOR WATERFALL USE
1. Unpack the product, wipe off dust with a damp cloth. Take out all
accessories: pump and adapter. Spare bulb included.
2. Familiarize yourself with the pump. The switch located at the front of it controls
the water flow. The flow is indicated by a max and min sign. To increase flow,
move switch in the direction of max. To decrease flow, move the switch toward
min.
CAUTION: This pump has been evaluated for use with water only.
NOTE: It is recommended the pump be set at its highest flow during assembly
and later adjusted to a lower setting if desired. Be sure to unplug pump before
adjusting flow setting.
WARNING: RISK OF ELECTRICAL SHOCK
• Do not connect to any voltage other than that shown on the pump.
This pump is supplied with a grounding conductor and grounding-type attach-
•
ment plug. To reduce the risk of electric shock, be certain that it is connected
only to a properly grounded, grounding-type receptacle.
• The national electric code requires that a ground fault circuit interrupter (GFCI)
be used in the branch circuit supplying fountain pumps and other pond
equipment. See your electrical supplies dealer for this device.
• If the supply cable is damaged it can not be replaced and the pump unit should
be discarded.
WARNING: RISK OF FIRE
• Do not use with water above 30˚C.
• Do not pump flammable liquids.
3. Attach the pump to the connector tube on the fountain and place the pump inside
the fountain. Take the lamp and feed from the back of the fountain through the hole in the front and snap into clip.
WARNING:
Failure to do so will result in melting the cap and potentially damaging the light.
Attach the AC adapter jack to the base power cord. Both the wires from the pump and the
light should run through the notch on the back of the fountain. Connect the cable for light
to that AC adapter and tighten.
INSTRUCTIONS PERT
IMPORTANT SAFETY INSTRUCTIONS
LIGHTED LAMP
WARNING: TO REDUCE THE RISK OF FIRE OR INJURY TO PERSONS:
• Turn off/unplug and allow to cool before replacing lamp.
Lamp gets HOT quickly! Contact only switch/plug when
•
turning on.
• Keep lamp away from materials that may burn.
Do not touch the lamp at any time.
•
Use a soft cloth. Oil from skin may damage lamp.
•
Do not operate the luminaire fitting with a missing or
damaged shield.
Do not touch hot lens.
•
NOTE: Do not let pump run when NOT submerged in water. Doing so may damage the pump. Always submerge
the pump in water first, and then plug in the unit.
4. Fill base with distilled water to approximately 1/2" above pump. Use distilled water only. Tapwater will create mineral
deposits that will result in the corruption of the Waterfall and pump.
Ensure that the plastic cap housing the light for protection is taken off the bulb before plugging into outlet.
AINING TO A RISK OF FIRE, OR INJURY TO PERSONS
IS HOT!
10W
NOTICE: Do not place outdoors in weather conditions below 32˚F, may cause water to freeze.
5. Plug cord into 120V household outlet. Turn pump on to verify flow making sure it is not too high and everything is
operating correctly. Arrange river rocks on top of plate.
WARNING: This is not a toy. Keep out of reach of Children and Pets.
NOTE: Ensure that the electrical cord loop below the electrical outlet.” This will prevent water from running down
the cord into the electrical outlet.
MAINTAINING CLEANLINESS AND LIFE OF WATERFALL & PUMP
. Ensure water pump is kept clean and free of debris. We recommend
1
sing distilled water with this product.
u
Motorhead
NOTE: To clean pump, first make sure pump is UNPLUGGED
from 120V circuit and remove front plate. After removing the
front plate, the impeller holder must be removed. Remove the
impeller from the pump and check for debris and/or dirt. Rinse
impeller and pump under cold water. Reassemble.
Regulator
Impeller Holder
Front Plate
Seal Ring
Impeller
2. Periodically change water and clean the structure of the waterfall
with a mixture of vinegar and cold clean water.
3. Add water to waterfall periodically to keep water level at an optimum
Shaft
Suction Bracket
level (approximately 1/2” above pump) to avoid shortening the life of
the pump. Water level should completely cover pump at all times.
NOTE: Never let the pump run dry. This will shorten the life of the pump.
4. To store waterfall after use, unplug the waterfall from the electrical outlet, empty the water, and store in a cool dry
place.
TROUBLESHOOTING
1. If jets do not spray correctly, check water level and add if necessary or clean jet holes to unclog any deposits.
2. If pump fails to operate, check the circuit breaker, or try a different outlet to make sure the pump is getting electrical
power.
3. If the pump gurgles, spews, or “burps”, check the water level to make sure the pump has enough water to function.
4. If water is splashing outside of the waterfall, adjust the flow control valve to a lower setting.
LIMITED ONE YEAR WARRANTY
If within one (1) year from the date of purchase, this product fails due to a defect in material or workmanship, Intermatic Incorporated will
repair or replace it, at its sole option, free of charge. This warranty is extended to the original household purchaser only and is not
transferable. This warranty does not apply to: (a) damage to units caused by accident, dropping or abuse in handling, acts of God or any
negligent use; (b) units which have been subject to unauthorized repair, opened, taken apart or otherwise modified; (c) units not used in
accordance with instructions; (d) damages exceeding the cost of the product; (e) sealed lamps and/or lamp bulbs, LED’s and batteries; (f)
the finish on any portion of the product, such as surface and/or weathering, as this is considered normal wear and tear; (g) transit damage,
initial installation costs, removal costs, or reinstallation costs.
INTERMATIC INCORPORATED WILL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. SOME STATES DO NOT
ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR
EXCLUSION MAY NOT APPLY TO YOU. THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS OR IMPLIED WARRANTIES. ALL
IMPLIED WARRANTIES, INCLUDING THE WARRANTY OF MERCHANTABILITY AND THE WARRANTY OF FITNESS FOR A
PARTICULAR PURPOSE, ARE HEREBY MODIFIED TO EXIST ONLY AS CONTAINED IN THIS LIMITED WARRANTY, AND SHALL BE
OF THE SAME DURATION AS THE WARRANTY PERIOD STATED ABOVE. SOME STATES DO NOT ALLOW LIMITATIONS ON THE
DURATION OF AN IMPLIED WARRANTY, SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU.
This warranty service is available by either (a) returning the product to the dealer from whom the unit was purchased, or (b) mailing the
product, along with proof of purchase, postage prepaid to the authorized service center listed below
Incorporated/After Sales Service/7777 W
sure to wrap the product securely to avoid shipping damage.
inn Rd., Spring Grove, Illinois 60081-9698/815-675-7000 http://www
AUTHORIZED SER
Intermatic Incorporated
After Sales Service
7777 W
Spring Grove, IL
VICE CENTER
inn Road
60081-9698
This warranty is made by: Intermatic
.
.intermatic.com Please be
158WF12660