11
UNPACKING AND INSTALLATION
Although it is neither complicated to install nor difficult to operate your set. A few minutes of your time is required to read this manual for a properly wired installation and becoming familiar with its many features and how to use them. Please take great care in unpacking your set and do not discard the carton and other packing materials. They may be needed when moving your set and are required if it ever becomes necessary to return your set for service. Never place the unit near radiators, in front of heating vents, to direct sun light, in excessive humid or dusty location to avoid early damage and for your years of quality entertainment. Connect your complementary components as illustrated in the following page.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK.
DO NOT REMOVE COVER (OR BACK).
NO USER-SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
WARNING
To prevent fire or shock hazard, do not expose the unit to rain or moisture.
This symbol is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
This symbol is intended to alert the user to the presence of important operation and maintenance (servicing) instructions in the literature accompanying the appliance.
Caution: To prevent electric shock do not use this (polarized) plug with
an extension cord, receptacle or other outlet unless the blades can be fully inserted to prevent blade exposure.
Attentions: Pour prévenir les chocs électriques ne pas utiliser cette fiche
polarisée avec un prolongateur, une prise de courant on une autre sortie de courant, sauf si les lames peuvent étre insérées à fond sans en laisser aucune partie à découvert.
Page 3
FEATURES
This system controls 8 channel POWER.
This system provides stable power control with Micro Controller.
Reselecting channel is not necessary after power failure.
Maximum permissible current is 5A. It is appropriate for CCTV SYSTEM.
22
PRECAUTIONS
1. AVOID EXCESSIVE HEAT, DUST AND VIBRATION
Keep the unit away from locations where it is likely to be exposed to high temperatures or humidity–such as near radiators, stoves, etc. Also avoid locations which are subject to excessive dust accumulation or vibration which could cause mechanical damage.
2. VENTILATION
The unit has ventilation slots on the side and top panels. Do not block these vents.
3. AVOID PHYSICAL SHOCKS
Strong physical shocks to the unit can cause damage. Handle it with care.
4. DO NOT OPEN THE CASE OR ATTEMPT REPAIRS OR MODIFICATIONS YOURSELF
This product contains no user-serviceable parts. Refer all maintenance to qualified INTER-M service personnel. Opening the case and/or tampering with the internal circuitry voids the warranty.
5. ALWAYS POWER OFF BEFORE MAKING CONNECTIONS
Always turn the power OFF before connecting or disconnecting cables. This is important to prevent damage to the unit itself as well as other connected equipment.
6. HANDLES CABLES CAREFULLY
Always plug and unplug cables-including the AC power cord-by gripping the connector, not the cord.
7. CLEAN WITH SOFT DRY CLOTH
Never use solvents such as venzine or thinner to clean the unit. Wipe clean with a soft, dry cloth.
Page 4
33
VPC-1108 POWER CONTROLLER
POWERONOFF12345678
AC INPUT 220V,50Hz
~
GND12345678
FRONT/REAR PANEL CONTROLS
1
3 4
2
5
1. POWER SWITCH
This switch turns the VPC-1108’s power supply on and off. And the power LED will light when the POWER is ON.
2. CHANNEL SELECT BUTTON
These buttons are used to select the channel you want to.
3. AC INLET
This terminal is connected with AC input cord.
4. GND
The unit is connected to the Earth through this terminal.
5. OUTPUT TERMINAL
These terminals are for main power output. The POWER is selected by pressing the channel select button at front panel and is the same power as input.
Page 5
HOW TO USE
AC INPUT 220V,50Hz
~
GND12345678
44
1. Connect the power cord.
2. Turn the POWER ON.
3. Select the channel you want to use at front panel, then the POWER is delivered to CCTV equipment.
4. It is not necessary to reselect channel after POWER FAILURE, because this unit remember the channel used before.
5. The used channel before POWER FAILURE are turned ON in sequence by the 20msec when you turn the POWER ON.
6. Whenever you press the Channel Select Button, it will be selected and released alternately.
7. Don’t use above permissible current. (8 channel total 5A)
Page 6
55
SPECIFICATIONS
ELECTRICAL
Output Voltage....................................................................................................the same as Input Voltage
Fuse Rating ........................................................................................................F1: 5A/250V (T5AL 250V)
F2: 2A/250V (T2AL 250V)
Environment ...............................................................................................................0~40ºC, 30~90% RH
GENERAL
Power Source.......................................................................................................AC 100V~230V, 50/60Hz
Power Consumption ............................................................................................................................6.5W
Weight.................................................................................................................................................3.8kg
Dimensions .....................................................................................................482(W) 44(H) 350(D)mm
*Specifications and appearance are subject to change without notice for improvement.
Page 7
MADE IN KOREA
Loading...